• 제목/요약/키워드: Electrical Resistivity & conductivity

검색결과 314건 처리시간 0.021초

온도 의존성 물성치를 가지는 유한한 전도층에서의 전기/열하중을 받는 균열의 해석 (Electrothermal Crack Analysis in a Finite Conductive Layer with Temperature-dependent Material Properties)

  • 장용훈;이상영
    • 대한기계학회논문집A
    • /
    • 제30권8호
    • /
    • pp.949-956
    • /
    • 2006
  • The method of Greenwood and Williamson is extended to obtain a solution to the coupled non-linear problem of steady-state electrical and thermal conduction across a crack in a conductive layer, for which the electrical resistivity and thermal conductivity are functions of temperature. The problem can be decomposed into the solution of a pair of non-linear algebraic equations involving boundary values and material properties. The new mixed-boundary value problem given from the thermal and electrical boundary conditions for the crack in the conductive layer is reduced in order to solve a singular integral equation of the first kind, the solution of which can be expressed in terms of the product of a series of the Chebyshev polynomials and their weight function. The non-existence of the solution for an infinite conductor in electrical and thermal conduction is shown. Numerical results are given showing the temperature field around the crack.

P형 Bi0.5Sb1.5Te3 박막의 열전 특성에 미치는 두께 및 어닐링 효과 (Thickness and Annealing Effects on the Thermoelectric Properties of P-type Bi0.5Sb1.5Te3 Thin Films)

  • 김일호;장경욱
    • 한국재료학회지
    • /
    • 제14권1호
    • /
    • pp.41-45
    • /
    • 2004
  • P-type $Bi_{0.5}$$Sb_{1.5}$ $Te_3$ thin films were deposited by the flash evaporation technique, and their thermoelectric properties and electronic transport parameters were investigated. The effective mean free path model was adopted to examine the thickness effect on the thermoelectric properties. Annealing effects on the carrier concentration and mobility were also studied, and their variations were analyzed in conjunction with the antisite defects. Seebeck coefficient and electrical resistivity versus inverse thickness showed a linear relationship, and the effective mean free path was found to be 3150$\AA$. No phase transformation and composition change were observed after annealing treatment, but carrier mobility increased due to grain growth. Carrier concentration decreased considerably due to reduction of the antisite defects, so that electrical conductivity decreased and Seebeck coefficient increased. When annealed at 473 K for 1 hr, Seebeck coefficient and electrical conductivity were $160\mu$V/K and 610 $W^{-1}$ $cm^{ -1}$, respectively. Therefore, the thermoelectric quality factor were also enhanced to be $16\mu$W/cm $K^2$.>.

연속주조된 Cu-Ni-Si계 합금의 특성평가 (Characterization of Continuous Cast Cu-Ni-Si Alloys)

  • 이정일;조훈
    • 열처리공학회지
    • /
    • 제25권6호
    • /
    • pp.292-298
    • /
    • 2012
  • In this study, Cu-2.5at.%Ni-1at.%Si alloys were fabricated by horizontal continuous casting system to improve the electrical conductivity and mechanical properties of Cu-Ni-Si alloy. Withdrawing speed was changed with 50, 100, 150 and 200 mm/min for the optimum manufacturing condition. Microstructure was observed using OM, FE-SEM and TEM. Electrical conductivity was measured by 4-point probe method and mechanical properties were tested. A horizontal continuous cast thin slab had sound macro and micro structures with partly crystallized structures. Electrical resistivity decreased with increasing annealing temperature from 250 to $850^{\circ}C$, with increasing annealing temperature The maximum hardness and tensile strength were Hv 130, 610 MPa at $550^{\circ}C$, respectively. With changing withdrawing speed from 50 to 150 mm/min, hardness, tensile strength, yield strength and elongation were Hv 60-65, 210-230 MPa, 65-75 MPa and 40-50%, respectively.

ZnO 박막의 전기적 구조적 특성에 미치는 수소 분압비의 영향 (Effect of Hydrogen Partial Pressure Ratio on Electrical and Structural Properties of ZnO Thin Film)

  • 이성훈;신민근;변응선;김도근;전상조;구본흔
    • 한국표면공학회지
    • /
    • 제39권6호
    • /
    • pp.250-254
    • /
    • 2006
  • Effect of hydrogen partial pressure ratio on the structural and electrical properties of highly c-axis oriented ZnO films deposited by oxygen ion-assisted pulsed filtered vacuum arc at a room temperature was investigated. The hydrogen partial pressure ratio were $1.4%\sim9.8%$ at 40% oxygen pressure ratio. The conductivity of ZnO:H films was increased from 1.4% up to 4.2% due to relatively high carrier mobility caused by improvement of crystallinity While the conductivity of ZnO:H films were decreased over than 4.2% and (0002) orientation was also deteriorated. The lowest resistivity of ZnO:H films was $2.5{\times}10^{-3}\;{\Omega}{\cdot}cm$ at 4.2% of hydrogen pressure ratio. Transmittance of ZnO:H films in visible range was 85% which is lower than that of undoped ZnO films because of declined preferred orientation.

탄화온도가 탄화보드의 열전도율 및 전기적 성질에 미치는 영향 (Effect of Carbonization Temperature on the Thermal Conductivity and Electric Properties of Carbonized Boards)

  • 오승원;박상범;김종인;황정우
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권1호
    • /
    • pp.58-63
    • /
    • 2013
  • 탄화보드의 실용화를 위한 기초연구로 중밀도섬유판, 파티클보드, 합판 및 물푸레나무 목재를 $400{\sim}1,100^{\circ}C$로 탄화하여 탄화온도에 따른 열전도율 및 전기적 성질을 측정하였다. 열전도율은 탄화 파티클보드의 탄화온도가 $900^{\circ}C$일 때 0.1326 m/k로 가장 우수하였으며, 전반적으로 탄화보드의 밀도가 클수록 열전도율이 빨랐다. 비저항값은 탄화온도가 높을수록 감소하여 탄화온도 $1,000^{\circ}C$ 이후에는 거의 도체에 가까운 값을 나타냈다. 높은 전압으로 탄화보드에 전기를 통했을 때 전류와 전력은 증가하였으며 표면온도가 높았다.

YBCO 박막형 초전도 한류기에 적용 가능한 전류리드 제작방안 (A Device of Current Lead for Fault Current Limiter of YBCO Film)

  • 박권배;강종성;이방욱;오일성;김혜림;현옥배
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.219-220
    • /
    • 2002
  • In this paper, we propose non-soldered current lead was introduced which has low contact resistivity for fault current limiters of YBCO film. Carbon/Cu has good thermal conductivity, electrical conductivity and chemically stable, and so forth. Therefore it seems to be suitable material of current lead for current limiters of YBCO film. We have investigated electric field-current in field of 0-130 mT and quench characteristics of a YBCO film. Experimental results show that characteristics of transport is all right using Carbon/Cu-current lead.

  • PDF

화학증착법에 의해 제조된 Sb-doped $SnO_2$ 박막의 전기적 및 광학적 특성 (Electrical and Optical Properties of Sb-doped SnO2 Films Prepared by Chemical Vapor Deposition)

  • 이수원;김광호
    • 한국세라믹학회지
    • /
    • 제29권4호
    • /
    • pp.319-327
    • /
    • 1992
  • Sb-doped SnO2 films were formed on Corning glass 7059 substrate by chemical vapor deposition using simulataneous hydrolysis of SnCl4 and SbCl5. Fairly good transparent conducting film with a low resistivity of ~6$\times$10-4{{{{ OMEGA }}cm and high average optical transparency above ~85% in the range of visible light was obtained at the deposition condition of 50$0^{\circ}C$ and input-gas ratio, [Psbcl5/Psncl4] of 0.05. Film conductivity was improved without loosing optical transparency at light doping of Sb and found to be due to the increase of electron concentration. However, high doping of Sb into SnO2 film largely deteriorated conductivity, optical transparency and crystallinity of the film.

  • PDF

저온에서 La2/3+xTiO3-δ (x = 0, 0.13)세라믹스의 전자전도특성 (Low-Temperature Electron Transport Properties of La2/3+xTiO3-δ (x = 0, 0.13))

  • 정우환
    • 한국재료학회지
    • /
    • 제24권11호
    • /
    • pp.604-609
    • /
    • 2014
  • The thermoelectric power and dc conductivity of $La_{2/3+x}TiO_{3-{\delta}}$ (x = 0, 0.13) were investigated. The thermoelectric power was negative between 80K and 300K. The measured thermoelectric power of x = 0.13 increased linearly with increased temperatures and was represented by $S_0+BT$. The x = 0 sample exhibited insulating behavior, while the x = 0.13 sample showed metallic behavior. The electric resistivity of x = 0.13 had a linear temperature dependence at high temperatures and a T3/2 dependence below about 100K. On the other hand, the electric resistivity of x = 0 has a linear relation between $ln{\rho}/T$ and 1/T in the range of 200 to 300K, and the activation energy for small polaron hopping was 0.23 eV. The temperature dependence of thermoelectric power and the resistivity of x = 0 suggests that the charge carriers responsible for conduction are strongly localized. This temperature dependence indicates that the charge carrier (x = 0) is an adiabatic small polaron. These experimental results are interpreted in terms of spin (x = 0.13) and small polaron (x = 0) hopping of almost localized Ti 3d electrons.

불량 매립지 오염평가를 위한 지구물리 탐사 사례연구 (Environmental Geophysical Survey of Abandoned Landfills for Contamination Evaluation: A Case Study)

  • 이성순;이진용;윤희성;이강근;김창균;유영철
    • 대한환경공학회지
    • /
    • 제28권5호
    • /
    • pp.463-471
    • /
    • 2006
  • 본 연구에서는 충남 천안시와 강원도 원주시에 위치한 불량매립지 일대에 대해 지구물리 탐사 중 전기비저항 탐사를 실시하였으며, 수집된 자료를 이용하여 2차원과 3차원 비저항 역산 모델링을 수행하여 매립지 주변 지질구조와 침출수 오염영역, 침출수 유동을 평가하였다. 천안 직산매립지는 매립지가 논 상부에 위치하고 있으며 매립지로부터 침출수로 인한 농지 오염의 가능성이 있어 물리탐사 측선 배열을 매립지를 기준으로 서로 교차하는 측선배열을 수행하였다. 원주 매립지의 경우 매립지와 주변 논밭의 경계가 매립지 옹벽으로 나뉘며, 매립지 경계로부터 침출수 침전시설이 위치하고 있으나 현재는 방치된 상태로 침출수 누출로 인한 농지 오염의 가능성이 있다. 이에 총 4개 측선에 대해 3개 측선은 매립지 경계로부터 일정거리를 두고 평행하게 배열을 하였으며, 나머지 한 개 측선은 이 3개 측선을 교차하도록 배열하였다. 2차원 비저항 역산모델을 수행한 결과 천안매립지의 경우 침출수가 외부 논으로 확대되지 않고 매립지 내부에 정체된 형태로 존재하는 것으로 평가되었다. 이는 지하수 관측정 정기 수질분석시 측정된 지하수의 전기전도도 값의 분포에서도 확인할 수 있다. 원주 매립지의 경우는 매립지로부터 유래된 침출수가 매립지 경계 부근 폐기된 침출수 처리시설 밑으로 흐르는 것으로 평가되었고, 매립지 주변 기존 저수지였던 곳에서는 매립지 주변에 위치한 계곡의 영향으로 계곡에서 흘러드는 지하수에 의한 흐름과 과거 저수지의 영향으로 지표 근처에서 낮은 비저항대를 형성하는 것을 확인할 수 있었다. 또한 저수지 제방에서는 하부 $7{\sim}8m$ 심도에서 지하수가 논으로 유입되는 것으로 추정되었다. 이하의 반응온도 기준으로 약 $10{\sim}80%$ 이상이었다. 따라서, CVOCs 제거반응을 위하여 널리 사용되고 있는 단일 $CrO_x/Al_2O_3$ 촉매보다는 $CrO_x$의 사용량을 최소화하면서도 우수한 반응활성을 얻을 수 있는 $CrO_x/TiO_2$-based복합 산화물 촉매가 보다 바람직하며 하나의 대안적인 촉매 디자인 방법으로 응용될 수 있을 것으로 생각된다.EX>을 효과적으로 처리할 수 있었다.문에, 이 연구에서 개발된 수치모델은 퇴적물에서 일어나는 미량 오염 물질의 거동을 파악하기 위해 유용하게 사용되어질 수 있을 것으로 사료된다.

제주도 쓰레기매립장 침출수 조사를 위한 전기 및 소형루프 전자탐사의 적용 (Application of Electrical and Small-Loop EM survey to the Identification of the Leachate at a Waste Landfill in Jeiu Island)

  • 송성호;용환호;안중기;김기표
    • 지구물리와물리탐사
    • /
    • 제6권3호
    • /
    • pp.143-152
    • /
    • 2003
  • 쓰레기매립장의 침출수 누출 탐지를 위한 물리탐사법은 침출수의 전기전도도를 대상으로 한 전기탐사법이 주로 적용되어 왔다. 이 연구에서는 제주도에 위치한 비위생매립지를 대상으로 전기비저항 탐사와 더불어 매립장 경계부와 토양층을 통한 침출수 누출 영역을 효율적으로 규명하기 위하여 다중주파수를 이용한 소형루프 전자탐사를 수행하였으며, 아울러 오염지역의 천부 지하수 유동 방향을 추정하기 위하여 침출수의 유동에 의해 발생될 수 있는 자연전위를 모니터링 하였다. 전기비저항 탐사 및 자연전위 모니터링 결과 매립지 주변을 통한 침출수의 누출 가능성은 거의 없는 것으로 나타났으며, 이는 주변 하천에서 정기적으로 실시한 수질 분석 결과와 일치된다. 또한 소형루프 전자탐사 자료에 대하여 공간 필터링 및 1차원 역산법을 적용한 결과 매립장 경계부의 위치 및 매립장 내부의 심도별 매립물에 의한 저비저항 이상대를 효과적으로 도출 할 수 있었다.