• Title/Summary/Keyword: Electrical Pole

Search Result 1,094, Processing Time 0.029 seconds

Sensitivity Analysis of Geometrical Parameters of a Switched Reluctance Motor with Modified Pole Shapes

  • Balaji, M.;Ramkumar, S.;Kamaraj, V.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.136-142
    • /
    • 2014
  • A major problem in Switched Reluctance Motor (SRM) is torque ripple, which causes undesirable acoustic noise and vibration. This work focuses on reducing the undesirable torque ripple in SRM by modifying stator and rotor geometry. This paper presents a comparative study on torque ripple minimization in SRM with modified pole shapes such as stator pole taper, stator pole face with non-uniform air gap and pole shoe attached to rotor pole. Further this paper presents a detailed sensitivity analysis of the effect of different geometrical parameters that alter the pole face shapes on the performance of SRM. The analysis is performed using finite-element method considering average torque and torque ripple as performance parameters. Based on the analysis, a design combining stator pole taper with non-uniform air gap is proposed to improve the torque characteristics of SRM. The dynamic characteristics of the proposed design are simulated and the results show satisfactory reduction in torque ripple.

The Fundamental Design Consideration of Salient Pole Rotor Type Single Phase SRM

  • Oh, Young-Woong;Lee, Eun-Woong;Kim, Jun-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.2
    • /
    • pp.22-27
    • /
    • 2001
  • Salient pole rotor type single phase switched reluctance motor is of simple and rigid structure, short shaft and simple driving circuit. Especially, the output power per unit volume of salient pole rotor structure is comparatively high because the magnetic fluxes of axial and radial direction are simultaneously used. Therefore, this motor will be used at small space and difficult maintenance situations. In this paper, the selecting method of proper pole arc, stator, and rotor dimension of salient pole rotor type single phase SRM is proposed.

Design of Salient Pole Rotor Type Single Phase SRM

  • Oh, Young-Woong;Lee, Eun-Woong;Kim, Jun-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.2
    • /
    • pp.9-14
    • /
    • 2001
  • Because salient pole rotor type single phase SRM(Switched Reluctance Motor) has a simple structure and can be use both radial and axial direction magnetic flux at the same time, its output power per unit volume is high. Therefore, the shaft length can be minimized when compared with same output motors. However, salient pole rotor is hard to design due to its complex magnetic circuit. In this paper, salient pole rotor type single phase SRM with minimized shaft length is designed and selected the most suitable dimension of rotor, stator, pole arc and salient pole.

A Study of Initial Pole Position Estimation for Interior Permanent Magnet Motor (매입형 영구자석 전동기의 초기 극위치 추정에 관한 연구)

  • Park, Chang-Soo;Lee, Geun-Ho;Nam, Hyuk;Lee, Ji-Young;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.955-957
    • /
    • 2003
  • In this paper deal with Initial Pole Position Estimation for Interior Permanent Magnet Motor. Generally, Brushless motor is considered Initial Pole Position with absolute encoder or resolver, etc. In the motor, the flux from the magnets is large enough to saturate the stator iron, results in different inductance values along the pole position. Based upon the relationship between magnitude of inductance and the resultant magnetic filed, initial pole position is estimated at standstill without position sensors, especially, this paper provide the direction of the magnetization. Finally, analysis results are presented to confirm ability of initial pole position estimation.

  • PDF

Pole Position Detection Method by Using Pole and Character Recognition (전철주 및 문자 인식을 이용한 시설물 절대위치 검지 방법)

  • Choi, Woo-Yong;Park, Jong-Gook;Lee, Byeong-Gon;Joo, Yong-Hwan;Han, Seung-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.704-710
    • /
    • 2016
  • In this paper, we proposed pole position detection system for providing exact location information to users. The proposed system consists of pole recognition part and pole number recognition part. Above all, exact pole recognition is carried out by PDD(Pole Detection Device). And recognition of pole number is performed by PID(Pole Inspection Device). Acquired image by using line scan camera is judged whether it is free bracket or not through image processing. When it is judged as free bracket, pole number image is acquired by OCR camera and recognized by OCR. By recognizing pole number, exact location information is provided to user.

Characteristic of Moving Coil type Linear Oscillatory Actuator by Multi-Pole Permancent Magnet Arrangement (영구자석 다극 배치에 의한 가동 코일형 리니어 진도 엑츄에이터의 특성)

  • 김덕현;강규홍;홍정표;김규탁
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.273-281
    • /
    • 2001
  • In order to overcome the demerit and to improve the operation characteristics of Moving Coil type Linear Oscillatory Actuator(MC-LOA) with single-pole permanent magnet, this paper presents two models having the balanced magnetic circuit by multi-pole permanent magnet. They are short coil type with two-pole single-sided and two-ple double-sided permanent magnet. The characteristics between single-pole and multi-pole permanent magnet type MC-LOA are compared. As a result, multi-pole type MC-LOA has more merits than single-pole type about operation characteristics improvement and machine volume. The characteristics analysis is performed by their dynamic analysis composed of kinetic and electric equations and Finite Element Method(FEM). The propriety of multi-pole type MC-LOA model is verified with analysis results.

  • PDF

A Study on the Protect Measures and Impact of Electric Pole for Abnormal Tension of Messenger Wire (조가선 이상 장력 작용에 대한 전주의 영향 및 보호 대책 연구)

  • Oh, Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.78-83
    • /
    • 2006
  • In this study, we analyzed the influence or electrical pole by FEM(Finite Element Method) and developed protective system by designing and interpreting protective system for electrical pole when abnormal strength worked on messenger wire. Protective system did not shed messenger wire under wind pressure and discontent load but did assign a part to preventing rupture of electrical pole through automatically shed messenger wire over fred strength. Structure of protective system analysis by FEM and prove property by measuring tensile strength for practical product.

Safety Inspection of Sea Dike in Reclamation Project Area Using Electrical and Electromagnetic Survey (전기, 전자탐사법을 이용한 간척개발 사업지구 내 방조제 안전점검)

  • Song, Seong-Ho;Seong, Baek-Uk;Kim, Yeong-Gyu
    • KCID journal
    • /
    • v.13 no.2
    • /
    • pp.254-261
    • /
    • 2006
  • We applied electrical resistivity survey using modified pole-pole array and small-loop electromagnetic survey to delineate the zone of seawater inflow through a tide embankment. The tide embankment is generally affected by tidal variation and has low resistivity characteristic due to the high saturation of seawater. For this reason, the electrical resistivity survey using modified pole-pole array, which is relatively more effective to the conductive media, was carried out to detect the inflow zone of seawater and small-loop electromagnetic survey using multi-frequency with 300 to 20,010 Hz was conducted. As a result of both electrical resistivity survey using modified pole-pole array and small -loop electromagnetic survey, these survey methods are found to be quite effective for investigation of seawater inflow zone in the sea dike.

  • PDF

A CCM Interleaved Totem-pole Boost Bridgeless Power Factor Correction Circuit (전류 연속 모드로 구동이 가능한 Interleaved Totem-Pole 부스트 역률 보상 회로)

  • Yi, Je-Hyun;Jang, Paul;Kang, Sang-Woo;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.33-34
    • /
    • 2015
  • Totem-pole 역률 보상 회로는 스위치 body diode의 reverse-recovery 문제로 인해 전류 불연속 모드 혹은 임계 도통 모드로 동작 시키는 것이 일반적이다. 본 논문에서는 전류 연속 모드로 동작이 가능한 새로운 interleaved totem-pole 역률 보상 회로를 제안한다. 제안하는 interleaved totem-pole 역률 보상 회로는 각 스위치 leg 사이에 보조 인덕터를 연결함으로써 스위칭 시에 body diode에 흐르는 전류를 없애 전류 연속모드로 동작이 가능하다. 또한 보조 인덕터로 인해 스위치의 영 전압 스위칭도 가능하게 된다. 제안하는 interleaved totem-pole 역률 보상 회로는 시뮬레이션을 통하여 검증하였다.

  • PDF

Application of SP and Pole-pole Array Electrical Resistivity Surveys to the Seawater Leakage Problem of the Embankment (방조제 누수지점 탐지를 위한 SP및 단극배열 전기비저항탐사의 적용)

  • 송성호;이규상;김진호;권병두
    • Economic and Environmental Geology
    • /
    • v.33 no.5
    • /
    • pp.417-424
    • /
    • 2000
  • We applied SP monitoring and resistivity surveys using the pole-pole electrode array to seawater leakage problems in the Youngsan estuary dam and the Eoeun embankment to estimate and detect the zone of seawater leakage. The embankment is generally affected by tidal variation and has low resistivity characteristics due to the high saturation of seawater. For this reason, SP monitoring and the pole-pole array resistivity surveys, which are relatively more effective to the conductive media, were carried out to delineate the leakage zones of sea water through the embankment. We checked out electrical conductivity (EC) and temperature variations along the inner part of Youngsan estuary dam to detect the zone of seawater leakage and found that the measured EC value agreed to that of seawater in the leakage zone and the temperature was lower than that of the vicinity of leakage zone. SP monitoring results were coincided with tidal variations at each embankment. At the leakage zones in the Youngsan estuary dam and the Eoeun embankment, SP anomalies are in the range of -60~-85 mV and -20~-50 mV, respectively, and true resistivity values obtained by 2-D inversion are 3~15 ohm-m and below 0.3 ohm-m, respectively. Both SP monitoring and the pole-pole array resistivity method are found to be quite effective for investigation of seawater leakage zones in the embankment.

  • PDF