• 제목/요약/키워드: Electrical Particle Charging

검색결과 31건 처리시간 0.024초

스왐기반 퍼지시스템을 이용한 코크오븐 연소제어 모델링 (A combustion control modeling of coke oven by Swarm-based fuzzy system)

  • 고언태;황석균;이진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.493-495
    • /
    • 2005
  • This paper proposes a swarm-based fuzzy system modeling technique for coke oven combustion control diagnosis. The coke plant produces coke for the blast furnace plant in steel making process by charging coal into oven and supplying gas to carbonize it. A conventional mathematical model for coke oven combustion control has been used to control the amount of gas input, but it does not work well because of highly nonlinear feature of coke plant. To solve this problem, swarm-based fuzzy system modeling technique is suggested to construct a diagnosis model of coke oven combustion control. Based on the measured input-output data pairs, the fuzzy rules are generated and the parameters are tuned by the PSO(Particle Swarm Optimizer) to increase the accuracy of the fuzzy system is operated. This system computes the proper amount of gas input taking the operation conditions of coke oven into account, and compares the computed result with the supplied gas input.

  • PDF

DBD(Dielectric Barrier Discharge)에 의해 하전된 나노입자의 양극성 대전량 분포 (Bipolar Charge Distribution of Nano Particles Passing through the Dielectric Barrier Discharge Reactor)

  • 지준호;강석훈;변정훈;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1684-1689
    • /
    • 2003
  • Dielectric Barrier Discharges (DBD) in oxygen and air are well established for the production of large quantities of ozone and are more recently being applied to a wider range of after treatment processes for HAPs(Hazardous Air Pollutants). The potential use as a charger for particle collection are not well known. In this work, we measured charge distribution of nanometer or submicron sized particles passing through the dielectric barrier discharge reactor. The bipolar charge characteristics of particles passing DBD reactor were investigated. Fluorometric method using uranine particles and a fluorometer was employed to examine the bipolar charging characteristics of the charged particles by DBD reactor. Finally, the charge distributions of particles were determined from the electrical mobility classification using DMA.

  • PDF

실시간 에어로졸 측정장비를 이용한 대기 중 입자상 물질의 무게 농도 분포의 추정 (Estimation of Mass Size Distribution of Atmospheric Aerosols Using Real-Time Aerosol Measuring Instruments)

  • 지준호;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.39-50
    • /
    • 2013
  • SMPS, APS, ELPI는 실시간으로 대기 중 입자상 물질을 측정할 수 있는 장비로 많은 연구자들에 의해 사용되고 있다. 하지만 측정장비의 특성과 입자 분류 특성에 대한 충분한 이해가 없다면, 단순히 장비에 제공된 소프트웨어의 계산 결과를 여과 없이 그대로 사용할 수밖에 없다. 본 연구에서는 SMPS, APS, ELPI의 측정 메커니즘을 간단히 정리하였고, 전기적 이동도로 입자를 분리하는 SMPS와 공기역학적 거동을 이용하는 APS를 함께 사용하여 입자의 크기분포를 측정할 때 발생할 수 있는 문제점을 고찰하였다. 크기분포 측정결과를 이용해서 무게 농도를 환산하는 과정에서 대기 입자의 입경에 따른 밀도 정보를 제공하는 것이 매우 중요하다는 것을 보였다. 특히, APS 측정결과를 이용하는 경우 무게 농도의 추정 결과가 크게 영향을 받았다. ELPI의 경우 입자 밀도를 정확히 설정하지 않으면 입자의 수 농도에 오차가 크게 발생할 수 있으므로, 정확한 밀도를 설정하는 것이 중요했다. 반면에 ELPI로 대기 중입자상 물질의 무게 농도를 추정하는 경우 밀도가 실제와 다르게 설정되더라도 공기역학적 입경으로 나타내면 총 무게 농도는 수 농도에 비해 상대적으로 영향이 적었다. 향후 SMPS와 APS를 이용하여 시간에 따른 크기 분포 변화와 연간 수 농도와 무게 농도의 변화 추이를 측정하는 연구가 필요하다. 특히, 국내 대기 중입자의 입경에 따른 평균 밀도 혹은 유효 밀도를 측정하여 크기분포와 총 수 농도 혹은 PM2.5나 PM1에 해당하는 무게 농도를 정확하게 계산할 수 있는 데이터 환산 프로그램의 개발도 필요하다. 이와 같은 연구로 시간경과에 따라 변화하는 대기 입자의 오염원에 대한 영향을 규명하는 기초 자료를 얻을 수 있을 것이다.

Electrostatic Charging and Substrate Seeding in Gas Phase Synthesis of Nanocrystalline Diamond Powder

  • Cho, Jung-Min;Lee, Hak-Joo;Choi, Heon-Jin;Lee, Wook-Seong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.418-418
    • /
    • 2012
  • Synthesis of nanocrystalline diamond powder was investigated via a gas-to-particle scheme using the hot filament chemical vapor deposition. Effect of substrate surface seeding by nano diamond powder, and that of the electrical conductance of the substrate were studied. The substrate temperature, methane content in the precursor gas, filament-substrate distance and filament temperature were $670^{\circ}C$, 5% methane in hydrogen, 10 mm and $2400^{\circ}C$, respectively. The powder formation by gas-to-particle mechanism were greatly enhanced by the substrate seeding by the nano diamond powder. It was attributed to the removal of the electrostatic force between the substrate and the seeded nano diamond particle by the thermal electron shower from the hot filament, via the depolarization of the substrate surface or the attached diamond powder and subsequent levitation into the gas phase to serve as the gas-phase nucleation site. The powder formation was greatly favoured by the conducting substrate relative to the insulating substrate, which proved the actual effect of the electric static force in the powder formation.

  • PDF

에어로졸 중화기의 성능이 고하전 입자의 크기분포 측정에 미치는 영향 (Effect of Performance of Aerosol Charge Neutralizers on the Measurement of Highly Charged Particles Using a SMPS)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1498-1507
    • /
    • 2003
  • A SMPS(scanning mobility particle sizer) system measures the number size distribution of particles using electrical mobility detection technique. An aerosol charge neutralizer, which is a component of the SMPS, is a bipolar charger using a radioactive source to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. In this study, the effect of the particle charging characteristics of two aerosol charge neutralizers on the measurement using a SMPS system was experimentally investigated for highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0.5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.3 to 3.0 L/min. The results show that the non-equilibrium character in particle charge distribution appears as the air flow rate increases although the particle number concentration is relatively low in the range of 1.5∼2x10$^{6}$ particles/㎤. The low neutralizing efficiency of the $^{85}$ Kr aerosol charge neutralizer for highly charged particles can cause to bring an artifact in the measurement using a SMPS system. However, the performance of the $^{210}$ Po aerosol charge neutralizer is insensitive to the air flow rate.

Gerdien 이온측정기를 이용한 에어로졸의 하전 특성 분석에 관한 연구 (Study on electrical charge distribution of aerosol using a Gerdien ion counter)

  • 조윤행;심준목;신일경;육세진;박현설
    • 한국입자에어로졸학회지
    • /
    • 제14권1호
    • /
    • pp.17-24
    • /
    • 2018
  • Since the motion of the charged particle strongly depends on its charge characteristics, information on charge distributions of target particles is one of the important variables in aerosol research. In this study, charged distribution of atomized NaCl particles were measured using a Gerdien type ion counter. Two kinds of particle charging conditions were used in this study. First, atomized NaCl particles were passed through an aerosol neutralizer to have a Boltzmann charge distribution, and then its charge distribution was measured. In this case, the portion of uncharged particles was compared with the portion obtained from the Boltzmann charge distribution for verifying the suggested experimental method. Second, same experiment was conducted without the aerosol neutralizer to measure the charge distribution of atomized and un-neutralized NaCl particles. In the conclusion, the portion of uncharged, negatively charged and positively charged particles were 19%, 62% and 20%, respectively, for neutralized particles. The atomized particles, which was generated without the aerosol neutralizer, also had almost a zero charge state, but the standard deviation in charge distribution was larger than that of neutralized particles. The test method proposed in this study is expected to be used in various aerosol research fields because it can obtain simple information on the particle charge characteristics more easily and quickly than the existing test methods.

Fault Diagnosis of Transformer Based on Self-powered RFID Sensor Tag and Improved HHT

  • Wang, Tao;He, Yigang;Li, Bing;Shi, Tiancheng
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.2134-2143
    • /
    • 2018
  • This work introduces a fault diagnosis method for transformer based on self-powered radio frequency identification (RFID) sensor tag and improved Hilbert-Huang transform (HHT). Consisted by RFID tag chip, power management circuit, MCU and accelerometer, the developed RFID sensor tag is used to acquire and wirelessly transmit the vibration signal. A customized power management including solar panel, low dropout (LDO) voltage regulator, supercapacitor and corresponding charging circuit is presented to guarantee constant DC power for the sensor tag. An improved band restricted empirical mode decomposition (BREMD) which is optimized by quantum-behaved particle swarm optimization (QPSO) algorithm is proposed to deal with the raw vibration signal. Compared with traditional methods, this improved BREMD method shows great superiority in reducing mode aliasing. Then, a promising fault diagnosis approach on the basis of Hilbert marginal spectrum variations is brought up. The measured results show that the presented power management circuit can generate 2.5V DC voltage for the rest of the sensor tag. The developed sensor tag can achieve a reliable communication distance of 17.8m in the test environment. Furthermore, the measurement results indicate the promising performance of fault diagnosis for transformer.

정전선별법을 이용한 석탄회로부터 미연탄소분 제거에 관한 연구

  • 최우진;염영길
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.97-105
    • /
    • 1998
  • The goal of this study is to investigate the potential application of triboelectrostatic separation process for removing unburned carbon from fly ash. The process utilizes the difference in electrical charging characteristics between the organic material (carbon) and the mineral matter (fly ash). In the present work, dry separation tests have been conducted on Samchunpo fly ash samples using a bench - scale analytic separator. The test variables studied include air rate, feed rate, electric field strength, particle size, charger material and length, etc. The best separation results were obtained at the air rate 501/min, feed rate 15 g/min and voltage 15 ㎸. The fly ash with carbon content below 1 % was obtained with over 65% recovery.

  • PDF

Corona Discharge Characteristics and Particle Losses in a Unipolar Corona-needle Charger Obtained through Numerical and Experimental Studies

  • Intra, Panich;Yawootti, Artit;Rattanadecho, Phadungsak
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.2021-2030
    • /
    • 2017
  • In this paper, the unipolar corona-needle charger was developed and its capabilities were both numerically and experimentally investigated. The experimental corona discharges and particle losses in the charger were obtained at different corona voltage, aerosol flow rate and particle diameter for positive and negative coronas. Inside the charger, the electric field and charge distribution and the transport behavior of the charged particle were predicted by a numerical simulation. The experimental results yielded the highest ion number concentrations of about $1.087{\times}10^{15}ions/m^3$ for a positive corona voltage of about 3.2 kV, and $1.247{\times}10^{16}ions/m^3$ for a negative corona voltage of about 2.9 kV, and the highest $N_it$ product for positive and negative coronas was found to about $7.53{\times}10^{13}$ and $8.65{\times}10^{14}ions/m^3$ s was occurred at the positive and negative corona voltages of about 3.2 and 2.9 kV, respectively, and the flow rate of 0.3 L/min. The highest diffusion loss was found to occur at particles with diameter of 30 nm to be about 62.50 and 19.33 % for the aerosol flow rate of 0.3 and 1.5 L/min, respectively, and the highest electrostatic loss was found to occur at particles with diameters of 75 and 50 nm to be about 86.29 and 72.92 % for positive and negative corona voltages of about 2.9 and 2.5 kV, respectively. The numerical results for the electric field distribution and the charged particles migration inside the charger were used to guide the description of the electric field and the behavior of charged particle trajectories to improve the design and refinement of a unipolar corona-needle charger that otherwise could not be seen from the experimental data.

전기영동 디스플레이에서 전자 잉크의 전류 특성 및 평가 (Current Properties and Evaluation of Electronic Ink in Electrophoretic Display)

  • 안형진;김영조
    • 한국전기전자재료학회논문지
    • /
    • 제33권1호
    • /
    • pp.31-36
    • /
    • 2020
  • An investigation was conducted to determine whether the ratio of the fluid to the charged particles affects the panel reflexibility rate and the drifting current flowing in the panel, in electrophoretic-based electronic paper. In this regard, three panels were produced in this study with the ratio of the charged particles to the fluid set as 1:5, 1:1, and 5:1. Each sample was driven using an identical input pulse, for which the current flowing in the panel and the output voltage of the photodiode were measured for the panel reflexibility rate. Consequently, the drifting current initially exhibited a peak value and a saturated value at a later point. This value was proportional to the ratio of the charged particles, and it was similar to this ratio when it is higher than 1:1. The output voltage of the photodiode due to the panel reflexibility rate was proportional to the ratio of the charged particles. However, the response speed decreased if the ratio was higher than 1:1. It is expected that the results of this study will contribute to the analysis of the charging of charged particles in electrophoretic-based electronic paper, and the selection of an appropriate concentration.