• Title/Summary/Keyword: Electrical Panel

Search Result 1,127, Processing Time 0.036 seconds

Analysis on the Discharge Characteristics of AC Plasma Display Panel with Counter Sustain Electrodes (교류형 플라즈마 표시기의 신 대향형 구조에 대한 방전 특성 분석)

  • Bae, Hyun-Sook;Whang, Ki-Woong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1579-1583
    • /
    • 2008
  • We proposed the new structure of ac plasma display panel(PDP) to improve the luminous efficacy and driving voltage characteristics. Through two-dimensional numerical simulations, we analyzed the effects of new counter discharge type, which consists of counter sustain electrodes and auxiliary electrodes. Generally, an advantage of AC PDP with the counter sustain electrodes has been known for the driving characteristics of the low voltage. In this work, the new counter structure using the ignition discharge by the auxiliary pulse applied to the address electrode showed the result of the increased luminous efficacy. The short gap discharge between two auxiliary electrodes on the front plate could intensity the long gap discharge between counter electrodes. The reliability of simulation result could be confirmed by the experimental result in the test panel.

Solar Cells Characteristics Tester

  • Jirawath, Parnklang;Amnard, Jenjirodpipat;Santi, Hanklar
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.511-511
    • /
    • 2000
  • The equipment is used for testing the electrical characteristics of solar cells that were connected to be a solar panel, which can be found anywhere of solar power plant. This device was built from power switch devices f3r sinking the high current of the solar panel. The processor is a controller, which controls the quantity of the current, which flow through the switching devices and collect the characteristic of the solar panel. The tester can measure the current, voltage, temperature, and light intensity, which are main factors that affect the electrical characteristics of solar cells. 12 bits resolution signal converter is used to change the measuring levels so we can change measuring levels to 4096 levels, and these data are stored in tile memory. The equipment can also calculate the maximum power of the solar system panel.

  • PDF

A Study of Optical Properties of Assembled Plasma Display Panel with 3-D Optical Code

  • Park, Hyun-Myung;Kang, Jungwon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.1
    • /
    • pp.67-71
    • /
    • 2012
  • The optical properties of PDP, such as the transmittance and reflectance, were analyzed with 3D optical code. Three different ITO-less structures in the front panel are examined. In the assembled panel study, the test 1 structure shows 16.6% and 10.2% higher reflectance than the structures of tests 2 and 3, respectively. In order to check the validation of the simulation result, three 7.5-inch test panels having the same geometry and property are fabricated as simulation models. The calculated reflective properties are compared to the measured data from real panels. The relative difference extracted from the simulation and measurement methods is less than 4.9% and are well matched.

Study on Vacuum Packaging of Field Emission Display (Field Emission Display의 고진공 실장에 관한 연구)

  • Lee, Duck-Jung;Ju, Byeong-Kwon;Jang, Jin;Oh, Myong-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.103-106
    • /
    • 1999
  • In this paper, we suggest the FED packaging technology that have 4mm thickness, using sodalime glass-to-sodalime glass electrostatic bonding. It based on conventional silicon-glass bonding. The silicon film was deposited an around the exhausting hole on FED backside panel. And then, the silicon film of panel was successfully bonded with capping(bare) glass in vacuum environment and the FED panel was vacuum-sealed. In this method, we could achieve more 153 times increased conductance and 200 times increased vacuum efficiency than conventional tube packaging method. The vacuum level in panel, by SRG test, was maintained about low 10$_{-4}$ Torr during above two months And, the light emission was observed to 0.7-inch tubeless packaged FED. Then anode current was 34 $\mu$ A. Emission stability was constantly measured for 10 days.

  • PDF

A study on the fixed-concentrating hybrid panel using reflector (반사판을 이용한 고정식 집광형 복합 Panel에 대한 연구)

  • 김완태;김규조;김승환;허창수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.352-355
    • /
    • 2000
  • Although for its great amount and cleanness solar energy has been studied a lot as a substitute one, it is limitedly being utilized in heating water and partly in special usage for high cost of installing solar cell in Korea. Consider domestic shortage of natural energy resources and environmental issue by the Climate Agreement treated in 1994, it is urgently needed to study the practical application of solar energy as a substitute one. Therefore in order to increase the efficiency of solar cell and decrease its price, this study treats the course of designing and manufacturing the panel that connects sunlight by fixing reflector.

  • PDF

Design and Implementation of a Bidirectional Power Supply Charger Using Super Capacitors and Solar Panel for Robot Cleaner Applications (슈퍼 커패시터 및 태양전지를 이용한 로봇청소기용 양방향 충전시스템 설계)

  • Zheng, Tao;Piao, Sheng-Xu;Kwon, Dae-Hwan;Qiu, Wei-Jing;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.97-102
    • /
    • 2016
  • In this paper, a bidirectional power supply charger is proposed. This system used a solar cell panel to generate electricity and used super capacitors to store these energies, which can be used for the robot cleaner or some other electronic products. This system include a phase-shift controlled bidirectional dual active bridge (DAB) converter, solar panel super capacitors and DSP controller. In the daytime it can charge to the super capacitors to store the energy generated by the solar cell panel and in the night it will release the energy stored in the super capacitors to loads. A prototype of the proposed bidirectional power supply charger system was designed which can achieve 18V to 30V input, 10V/20W output to super capacitors and 9V/6.5W output when it acts as a charger for the robot cleaner. The system is verified to be sTable and reliable by both the simulation and experimental results.

Fabrication of Triode-Type CNT-FED by A Screen-printing of CNT Paste

  • Kwon, Sang-Jik;Shon, Byeong-Kyoo;Chung, Hak-June;Lee, Sang-Heon;Choi, Hyung-Wook;Lee, Jong-Duk;Lee, Chun-Gyoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.866-869
    • /
    • 2004
  • A carbon nanotube field emission display(CNT FED) panel with a 2 inch diagonal size was fabricated by using a screen printing of a prepared photo-sensitive CNT paste and vacuum in-line sealing technology. After a surface treatment of the patterned CNT, only the carbon nanotube tips are uniformly exposed on the surface. The diameter of the exposed CNTs are usually about 20nm. The sealing temperature of the panel was around 390 $^{\circ}C$ and the vacuum level was obtained with $1.4{\times}10^{-5}$torr at the sealing. The field emission properties of the diode type CNT FED panel were characterized Now, we are developing a triode type CNT FED with a self-aligned gate-emitter structure.

  • PDF

Development of Electric Safety Monitoring System and Cabinet Panel for Traditional Markets (재래시장 상가 분전반 및 전기안전감시시스템 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.123-128
    • /
    • 2010
  • In this paper, in order to reduce the electric disaster damage which is caused by with electric equipment of traditional markets, we developed cabinet panel and the electric safety monitoring system which is able to monitor the electrical equipments condition(over current, leakage, arc, WH, electrical fire factor etc.) at traditional markets. We constructed Test-bed for testing reliability of electric safety monitoring system and the actual condition investigation about electrical equipment of traditional market. This paper will be used with the data for an actual demonstration project after reinforcing problems which are occurred to operation of traditional market actual loads.

cactus Fence electrode structure in AC PDP to improve luminous efficacy (AC PDP의 효율 향상을 위한 cactus Fence 전극구조)

  • Jung, Sun-Gil;Nam, Hyung-Woo;Kim, Dong-Hyun;Park, Cha-Su;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1311-1312
    • /
    • 2008
  • 차세대 대형 FPD(Flat Panel Display)로 각광받는 PDP(Plasma Display Panel)는 cost, 소비전력, 효율 등의 문제점이 있다. 본 연구에서는 저가격화를 실현하기 위하여 종래 사용되었던 투명전극인 ITO(Indium-Tin Oxide)전극 대신 금속(Ag) 전극만을 사용하여 공정을 간소화한 Fence 전극구조를 제안하였다. 그리고 소비전력의 감소와 효율의 향상을 위해 격벽쪽의 전극을 제거하여 방전경로상의 저항을 증가시켜 방전전류를 감소시키는 동시에 하전입자의 격벽손실을 줄이는 4-inch Test Panel을 제작하여 전기광학적 특성 실험을 하였다. 제안한 구조의 돌기길이를 변화시켜 방전개시전압, 휘도, 소비전력, 효율 등을 측정, 비교하여 power가 14%감소하여 효율을 11% 향상 시킬 수 있었다.

  • PDF

Analysis of Current Signals for Overcurrent and Series Arc in Traditional Market Shops (재래시장 상가에서 과전류 및 직렬아크의 전류 신호에 대한 분석)

  • Kim, Doo-Hyun;Hwang, Dong-Kyu;Kim, Sung-Chul;Kim, Sang-Ryull;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.42-48
    • /
    • 2012
  • This paper is aimed to analysis of electrical fire risk by overcurrent and series arc signals in traditional market shops Firstly, the field state investigation was conducted for shops at the traditional market (30 shops). At each shop in the traditional market, load characteristics were investigated and thermal characteristics in Panel were analyzed. Thermal characteristics in Panel is an indicator that can determine the impact of overcurrent. Results of the field state investigation found out four shops which showed abnormal thermal characteristics in Panel. Electrical load characteristics of these 4 shops were simulated by experimental setup consists of generator, motor and heater. In order to verify the electrical fire risk by electrical loads of 4 shops, arc and overcurrent experiments were conducted. The waveshapes of arc and overcurrent are investigated in both the time and frequency domains to find signal characteristics. The results obtained in this paper will be very helpful for the prevention of electrical fires occurred at the shops in the traditional market.