• Title/Summary/Keyword: Electrical Inspection

Search Result 614, Processing Time 0.03 seconds

Experimental Study on the Effect of Specimen Size on Electrical Resistivity Measurement (전기비저항 측정에서 실험체 크기의 영향에 대한 실험적 연구)

  • Lim, Young-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.164-169
    • /
    • 2018
  • In this study, the effect of the size of the specimen on the apparent resistivity was investigated at the laboratory level for electrical resistivity. The specimens were measured for apparent resistivity by fabricating specimens with different sides and heights. Experimental results show that the apparent resistivity increases as the side and height of the specimen become smaller. Also, it was confirmed that the influence of the size of the specimen on the electrical resistivity measurement was not linear.

Position Control of Inspection Robot with Unknown Boom Vibration Using Fuzzy Controller (미지의 붐 진동을 위한 퍼지 제어기를 사용한 탐사 로봇의 위치 제어)

  • Lee, Seung-Chul;Han, Byung-Jo;Park, Ki-Kwang;Jang, Gi-Ho;Yang, Hai-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.464-465
    • /
    • 2008
  • This paper proposed a robust controller in order to handle the boom vibration of inspection robot. While a inspection robot moves on boom with vibration by weight occurs. Therefore, Boom as structure like cantilever beam appears vibration by weight of inspection robot. The Z axis of inspection robot operates with Sliding structure. inspection robot is used "Fuzzy Controller" for position control with Z axis. The developed robot system is composed of the specially designed car for inspection robot. The proposed Fuzzy Controllers are used to track position reference signal of Z axis. A Experiment verify that the proposed Fuzzy Controller design method can achieve favorable control performance with regard to external disturbance.

  • PDF

Development of an intelligent and integrated system for automatic inspection of steam-generator tubes in nuclear power plant (원전 증기 발생기 전열관 검사 자동화를 위한 지능형 통합 시스템 개발)

  • Kang, Soon-Ju;Choi, Yoo-Rark;Choe, Seong-Su;Woo, Hee-Gon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.3
    • /
    • pp.236-241
    • /
    • 1996
  • This paper presents a new eddy current testing system for inspecting tubes of steam generator in nuclear power plant. The proposed system adopted embedded expert system concept to automate tasks of the inspection such as inspection planning and flaw signal interpretation, and integrated all the tasks into a client/server type computing architecture using database management system. Therefore, human factor errors occurred during inspection could be minimized and the inspection data could be transferred in real-time. As a result, we can increase the level of inspection confidence and the productivity of a personal inspector. A prototype of the proposed system has been developed for 5 years and the test operation has been performed in domestic nuclear power plants.

  • PDF

Design and Analysis of Illumination Optics for Image Uniformity in Omnidirectional Vision Inspection System for Screw Threads (나사산 전면검사 비전시스템의 영상 균일도 향상을 위한 조명 광학계 설계 및 해석)

  • Lee, Chang Hun;Lim, Yeong Eun;Park, Keun;Ra, Seung Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.3
    • /
    • pp.261-268
    • /
    • 2014
  • Precision screws have a wide range of industrial applications such as electrical and automotive products. To produce screw threads with high precision, not only high precision manufacturing technology but also reliable measurement technology is required. Machine vision systems have been used in the automatic inspection of screw threads based on backlight illumination, which cannot detect defects on the thread surface. Recently, an omnidirectional inspection system for screw threads was developed to obtain $360^{\circ}$ images of screws, based on front light illumination. In this study, the illumination design for the omnidirectional inspection system was modified by adding a light shield to improve the image uniformity. Optical simulation for various shield designs was performed to analyze image uniformity of the obtained images. The simulation results were analyzed statistically using response surface method, from which optical performance of the omnidirectional inspection system could be optimized in terms of image quality and uniformity.

A Study on Measurement Technique of Insulation Resistance for Non-interrupting Inspection Using Non-contact Voltage Phase Detection Technology (비접촉 전압위상 검출 기술을 이용한 무정전 절연저항 측정 방법에 관한 연구)

  • Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Dong-Woo;Lim, Young-Bae;Choi, Dong-Hwan;Kim, Yong-Hyeok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1106-1112
    • /
    • 2018
  • In this paper, measurement techniques are presented to test the performance of insulation without interruption if it is difficult to measure insulation resistance. Especially, non-contact voltage phase detection techniques have been developed that can be applied in environments where it is difficult to find voltage measurement locations such as component receptors. The performance verification of the non-interrupting insulation resistance measuring devices has been tested against existing products using standard calibration equipment and test jigs. The validation confirmed performance within 2 % for direct contact type and within 10 % for non-contact type. In addition, the procedure to make continuous insulation test using the equipment was proposed.

Internal Defect Analysis of Transformers using DGA (유중가스분석을 통한 변압기 내부결함 분석)

  • Kim, Seong-Hwan;Park, Tae-Sik
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.354-359
    • /
    • 2020
  • DGA(Dissolved Gas Analysis) is regularly performed to detect internal defects of power transformers and prevent failures. The overheating or discharging in the transformer can be confirmed by DGA but the defective parts should be identified by internal inspection. However, winding or iron core defects cannot be checked by internal inspection, so it is impossible to establish actions by DGA alone. In this paper, the internal defect mode is analyzed and presented based on the transformer internal inspection reports, and the internal defect can be predicted by considering DGA.

Visual Inspection Method Which Improves Accuracy By using Histogram Transformation (히스토그램 변환을 사용하여 정확도를 향상시킨 외관 Vision 검사 방법)

  • Han, Kwang-Hee;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.58-63
    • /
    • 2009
  • The appearance inspection of various electronic products and parts was executed by the eyesight of human. The appearance inspection is applied to the most electronic component of LCD Panel, flexible PCB and remote control. If the appearance of electronic products of small and minute size is inspected by the eyesight of human, we can't expect the stable inspection result because inspection result is changed by condition of physical and spirit of the checker. Therefore currently machine vision systems are used to many appearance inspection fields instead of inspection by human. The many problems of inspection by the checker are not occurred in machine vision circumstance. However, the inspection by automatic machine vision system is mainly influenced by illumination of workplace. In this paper, we propose a histogram transform method for improving accuracy of machine visual inspection.

An Investigation into the Actual Condition of Electrical Equipments Installation for the Inspection Method Development Based on IEC 60364 (IEC 60364기반 건축전기설비 점검기법 개발을 위한 현장실태 조사)

  • Jung, Jin-Soo;Han, Woon-Ki;Lee, Han-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.36-41
    • /
    • 2009
  • In this paper an Investigation into the actual condition of electrical equipment installation for the inspection method development based on IEC 60364. The analysis objects are the difference between electrical equipments installation in korea & electrical equipments installation based on the IEC 60364. The measurement elements are loop impedance, operating characteristic of circuit breaker and protective conductor continuance. As a result, the korea electrical equipments installation was almost same the TT system but some different of protective conductor continuance. Electrical equipments installed TN-C-S has noting problem about installation but manager dose not understand about IEC 60364.

Development of Defect Inspection System for Polygonal Containers (다각형 용기의 결함 검사 시스템 개발)

  • Yoon, Suk-Moon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.485-492
    • /
    • 2021
  • In this paper, we propose the development of a defect inspection system for polygonal containers. Embedded board consists of main part, communication part, input/output part, etc. The main unit is a main arithmetic unit, and the operating system that drives the embedded board is ported to control input/output for external communication, sensors and control. The input/output unit converts the electrical signals of the sensors installed in the field into digital and transmits them to the main module and plays the role of controlling the external stepper motor. The communication unit performs a role of setting an image capturing camera trigger and driving setting of the control device. The input/output unit converts the electrical signals of the control switches and sensors into digital and transmits them to the main module. In the input circuit for receiving the pulse input related to the operation mode, etc., a photocoupler is designed for each input port in order to minimize the interference of external noise. In order to objectively evaluate the accuracy of the development of the proposed polygonal container defect inspection system, comparison with other machine vision inspection systems is required, but it is impossible because there is currently no machine vision inspection system for polygonal containers. Therefore, by measuring the operation timing with an oscilloscope, it was confirmed that waveforms such as Test Time, One Angle Pulse Value, One Pulse Time, Camera Trigger Pulse, and BLU brightness control were accurately output.