• 제목/요약/키워드: Electrical IT Equipment

검색결과 1,195건 처리시간 0.024초

배전계통 적정 신뢰도 유지를 위한 설비교체 순위 평가 (Component Replacement Ordering Evaluation for Proper Reliability Maintenance in Power Distribution System)

  • 이희태;김재철;문종필;추철민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.48-50
    • /
    • 2005
  • New environment change of electric power system focused in consumer's energy supply and demand. But electric power reliability preservation and reliability improvement countermeasure also need for long-term. It is need that change equipments that is composing electric power system in well-timed time and by maintaining, prevent breakdown beforehand and prevent consumer's power interruption by equipment fail. However, as only quantitative estimation is available by reliability estimation method that is presented in existing, it is no to use in dictionary fault prevention. Therefore, applied optimum reliability preservation through existent equipment fault data analysis of electric power system in equipment replace side, and this when maintain equipment replace of electric power system for reliability preservation using responsiveness analysis to base ordering evaluate. In existing about main equipment plain that this paper is power system the valued failure rate use this by score and precedence of electric power system equipment for replace of system considered expense.

  • PDF

시뮬레이션 기반의 전기 제어 패널 원격 교육 모델에 관한 연구 (A Study on the Simulation-Based Electric Control Panel Distance Learning Model)

  • 노찬숙
    • 한국융합학회논문지
    • /
    • 제11권10호
    • /
    • pp.31-36
    • /
    • 2020
  • 공학 교육의 수행 방법 중 하나인 가상 시뮬레이션 교육이 확산되고 있는 상황에서, 일반적인 온라인 교육은 이론적인 학습 위주의 수업, 간단한 소형 프로젝트의 실습만이 원격으로 이루어지고 있는 실정으로, 다양한 교육용 콘텐츠의 보급이 필요하다. 최근 스마트 팩토리의 확산으로 대부분의 생산 기업들은 자동제어를 이용하여 제품의 생산, 검수, 포장을 하고 있다. 자동화 설비의 동작은 전기를 이용하여 제어하고 있는 상황으로, 전기와 관련된 학습이 다양한 학과에서 운영되고 있으나, 전기의 특성상 안전상의 문제 및 실습 기자재의 고비용으로 온라인 학습이 어려운 상황이다. 본 논문에서는 전기 실습과 관련된 교육의 성취감을 향상시키기 위하여 시뮬레이션 기반의 전기 제어 패널 원격 교육 모델을 제안한다. 제안 모델의 실험을 통하여 학습자들은 기존 기자재의 사용에 의한 온라인 교육보다, 가상 시뮬레이션 교육의 만족도가 상승한 것을 확인하였으며, 향후 자동화 설비 교육의 기초 과정으로 활용될 수 있을 것이다.

포항가속기연구소의 전력사용량에 대한 분석 (Analysis of used electric power for pohang accelerator laboratory)

  • 손창호;손윤규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.31-32
    • /
    • 2006
  • Pohang accelerator Laboratory is from 1994 analyzed electric power amount used for about 10 years. It is one of equipment that consume electric power of greate electric power to single test equipment. Accelerator Laboratory institute investigates the consumption rate of energy that is spent to each building could divide by linear accelerator and save ring and analyzed about the equipment utilization rate and average electric power. Countermeasure that this treatise can forecast power loss of electric power by equipment through analysis of electric power amount used and heighten the utilization rate of equipment wishes to do comparative analysis.

  • PDF

DC 궤도회로의 효율적인 운용방법에 대한 연구 (A study on efficient operation of DC track circuit)

  • 장동완;전태현
    • 조명전기설비학회논문지
    • /
    • 제28권2호
    • /
    • pp.70-75
    • /
    • 2014
  • A track circuit is a critical piece of equipment that allows the existence of the trains on the track to be detected. Train detection is very important for the signal safety equipment. It allows for the confirmation of a train's location, the locking of switch points, the coordination of safe distance between trains, and the advance notice of a train's arrival. Track circuits can be powered by AC or DC. The DC track circuits are usually used on non-electrified tracks. On these tracks, many signal errors can be caused by lightning or problems with the power source. These problems can also cause damages to the rectifiers which must be repaired or replaced, promptly. This issue is especially problematic in the summer because of the higher frequency of thunderstorms. Issues with track circuits also cause problems for other equipment, such as railroad crossings and switch points. This further disrupts the safe operation of trains. This study aims to enhance maintenance efficiency and improve safety by utilizing parallel operation and multiplexing of a DC track circuit as well as installing an external surge protector. The experimental results on the operation of the proposed method is also presented.

Suppression of Glow Corona on Streamer and Influence of Thin Wire on its Inception

  • Sima, Wenxia;Fan, Shuochao;Yang, Qing;Wang, Qi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1759-1764
    • /
    • 2015
  • Glow corona is a kind of streamer-free corona that can suppress upward leaders in transmission lines. Thus, it has good application potential in lightning protection. This paper investigates its corona characteristics. The suppression characteristic of glow corona on streamer is studied in air gap under negative DC voltage by wrapping thin wires on the electrode. The effect of thin wire winding patterns on the gap breakdown voltage is analyzed. Results are considered to be attributed to the inception condition of glow corona. Thus an inception test of glow corona is also conducted, and the inception voltage is obtained. Results show that the inception voltage decreases with short winding pitch. Thus an investigation on the inception of glow corona influenced by thin wire is conducted, and an influential factor is proposed to evaluate the influence. The inception regular of thin wire glow corona presented in this paper has certain reference value for the application of glow corona in transmission lines.

부가적으로 설치된 장치 결함으로 인한 차량화재 사고사례 분석 (Analysis of Vehicle Fire Accident Caused by Defect of Optionally Established Equipment)

  • 박남규;김진표;남정우;송재용
    • 한국안전학회지
    • /
    • 제29권5호
    • /
    • pp.40-46
    • /
    • 2014
  • This paper deal with due to the additional equipment established on the vehicle fire accident cases. Recently, vehicle was recognized as other living spaces and it was increasing installation of additional devices such as a black box, multivision, additional battery and so on. However, these additional devices were established on the vehicle by non-specialists such as the general public user or manufacturing and distributors of additional devices since the vehicle factory. Resulting from the additional equipments due to installation errors in these additional equipments connected to the electrical wiring insulation damage or electrical breakdown occurs, and finally leading to a fire caused by the additional equipments. Therefore, additional equipment established on the vehicle due to a fire in order to prevent accidents during the manufacturing process of these devices are installed. If not installed unless the manufacturing process, the installation of additional equipments established by professional who knows the vehicle structure that will be able to prevent the fire.

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

항공전자장비의 구조해석 및 설계에 대한 연구 (A Study on the Structural Analysis and Design of Avionics Equipment)

  • 최인호
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.2015-2022
    • /
    • 2012
  • 본 논문은 항공전자장비의 구조해석을 통한 하우징과 인쇄회로기판의 해석과 설계에 관한 것으로 대기자료 컴퓨터 개발 사례를 통한 연구결과이다. 항공기에 장착되는 전자장비는 전기적인 특성 외에도 운용환경에 따른 구조 설계가 매우 중요하고 설계 단계에서부터 해석을 통한 입증이 되어야 한다. 본 연구에서는 장착되는 항공 장비의 응력과 진동 요구도를 분석하여 해석 결과를 통하여 설계에 적용하고 요구도에 대해서 입증하는 방법에 대한 것이다. 구조 해석은 상용 소프트웨어를 사용하였으며 하우징의 내부 리브 설계에 대한 적합성을 확인하고 인쇄회로 기판의 변위를 계산하여 전자 부품 배치에 활용하는 방법에 대해서 제시하였다.

탈이온수의 압력과 정제된 $N_2$가스가 ILD-CMP 공정에 미치는 영향 (Influence of DI Water Pressure and Purified $N_2$Gas on the Inter Level Dielectric-Chemical Mechanical Polishing Process)

  • 김상용;이우선;서용진;김창일;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.812-816
    • /
    • 2000
  • It is very important to understand the correlation of between inter dielectric(ILD) CMP process and various facility factors supplied to equipment to equipment system. In this paper, the correlation between the various facility factors supplied to CMP equipment system and ILD-CMP process was studied. To prevent the partial over-polishing(edge hot-spot) generated in the wafer edge area during polishing, we analyze various facilities supplied at supply system. With facility shortage of D.I water(DIW) pressure, we introduced an adding purified $N_2$(P$N_2$)gas in polishing head cleaning station for increasing a cleaning effect. DIW pressure and P$N_2$gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. We estimated two factors (DIW pressure and P$N_2$gas) for the improvement of CMP process. Especially, we obtained a uniform planarity in patterned wafer and prohibited more than 90% wafer edge over-polishing. In this study, we acknowledged that facility factors supplied to equipment system played an important role in ILD-CMP process.

  • PDF

지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석 (Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.