• 제목/요약/키워드: Electrical Fan Heater

검색결과 15건 처리시간 0.025초

에너지 절약형 전기 온풍기 개발 (Development of Energy Saving Electric Fan Heater)

  • 김진봉;구대현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.97-99
    • /
    • 1994
  • Energy saving electric fan heater that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil. it is simpler and cheaper than fan heater. In this study, shaded-pole motor that is low cost and simple in spite of low efficiency was used for th fan heater.

  • PDF

고효율 유도가열형 전기온풍기에 관한 연구 (A Study on the Electrical Fan Heater using High Efficiency Induction Heating)

  • 신대철;우형균
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.24-30
    • /
    • 2012
  • A proposed the electrical fan heater using induction heating is innovative system which applied IH(Induction Heating) magnetic induction heating generated from induction-heated metallic package and high-frequency power circuit technique for thermal converse technique. In this occurs not burning, so that the working environment and deterioration of products can be improved. The existing heater that low efficiency by heated resistance or using fossil fuel of coal, diesel, kerosene has problems about burden for high cost price. In this paper are compared efficiency the existing heaters and designed electrical fan heaters using 3[kW]-Class full-bridge resonant inverter. In addition, action analysis and application of system are discussed.

에너지 절감형 전기 유류 겸용 온풍기 개발 (Development of Electrical and Oil Heater for Energy Saving)

  • 정성원;김동건;공상호
    • 한국기계가공학회지
    • /
    • 제10권5호
    • /
    • pp.38-43
    • /
    • 2011
  • This study was carried out to evaluate the structural stability of hybrid type fan heater. The evaluation of structural safety of hybrid fan heater was conducted by using Ansys Workbench and CFX-11 under the design condition. The hybrid fan heater was operated by heat transfer for heat source supplied from electric heater and combustion gas. According to result of structural analysis, the maximum equivalent stress of hybrid fan heater was 150MPa when the temperature of heat transfer fluids was $150^{\circ}C$. It was found that the hybrid fan was structurally safe because the value of maximum equivalent stress was smaller than that of yield stress of the material.

친환경 에너지 절감형 전기온풍기 기구설계 (Electric Fan Heater Design for Eco-Energy Saving)

  • 설용태
    • 한국산학기술학회논문지
    • /
    • 제17권4호
    • /
    • pp.474-479
    • /
    • 2016
  • 친환경에너지에 대한 요구가 높아지면서 전기에너지의 사용은 계속 증가하고 있다. 최근 친환경, 에너지 절약을 위해서 유도가열을 이용한 여러 가지 가열방식에 대한 관심이 높아지고 있다. 본 논문에서는 전자유도현상을 이용한 유도가 열방식을 이용하여 보다 친환경적이고 에너지 절약이 가능한 전기온풍기를 설게 제작하였다. 온풍기는 송풍부, 유도가열부 및 전력변환부 등 3부분으로 구성하였다. 유도가열부는 송풍부에 결합되어 송풍부로부터 발생된 바람이 가열되어 분출되며, 전력변환부는 고주파를 인가하여 자속을 발생시킴으로써 유도가열부의 내부를 가열시킨다. 발열방식은 유도가열의 원리를 적용하고, 전력변환효율성을 높이기 위해 공진형 인버터를 사용하였다. 공진형 인버터는 풀브리지 전압형 직렬부하 공진형 인버터를 사용하였다. 유도가열부는 세라믹 계열의 절연체와 SUS40계열의 금속체를 사용했으며, 전력변환부는 정류부, 필터부 및 공진형 인버터부 등으로 구성 하였다. 본 연구에서 제안한 전기온풍기는 기존의 전기히터와 가스히터 등과 비교한 결과, 온도 상승속도가 빠르고, 사용에너지 비용이 절감되는 등 경제성도 있음을 보였다. 개발된 전기온풍기는 가정용, 상업용 및 농업용 등 여러 분야에 친환경 에너지절감형 온풍기로의 적용 가능성이 있다.

Thermo Motor 설계 및 특성연구 (The study on the Characteristics and Design of the Thermo Motor)

  • 구대현;김진봉;노규석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1035-1037
    • /
    • 1993
  • Thermo motor that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil, it is simpler and cheaper than general fan heater. In this study, shaded-pole motor was used that is low cost and simple in spite of low efficiency.

  • PDF

시뮬레이션에 의한 벼의 누적혼합 상온통풍건조의 송풍기 및 가열기의 운영방법에 관한 연구 (Fan and Heater Management Schemes for Layer Filling and Mixing Drying of Rough Rice with Natural Air by Simulation)

  • 금동혁;한충수;박춘우
    • Journal of Biosystems Engineering
    • /
    • 제23권3호
    • /
    • pp.229-244
    • /
    • 1998
  • This study was performed to determine proper fan and heater management schemes for natural air drying of rough rice in round steel bin with stirring device under Korean weather conditions. A computer simulation model was developed to predict moisture content changes, energy requirements, and drymatter losses during drying of rough rice by natural air. Drying test was conducted to validate the simulation model using round steel bin of holding capacity of 300ton at Rice Processing Complex in Jincheon. The bin was filled with rough rice every day and mixing by stirring device. Moisture contents, ambient air temperatures, relative humidities, static pressures in plenum chamber in the bin, airflow rates, and electrical and fuel energy were measured. Relative errors of moisture content changes predicted by the simulation model were below 5ft, and relative errors of final moisture content, final grain weight, required energy ranged from 0.9% to 6%. These not levels indicated that the simulation model can satisfactorily predict the performance factors of natural air drying system such as drying rates and energr consumptions comparing error level of 10% to 15% in other drying simulation models generally used in dryer desists. Twelve different fan and heater management schemes were evaluated using the computer simulation model based on three hourly weather data from Suweon for the period of 1952-1994. The best management schemes were selected comparing the drymatter losses, required drying times, required energy consumptions. Operating fan without heating only when ambient relative humidity was below 85% or 90% appeared to be the most effective method of In operation in favorable drying weather. Under adverse drying climates or to reduce required drying time, operating fan continuously, and heating air with $1.5^{\circ}C$ temperature rise only when ambient relative humidity was over 85% appeared to be the most suitable method.

  • PDF

저전력 가정용 식품건조기 개발에 관한 실험적 연구 (Experimental Study on the Development of Food Drying Machine for Home Use Using Low Electricity)

  • 김순호;김기완;김훈
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.43-49
    • /
    • 2015
  • This study has been analyzed and investigated the possibility for the substitution of a heat source with the application of PTC(Positive Temperature Coefficient Heater) in a food drying machine. And this experiment was conducted to measure temperatures at the upper part of the vessel and the heat sink. And the structure has the many holes plane connected with the external air in the upper part of similar volumetric vessel, and attached to the PTC heater (3sets) of total consumption electricity of 120[W] in Al radiant heat structure and the small fan (2sets) in the suitable space of the lower part. Consequently, it was found that at the most conditions of food drying test with the seven holes(5mm) under the control temperature $62^{\circ}C$, the optimum drying condition formatted and the optimum time range especially appeared from 6,500 second to 7,000 second in case of drying test on banana sample.

초초임계압 발전소 보일러 제어전략 설계 (The Strategy Design of Control Logic for Ultra Super-Critical Power Plant Boiler)

  • 박두용;김병철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.223-224
    • /
    • 2008
  • 초초임계압 화력발전 제어계통 설계와 관련하여 보일러 제어시스템의 기본 요건인 제어전략을 구현하기 위해 현재 표준화력 500MW 제어시스템과 제어로직을 기반으로 1000MW급에서 필요로 하는 새로운 구조의 제어에 요구되는 제어전략에 대해 각종 제어 운전 모드의 구성과 각 운전 모드에서의 제어전략을 개발하고 있다. 최신제어시스템에서 중요하게 취급되는 자동 플랜트 제어(Automatic Plant Control, APE)의 각종 제어전략 구성에 중점을 두고 있으며 Unit Master Control, Boiler Master Control, Turbine blaster Control, Throttle Pressure Control, Fuel/Air Master Control, Forced Draft Fan Control, Induced Draft Fan Control, Primary Air Fan, Feed Water Master Control, Super Heater/Reheater Steam Temp Control 등의 제어전략을 논하고, 실제 프로세스 응단특성 파악을 위해 국내 신규발전소를 방문하여 수집한 프로세스 응답시험 결과와 특성을 분석하고 USC에 적용하기위한 보일러 제어전략에 대해 논하고자 한다.

  • PDF

전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발 (Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication)

  • 김상동;박지호;김동완
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

용해로 전기배선의 설치환경에 따른 절연저항 추이 분석 (Analysis of the Insulation Resistance Trend according to the Installation Environment of the Electric Wiring of the Melting Furnace)

  • 고봉석;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권2호
    • /
    • pp.15-22
    • /
    • 2023
  • In this study, the process and the environment of a melting furnace, located in Workplace A in Chungnam Province was inspected, and the insulation resistances of electrical circuits and motors were measured, and their changes over five years (2017-2021) were analyzed. It was found that the exhaust fan, oil pumps #A and #B, and heater were installed in 2010. Their insulation resistances decreased from 2017. Specifically, the insulation resistance of Oil Pump #A decreased from 100 (㏁) in 2018 to 20(㏁) in 2021, an 80% reduction. The fast decrease in insulation resistance was due to the high temperature of the melting furnace affecting surrounding the electrical facilities. A safety management scheme on the electrical facility of the melting furnace was proposed.