• Title/Summary/Keyword: Electrical Fan Heater

Search Result 15, Processing Time 0.02 seconds

Development of Energy Saving Electric Fan Heater (에너지 절약형 전기 온풍기 개발)

  • Kim, Jin-Bong;Koo, Dae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.97-99
    • /
    • 1994
  • Energy saving electric fan heater that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil. it is simpler and cheaper than fan heater. In this study, shaded-pole motor that is low cost and simple in spite of low efficiency was used for th fan heater.

  • PDF

A Study on the Electrical Fan Heater using High Efficiency Induction Heating (고효율 유도가열형 전기온풍기에 관한 연구)

  • Shin, Dae-Chul;Woo, Hyoung-Gyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.24-30
    • /
    • 2012
  • A proposed the electrical fan heater using induction heating is innovative system which applied IH(Induction Heating) magnetic induction heating generated from induction-heated metallic package and high-frequency power circuit technique for thermal converse technique. In this occurs not burning, so that the working environment and deterioration of products can be improved. The existing heater that low efficiency by heated resistance or using fossil fuel of coal, diesel, kerosene has problems about burden for high cost price. In this paper are compared efficiency the existing heaters and designed electrical fan heaters using 3[kW]-Class full-bridge resonant inverter. In addition, action analysis and application of system are discussed.

Development of Electrical and Oil Heater for Energy Saving (에너지 절감형 전기 유류 겸용 온풍기 개발)

  • Chung, Sung-Won;Kim, Dong-Keon;Gong, Sang-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.38-43
    • /
    • 2011
  • This study was carried out to evaluate the structural stability of hybrid type fan heater. The evaluation of structural safety of hybrid fan heater was conducted by using Ansys Workbench and CFX-11 under the design condition. The hybrid fan heater was operated by heat transfer for heat source supplied from electric heater and combustion gas. According to result of structural analysis, the maximum equivalent stress of hybrid fan heater was 150MPa when the temperature of heat transfer fluids was $150^{\circ}C$. It was found that the hybrid fan was structurally safe because the value of maximum equivalent stress was smaller than that of yield stress of the material.

Electric Fan Heater Design for Eco-Energy Saving (친환경 에너지 절감형 전기온풍기 기구설계)

  • Sul, Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.474-479
    • /
    • 2016
  • As the Eco-energy is recently required, electrical energy is fast increased. Several induction heating methods are attractive for Eco-energy and energy saving. In this paper, electrical fan heater was designed and developed with new concept for energy saving by electromagnetic induction heating. Proposed system was composed of three module, blast part, induction heating part and power transformation part. Induction heating method was adapted for heating and the resonant inverter was used for increasing of the power transformation efficiency. Full-bridge resonant inverter was adopted to resonant inverter. This system was composed of induction heating part made with metal(SUS 40 series), and power transformation part made with rectifier module, filter module and resonant inverter. From these results, the proposed new electric heater could be saved the energy from faster increasing the temperature compared to commercial gas and other electric heater. This electrical fan heater is possible to be used in field of home, commercial and agricultural area for eco-energy saving heater.

The study on the Characteristics and Design of the Thermo Motor (Thermo Motor 설계 및 특성연구)

  • Koo, Dae-Hyun;Kim, Jin-Bong;No, Kyu-Seog
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1035-1037
    • /
    • 1993
  • Thermo motor that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil, it is simpler and cheaper than general fan heater. In this study, shaded-pole motor was used that is low cost and simple in spite of low efficiency.

  • PDF

Fan and Heater Management Schemes for Layer Filling and Mixing Drying of Rough Rice with Natural Air by Simulation (시뮬레이션에 의한 벼의 누적혼합 상온통풍건조의 송풍기 및 가열기의 운영방법에 관한 연구)

  • 금동혁;한충수;박춘우
    • Journal of Biosystems Engineering
    • /
    • v.23 no.3
    • /
    • pp.229-244
    • /
    • 1998
  • This study was performed to determine proper fan and heater management schemes for natural air drying of rough rice in round steel bin with stirring device under Korean weather conditions. A computer simulation model was developed to predict moisture content changes, energy requirements, and drymatter losses during drying of rough rice by natural air. Drying test was conducted to validate the simulation model using round steel bin of holding capacity of 300ton at Rice Processing Complex in Jincheon. The bin was filled with rough rice every day and mixing by stirring device. Moisture contents, ambient air temperatures, relative humidities, static pressures in plenum chamber in the bin, airflow rates, and electrical and fuel energy were measured. Relative errors of moisture content changes predicted by the simulation model were below 5ft, and relative errors of final moisture content, final grain weight, required energy ranged from 0.9% to 6%. These not levels indicated that the simulation model can satisfactorily predict the performance factors of natural air drying system such as drying rates and energr consumptions comparing error level of 10% to 15% in other drying simulation models generally used in dryer desists. Twelve different fan and heater management schemes were evaluated using the computer simulation model based on three hourly weather data from Suweon for the period of 1952-1994. The best management schemes were selected comparing the drymatter losses, required drying times, required energy consumptions. Operating fan without heating only when ambient relative humidity was below 85% or 90% appeared to be the most effective method of In operation in favorable drying weather. Under adverse drying climates or to reduce required drying time, operating fan continuously, and heating air with $1.5^{\circ}C$ temperature rise only when ambient relative humidity was over 85% appeared to be the most suitable method.

  • PDF

Experimental Study on the Development of Food Drying Machine for Home Use Using Low Electricity (저전력 가정용 식품건조기 개발에 관한 실험적 연구)

  • Kim, Soon-Ho;Kim, Ki-Wan;Kim, Hoon
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.43-49
    • /
    • 2015
  • This study has been analyzed and investigated the possibility for the substitution of a heat source with the application of PTC(Positive Temperature Coefficient Heater) in a food drying machine. And this experiment was conducted to measure temperatures at the upper part of the vessel and the heat sink. And the structure has the many holes plane connected with the external air in the upper part of similar volumetric vessel, and attached to the PTC heater (3sets) of total consumption electricity of 120[W] in Al radiant heat structure and the small fan (2sets) in the suitable space of the lower part. Consequently, it was found that at the most conditions of food drying test with the seven holes(5mm) under the control temperature $62^{\circ}C$, the optimum drying condition formatted and the optimum time range especially appeared from 6,500 second to 7,000 second in case of drying test on banana sample.

The Strategy Design of Control Logic for Ultra Super-Critical Power Plant Boiler (초초임계압 발전소 보일러 제어전략 설계)

  • Park, Doo-Yong;Kim, Byung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.223-224
    • /
    • 2008
  • 초초임계압 화력발전 제어계통 설계와 관련하여 보일러 제어시스템의 기본 요건인 제어전략을 구현하기 위해 현재 표준화력 500MW 제어시스템과 제어로직을 기반으로 1000MW급에서 필요로 하는 새로운 구조의 제어에 요구되는 제어전략에 대해 각종 제어 운전 모드의 구성과 각 운전 모드에서의 제어전략을 개발하고 있다. 최신제어시스템에서 중요하게 취급되는 자동 플랜트 제어(Automatic Plant Control, APE)의 각종 제어전략 구성에 중점을 두고 있으며 Unit Master Control, Boiler Master Control, Turbine blaster Control, Throttle Pressure Control, Fuel/Air Master Control, Forced Draft Fan Control, Induced Draft Fan Control, Primary Air Fan, Feed Water Master Control, Super Heater/Reheater Steam Temp Control 등의 제어전략을 논하고, 실제 프로세스 응단특성 파악을 위해 국내 신규발전소를 방문하여 수집한 프로세스 응답시험 결과와 특성을 분석하고 USC에 적용하기위한 보일러 제어전략에 대해 논하고자 한다.

  • PDF

Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication (전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발)

  • Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

Analysis of the Insulation Resistance Trend according to the Installation Environment of the Electric Wiring of the Melting Furnace (용해로 전기배선의 설치환경에 따른 절연저항 추이 분석)

  • Suk Bong Ko;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.15-22
    • /
    • 2023
  • In this study, the process and the environment of a melting furnace, located in Workplace A in Chungnam Province was inspected, and the insulation resistances of electrical circuits and motors were measured, and their changes over five years (2017-2021) were analyzed. It was found that the exhaust fan, oil pumps #A and #B, and heater were installed in 2010. Their insulation resistances decreased from 2017. Specifically, the insulation resistance of Oil Pump #A decreased from 100 (㏁) in 2018 to 20(㏁) in 2021, an 80% reduction. The fast decrease in insulation resistance was due to the high temperature of the melting furnace affecting surrounding the electrical facilities. A safety management scheme on the electrical facility of the melting furnace was proposed.