Nuclear Material Containment/Surveillance System for Nuclear Facility (핵물질 취급 시설의 격납/감시 시스템)

  • Song, D.Y.;Lee, S.Y.;Kim, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.490-492
    • /
    • 2005
  • Unattended continuous containment/surveillance systems for safeguards of nuclear facility result in large amounts of image and radiation data, which require much time and effort to inspect. Therefore, it is necessary to develop system that automatically pinpoints and diagnoses the anomalies from data. In this regards, this paper presents the nuclear material containment/surveillance system that integrates visual image and radiation data.

  • PDF

A Study on A Gas Circuit Breaker Development Using Simplified Synthetic Testing Facility (간이합성시험설비를 이용한 가스차단기 개발에 관한 연구)

  • Chong, Jin-Kyo;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.902-904
    • /
    • 2007
  • A $SF_6$ gas circuit breakers are widely used for short circuit current interruption in EHV or UHV power system. During a $SF_6$ gas circuit breaker development, Simplified synthetic testing facility is used. This paper shows how simplified synthetic testing facility is used for a SF6 gas circuit breaker development.

  • PDF

A Study on Constructing the Prediction System Using Data Mining Techniques to Find Medium-Voltage Customers Causing Distribution Line Faults (특별고압 수전설비 관리에 데이터 마이닝 기법을 적용한 파급고장 발생가능고객 예측시스템 구현 연구)

  • Bae, Sung-Hwan;Kim, Ja-Hee;Lim, Han-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2453-2461
    • /
    • 2009
  • Faults caused by medium-voltage customers have been increased and enlarged their portion in total distribution faults even though we have done many efforts. In the previous paper, we suggested the fault prediction model and fault prevention method for these distribution line faults. However we can't directly apply this prediction model in the field. Because we don't have an useful program to predict those customers causing distribution line faults. This paper presents the construction method of data warehouse in ERP system and the program to find customers who cause distribution line faults in medium-voltage customer's electric facility management applying data mining techniques. We expect that this data warehouse and prediction program can effectively reduce faults resulted from medium-voltage customer facility.

Development of Web-based Light Facility Control Management System (Web기반 조명시설 제어 관리 시스템의 개발)

  • Chang, Byong-Kun;Jeon, Chang-Dae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.182-189
    • /
    • 2005
  • In this paper, A web-based server system was developed based on PDA(Personal Digital Assistants) for controlling and managing light facilities on-line with wireless communication efficiently. The control box of current light facilities may be implemented based on simple operational function. The operational quality of the light facilities will be efficiently improved with some practical advantages such as reduction of required facility, manpower and time in managing the lights and control boxes by using the popular PDA.

A Study on the Establishment of Cable-TV Facility in the Apartment Complex (공동주택 유선방송설비 설치에 관한 연구)

  • 홍규창;이기홍
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.110-114
    • /
    • 1995
  • Subscriber-Unit(SU) method in apartment-housing is used as the plan for the Cable-TV(CATV) receiving facility. But it is decided to apply Notification NO.1994-18 of the Ministry of Communications regulations starting in march, 10.1994. In this study, a new plan of CATV-receiving facility according to the Notification NO.1994-18 is suggested, and it is designed to apply lone-wire from an amplifier box to a SU or another amplifier box. Proposed results adopt the Head End(HE) to introduc Integrated Service Digital Network(ISDN) and to raise added-value of apartment-housing.

  • PDF

Detection Characteristics of a Novel Coupler for GIS PD Detection

  • Park, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa;Kim, Ik-Soo;Kim, Jae-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.224-229
    • /
    • 2003
  • An ultra high frequency (UHF) coupler possessing ultra wide band (UWB) characteristics ranging from hundreds of MHz to several GHz is desirable for the detection of the partial discharge (PD) pulses because the pulses propagate with rise time shorter than one nanosecond in a gas-insulated substation (GIS). Thus, the authors have proposed a log-periodic antenna for GIS PD detection. Various parameters of the coupler such as frequency bandwidth, coupler gain, radiation pattern, and coupler geometry were considered throughout the simulations. The experiments for the detection characteristics of the coupler were carried out in the mock-up GIS chamber. The results indicated that the detection characteristics of the coupler are dependent on the installation angle of the coupler, the position of the coupler in the hand hole and the existence of the spacer.

Development of Data-Flow Control Algorithm of Wireless Network for Sewage Disposal Facility

  • Jung, Soonho;Shin, Jaekwon;Kang, Jeongjin;Lee, Seungyoun;Lee, Junghoon
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.14-19
    • /
    • 2015
  • Recently, water sewage disposal facilities are able to manage real-time data collection and record management through compact broadband modem LAN switching technology. Therefore, it needs more stable and efficient facility management. So, we required practical use of environmental facilities convergence based on broadband integrated modem. In this paper, we proposed short distance wireless communication network of compact broadband modem for sewage disposal facilities. And it received data inside of water treatment facility using the two communication methods (IEEE802.11x and IEEE802.15.4x). Then, our proposed an data-flow control algorithm of wireless network technology will prioritize processing data when emergency happen through collecting data, analysis data and processing. Lastly, we proved usefulness by experiment and simulation analysis.

UsN based Soundness Monitoring Diagnosis System of Power Transmission Steel Tower (UsN 기반의 송전철탑 건전성 감시진단시스템 기본설계)

  • Lee, Dong-Cheol;Bae, Ul-Lok;Kim, Woo-Jung;Min, Bung-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.56-62
    • /
    • 2007
  • In this paper, design method for power tower hazard diagnosis/predition system based on UsN was proposed. The proposed method used multi-hybrid sensors to measure rotation, displacement, and inclination state of power tower, and made decision/prediction of hazard of power tower. System design was made with requirement analysis of monitoring for transmission power facility and use of MEMS and optic fiber sensors. For hazard decision, analysis of correlation was made using sensor output. LN based on IEC61850,international standard for digital substation, was also proposed. For transmission facility monitoring, digital substation and power tower were considered as parts of power facility networks.

DC Arc Characteristics Analysis according to U1699B Test Standardof the Status (태양광발전설비 DC 아크특성 분석)

  • Wan-Su Kim;Kwang-Muk Park
    • Current Photovoltaic Research
    • /
    • v.11 no.4
    • /
    • pp.118-123
    • /
    • 2023
  • The main cause of solar facility fires is arc, and in the last 3 years ('16 to '18), about 80% of domestic solar facility fires have been caused by arcs. The capacity of solar power facilities installed around the world continues to increase, and fires caused by arcs are also expected to increase as the solar power generation facilities that were initially installed become obsolete, In this paper, an arc generation test was conducted based on the UL1699B test standard. As a result of the test, the arc generation satisfied the minimum arc current according to the test conditions, and DC arc characteristics were analyzed through data such as arc voltage and arc current according to variables such as speed of moving electrodes and electrode spacing.

A Study of Broadcasting Facility Remote Management System at Station (도시철도 역사방송설비 원격제어시스템에 관한 고찰)

  • Choi, Yoon-Seog
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2069-2075
    • /
    • 2010
  • The broadcasting system for the customer safety and conveniency is one of the important convenience facilities taking charge of customer guidance, emergency situation broadcasts for the people waiting at the platform, waiting lounge and train approaching broadcasts. To maintain this broadcasting facility local management control system(LMC) is needed. LMC observes operation status of the facility components which is set up at station and the observation results are confirmed through out remote management PC installed in the jurisdiction branch office. The staff only observes and confirms the errors of the electrical power source at broadcasting facility components accordingly the real mechanical troubles are detected by on-the-spot survey. this paper deals with existing broadcasting system only acting as a simple observation function and the research of LMC function extension which controls, monitors and tests broadcasting facility.

  • PDF