• Title/Summary/Keyword: Electrical Facility' Subject

Search Result 9, Processing Time 0.045 seconds

Effects of LT Cooperative Learning on Academic Achievement of 'Electrical Facility' Subject in Industrial High School (공업고 전기과 '전력설비' 과목에서 LT협동학습이 학업성취도에 미치는 효과)

  • Kim, Jin-Soo;Shin, Choong-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.3
    • /
    • pp.152-157
    • /
    • 2004
  • The purpose of the study was to identify the effects of LT cooperative learning and traditional competitive learning on academic achievement by the level of learning ability in industrial high school students. The results of the study were as follows; the score of posttest of the experimental low grade group was significantly higher than that of control low grade group (p<.05), and the score of posttest was significantly higher than that of pretest in the experimental low and middle grade group (p<.05). Based on these results, it was concluded that LT cooperative learning had positive effect on the enhancement of industrial high school student's academic achievement than the traditional lecture learning. Its effect on high grade students was negative, but its effect was significantly positive on both middle grade and low grade level students.

A study based on question on consciousness of electrical safety in electrical facilities for private use (자가용 전기설비 수용가의 전기안전의식에 대한 설문조사)

  • Kim, Sun-Gu;Bae, Seck-Myung;Haung, Gaung-Su;Yi, Geon-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.394-397
    • /
    • 2005
  • In korea, the power consumption is increasing every year because of economic growth, requiring of convenience and delightfulness condition. As increasing power consumption, Private Use is steadily increasing and the rate of electrical accident is increasing. Therefore we research the electrical safety culture of our people by the survey of electrical safety. The subject to investigation is possessor, occupier of Private Use and electrical safety manager. This paper will be used to base data for the protection of electrical accident and facility accident at Private Use

  • PDF

On the Improvement of Facility to Performance Evaluation and Security of Safety through the Application of AHP Method in Railroad Signal Control System (철도 신호제어 시스템의 AHP 기법 적용을 통한 성능평가 대상설비 항목 개선 및 안전성 확보에 관한 연구)

  • Hwang, Sunwoo;Kim, Joouk;Kim, Youngmin;Kim, Hyungchul;Lee, Soohwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.1
    • /
    • pp.71-79
    • /
    • 2021
  • The railroad facilities are intended for long-term operation as the initial acquisition costs necessary for infrastructure construction are high. Therefore, regular maintenance of railroad facilities is essential, and furthermore, system reliability through systematic performance evaluation is required. In this study, the signal control system of railroad electrical equipment was selected as the subject of research and the performance evaluation target facility selection study was conducted using AHP. The results of the study can contribute to the reliability of the signal control system as well as to the reliability of the railroad system, which is a higher system.

An Optimal Configuration and Feasibility Study for Community Energy System (CES) (합리적인 지역 에너지 시스템(Community Energy System)의 구성과 경제성 검토)

  • Kee W. B.;Park Y. U.;Kim K. H.;Jang S. I.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.123-125
    • /
    • 2004
  • This paper describes an optimal configuration of Community Energy System (CES) for the multi-energy consumers and analyzes economical feasibility for such system. The most of previous feasibility studies for Co-Generation plants of CES in Korea have shown negative results due to the abnormally low price of power rate in Korea. However, in order to overcome this situation a new approach was examined in this Paper. The efforts of this approach the selection of the low price but reliable facility and maximizing the capacity factor of the facility. MGT was selected in view of low price and good reliability. In order to maximize the capacity factor the system capacity should be quite lower than the actual required Electrical and Heat load of the subject entity. In this report 100 kW Co-Generation facility was selected in view of conservative analysis. The results of the analysis showed that pay back period may vary from 4 to 5 yens according to the application of LNG rates whether it is to-generation rate or the normal business rate. With the analysis in this paper we confirmed that CES is feasible even in Korea if we do not insist to select the capacity of CES to cover all the energy required but select a smaller size of CES compared to the actual requirement, which can allow full load operation of the system continuously.

  • PDF

Development of Ambulatory Speech Audiometric System (휴대용 어음청력검사 시스템 구현)

  • Shin, Seung-Won;Kim, Kyeong-Seop;Lee, Sang-Min;Im, Won-Jin;Lee, Jeong-Whan;Kim, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.645-654
    • /
    • 2009
  • In this study, we present an efficient ambulatory speech audiometric system to detect one's hearing problems at an earlier stage as possible without his or her visit to the audiometric testing facility such in a hospital or a clinic. To estimate a person's hearing threshold level in terms of speech sound response in his or her local environment, a digital assistant(PDA) device is used to generate the speech sound with implementing audiometric Graphic User Interface(GUI) system. Furthermore, a supra-aural earphone is used to measure a subject's hearing threshold level in terms of speech sound by the compensating the transducer's gain by adopting speech sound calibration system.

Innovation of Engineering Education in Department of Engineering Education at Virginia Tech in the United States (미국 Virginia Tech 공학교육과에서의 공학교육 혁신)

  • Kim, Jin-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.504-505
    • /
    • 2007
  • In 2004, a department of engineering education was established at Virginia Tech and Purdue university in the United States. Innovation of engineering education for improving the quality of engineering college education has been progressing. Content of subject of engineering exploration was developed newly for engineering college freshmen. And, effect of a sustainable energy design project on academic achievement for engineering freshmen at Virginia Tech in 2006 was researched. The project was performed throughout a 6 weeks period with one by 50 minutes lecture by professor and one 90 minutes workshop by TAs (Teaching Assistants) every week. To analyze the data, statistical package SPSS (ver. 15.0) was used. In responses to an open-ended question about freshmen students' perceptions of their improvement in design skills, the 3 most identified skills were teamwork, design process, knowledge. In, Korea, an innovation relating to engineering curriculum, facility, instructional strategy and so on will be required.

  • PDF

A Fundamental Study on Applying BIM to Power Manage System of Super Tall Buildings (초고층 건축물 전력관리 시스템에 BIM 적용을 위한 기초적 연구)

  • Jo, Chan-Won;Kwon, Soon-Ho;Lee, Woon-Jae;Roh, Tae-Im;Ock, Jong-Ho
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.2
    • /
    • pp.140-148
    • /
    • 2012
  • This study aims to provide power monitoring system for super tall buildings with 3D BIM (Building Information Modeling) technology. In order to realize this subject, standard specifications for BIM objects and attributes were studied through analyzing processes and elements of electrical utilities for power management systems applied for super tall buildings. These standard BIM specifications could be used by designers, contractors and facility operators, and thus could be helpful to realize BIM information sharing between multiple disciplines and construction phases. And further study has been suggested to develop standard specification and applications from this study.

An Experimental Study on the Development of Electromagnetic Shielding Concrete Wall for Shielding High-altitude Electromagnetic Pulse (HEMP) (고고도 전자기파(HEMP)차폐를 위한 전자파 차폐 콘크리트 벽체 개발에 관한 실험적 연구)

  • Choi, Hyun-Jun;Kim, Hyung-Chul;Lim, Sang-Woo;Lee, Han-Seung
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.2
    • /
    • pp.169-177
    • /
    • 2017
  • Rather than causing damage from heat, blast, and radiation of a regular nuclear weapon, recently, it is predicted that North Korea has been inventing high altitude electromagnetic pulse (HEMP) missile in order to incapacitate electronic equipment. HEMP shielding facility is used for military purpose today. Despite the electromagnetic shielding effects from high quality compression plates, problems may include such as the possibility of electromagnetic influx resulting in the welding of the compression plates, and difficulties and high cost of construction. Therefore, in this study, a high electrical conducting material was added to the concrete experimental subject to ensure the shielding effect through electromagnetic waves to for the concrete structure, instead of building a shielding facility separately for the structure. Also, among the experimental subjects, 100 ${\mu}m$ of Iron-Aluminum alloy metal spraying coat was applied to two types with the highest shielding effect, and to two types with the lowest shielding effect. The result of the experiment indicates that experimental subjects added with a high electrical conductivity material did not meet the minimum shielding criteria of MIL-STD-118-125-1 standard, but all the experimental material applied to the metal spraying coating satisfied the minimum shielding criteria. In conclusion, it is considered that 100 µm of Iron-Aluminum alloy metal spraying coat contains high efficiency in the HEMP shielding.

A Study on Design of Optimal Location for Renewable Energy Facility Using GIS (GIS를 사용한 재생에너지설비 최적 위치 설계에 관한 연구)

  • Jung, Moon-Seon;Moon, Chae-Joo;Chang, Young-Hak;Kim, Young-Gon;Lee, Sook-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.2
    • /
    • pp.357-368
    • /
    • 2018
  • For well over 100 years, oil has enabled remote communities to generate electricity and enjoy the benefits of a consistent electrical supply. Relying solely on oil for electricity generation has left island and remote communities exposed to several risks and drawbacks. Oil-based electricity generation is often more expensive and subject to price volatility, which can result in the use of risky fuel hedging strategies. The residents of islands and remote communities express concern over the future impacts of climate change or insist on their opinions for the corresponding action with reduction of carbon emissions. These risks and drawbacks can be overcomed with continuing cost reductions in solar, wind, and energy storage technologies by maker. Reducing costs is not always a straightforward process, relying on more diversely and renewably arranged renewable energy sources led to reduced local construction cost in every situation reviewed in this study. In this paper, a convenient and simple design solution which will facilitate the optimum location and transmission route of renewable energy facility using GIS(Geographic Information System) is proposed. The suggested solutions exercised to the case of geomoon island using GIS and identified by local site survey.