• 제목/요약/키워드: Electrical Detection

검색결과 4,019건 처리시간 0.036초

A Biologically Inspired New Hardware Fault Detection: immunotronic and Genetic Algorithm-Based Approach

  • Lee, Sanghyung;Kim, Euntai;Park, Mignon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제4권1호
    • /
    • pp.7-11
    • /
    • 2004
  • This paper proposes a new immunotronic approach for the fault detection in hardware. The suggested method is, inspired by biology and its implementation is based on genetic algorithm. Tolerance conditions in the immunotronic system for fault detection correspond to the antibodies in the biological immune system. A novel algorithm of generating tolerance conditions is suggested based on the principle of the antibody diversity and GA optimization is employed to select mature tolerance conditions in immunotronic fault detection system. The suggested method is applied to the fault detection for MCNC benchmark FSMs (finite state machines) and its effectiveness is demonstrated by the computer simulation.

50kW 태양광 설비의 아크 검출 알고리즘 개발 (Development of Arc Detection Algorithm for 50 kW Photovoltaic System)

  • 김상규;이창성;지평식
    • 전기학회논문지P
    • /
    • 제67권1호
    • /
    • pp.27-32
    • /
    • 2018
  • In this paper, we developed an algorithm to detect arc of PV power plant through frequency analysis. For arc detection based on frequency analysis, the filter should be designed to emphasize the difference between the arc state and the normal state. Therefore, in this paper, we analyzed the arc detection performance according to various filter structures. The arc detection algorithm developed in this paper extracts the filtering signal on current by using various filters and then calculates the frequency components and total energy using the FFT. In the final step, the arc is detected using the calculated energy magnitude. In order to verify the performance of the proposed arc detection algorithm, experiments were conducted on 51 kW solar inverters connected to power line. Through various experiments, it was confirmed that the proposed method effectively detects the arc.

SSTDR에서 시간-주파수 상관을 활용한 저압 케이블의 고장 검출 (Fault Detection of Low Voltage Cable using Time-Frequency Correlation in SSTDR)

  • 전정채;김택희;유재근
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.498-504
    • /
    • 2015
  • This paper proposed an Spread Spectrum Time Domain Reflectometry (SSTDR) using time-frequency correlation analysis in order to have more accurate fault determination and location detection than classical SSTDR despite increased signal attenuation due to the long distance to cable fault location. The proposed method was validated through comparison with classical SSTDR methods in open- and short-circuit fault detection experiments of low-voltage power cables. The experimental results showed that the proposed method can detect correlation coefficients at fault locations accurately despite reflected signal attenuation so that cable faults can be detected more accurately and clearly in comparison to existing methods.

HOG를 이용한 파트 기반 손 검출 알고리즘 (Part-based Hand Detection Using HOG)

  • 백정현;김지수;윤창용;김동연;김은태
    • 한국지능시스템학회논문지
    • /
    • 제23권6호
    • /
    • pp.551-557
    • /
    • 2013
  • 지능형 로봇 연구 분야에 있어, 손을 이용한 제스처 인식은 매우 중요한 연구 분야로 간주 되고 있으며, 스마트 폰, 스마트 TV 등에 상용화 되어왔다. 제스처 인식에 있어, 강인한 손 검출 기술을 필수적인데, 손의 모양이 일정치 않고, 복잡한 배경이나 조명변화 아래서는 손 검출이 쉽지 않다는 어려움이 있다. 본 논문은 실내 환경에서 사용자가 가리키는 방향을 인식하기 위한 손 검출 알고리즘을 제안한다. 손 검출에 대한 오검출을 최대한 줄이기 위해, 머리-어깨 검출 결과를 기반으로 손 검색 영역을 한정시키고, 피부색을 이용해 최소한의 후보군들을 발생시켜, HOG-SVM을 이용하여 손을 검출하였다. 그리고 머리-어깨, 손 검출 결과를 통해 팔의 방향 각도를 추정하였다. 제안된 방법은 실제 실내 환경에서 추출된 영상을 통해 실험을 진행하였고, 강인한 성능을 확인하였다.

전기화재 예지원리 및 징후검출 시스템 구조 (Prediction Principle and System Structure for the Detection of Incipient Electrical Fire)

  • 김창종
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권4호
    • /
    • pp.71-77
    • /
    • 1995
  • Electrical fire in residential, commercial, and industrial areas occupies 40 percent of overall fire accidents as of the year of 1994. The causes of most electrical fires were studied and, based on this investigation, the principle of the early detection or prediction of the electrical fires is developed. The basic principle is to early detect electrical arcs or sparks caused by faulty connections and insulation failures. the structure of the prediction system based on microcontroller technique is presented.

  • PDF

Analysis of Joint Multiband Sensing-Time M-QAM Signal Detection in Cognitive Radios

  • Tariq, Sana;Ghafoor, Abdul;Farooq, Salma Zainab
    • ETRI Journal
    • /
    • 제34권6호
    • /
    • pp.892-899
    • /
    • 2012
  • We analyze a wideband spectrum in a cognitive radio (CR) network by employing the optimal adaptive multiband sensing-time joint detection framework. This framework detects a wideband M-ary quadrature amplitude modulation (M-QAM) primary signal over multiple nonoverlapping narrowband Gaussian channels, using the energy detection technique so as to maximize the throughput in CR networks while limiting interference with the primary network. The signal detection problem is formulated as an optimization problem to maximize the aggregate achievable secondary throughput capacity by jointly optimizing the sensing duration and individual detection thresholds under the overall interference imposed on the primary network. It is shown that the detection problems can be solved as convex optimization problems if certain practical constraints are applied. Simulation results show that the framework under consideration achieves much better performance for M-QAM than for binary phase-shift keying or any real modulation scheme.

Throughput Analysis and Optimization of Distributed Collision Detection Protocols in Dense Wireless Local Area Networks

  • Choi, Hyun-Ho;Lee, Howon;Kim, Sanghoon;Lee, In-Ho
    • Journal of Communications and Networks
    • /
    • 제18권3호
    • /
    • pp.502-512
    • /
    • 2016
  • The wireless carrier sense multiple access with collision detection (WCSMA/CD) and carrier sense multiple access with collision resolution (CSMA/CR) protocols are considered representative distributed collision detection protocols for fully connected dense wireless local area networks. These protocols identify collisions through additional short-sensing within a collision detection (CD) period after the start of data transmission. In this study, we analyze their throughput numerically and show that the throughput has a trade-off that accords with the length of the CD period. Consequently, we obtain the optimal length of the CD period that maximizes the throughput as a closed-form solution. Analysis and simulation results show that the throughput of distributed collision detection protocols is considerably improved when the optimal CD period is allocated according to the number of stations and the length of the transmitted packet.

실제적인 Time-Selective Fading Channels에서의 Orthogonal Space-Time Block Codes의 Detection Scheme (A robust detection scheme of OSTBCs with channel estimation errors over time-selective fading channels)

  • 유동헌;이재홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.17-18
    • /
    • 2006
  • In this paper, we propose a robust detection scheme of OSTBCs with channel estimation errors over time-selective fading channels. Channel estimation errors are inevitable over time-selective fading channels and even small channel estimation errors dramatically degrade the performance of space-time block coding schemes. Therefore, it is desired to investigate the effect of channel estimation errors on the performance of the proposed detection scheme compared with the existing detection scheme. The proposed detection scheme minimizes noise enhancement and impact of channel estimation errors which occur in an existing detection scheme. It is shown by simulations that the proposed detection scheme performs better than the existing detection scheme over time-selective fading channels.

  • PDF

개선된 텍스쳐 정보를 이용한 갑작스러운 조명 변화에 강인한 이동 물체 탐지 (Moving Object Detection Robust to Sudden illumination Change using Modified Texture Information)

  • 오요한;장형진;김수완;최진영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.268-269
    • /
    • 2008
  • Moving object detection is a fundamental technique in visual surveillance. Robust technique to enhance performance of moving object detection is required for several bad conditions in real external circumtance. In case of sudden illumination change in outdoor condition, many objects are determined as moving object though they are not really moving, but just their illumination changes. This makes the detection result untrustworthy. In this paper, robust moving object detection to sudden illumination change using gaussian mixture background model and new texture information using background from the weighted sum of recent images is proposed.

  • PDF

Bagged Auto-Associative Kernel Regression-Based Fault Detection and Identification Approach for Steam Boilers in Thermal Power Plants

  • Yu, Jungwon;Jang, Jaeyel;Yoo, Jaeyeong;Park, June Ho;Kim, Sungshin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1406-1416
    • /
    • 2017
  • In complex and large-scale industries, properly designed fault detection and identification (FDI) systems considerably improve safety, reliability and availability of target processes. In thermal power plants (TPPs), generating units operate under very dangerous conditions; system failures can cause severe loss of life and property. In this paper, we propose a bagged auto-associative kernel regression (AAKR)-based FDI approach for steam boilers in TPPs. AAKR estimates new query vectors by online local modeling, and is suitable for TPPs operating under various load levels. By combining the bagging method, more stable and reliable estimations can be achieved, since the effects of random fluctuations decrease because of ensemble averaging. To validate performance, the proposed method and comparison methods (i.e., a clustering-based method and principal component analysis) are applied to failure data due to water wall tube leakage gathered from a 250 MW coal-fired TPP. Experimental results show that the proposed method fulfills reasonable false alarm rates and, at the same time, achieves better fault detection performance than the comparison methods. After performing fault detection, contribution analysis is carried out to identify fault variables; this helps operators to confirm the types of faults and efficiently take preventive actions.