• Title/Summary/Keyword: Electrical Data Analysis

Search Result 2,730, Processing Time 0.036 seconds

Analysis of Electrical Loads in the Urban Railway Station by Big Data Analysis (빅데이터분석을 통한 도시철도 역사부하 패턴 분석)

  • Park, Jong-young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.460-466
    • /
    • 2018
  • For the efficient energy consumption in an urban railway station, it is necessary to know the patterns of electrical loads for each usage in detail. The electrical loads in an urban railway station have different characteristics from other normal electrical load, such as the peak load timing during a day. The lighting, HVAC, communication, and commercial loads make up large amount of electrical load for equipment in an urban railway station, and each of them has the unique specificity. These loads for each usage were estimated without measuring device by the polynomial regression method with big data such as total amount of electrical load and weather data. In the simulation with real data, the optimal polynomial regression model was third order polynomial regression model with 9 or 10 independent variables.

A Study of Analysis of Fault Data in AC Electrical Railway Power System Based on COMTRADE Using PSCAD/EMTDC (PSCAD/EMTDC를 활용한 COMTRADE 기반의 교류철도 급전계통 사고 데이터 분석에 관한 연구)

  • Lee, Ji-Hye;Min, Myung-Hwan;An, Tae-Pung;Lee, Byeong-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1542-1548
    • /
    • 2018
  • When any faults occurred in electrical railway system, operators need to analysis it quickly and accurately. Existing COMTRADE based analysis tools are not enough to analysis faults occurred in electrical railway system. In this paper, it presents some functions to fault analysis for electrical railway system based on fault data formatted COMTRADE. These functions are implemented in PSCAD/EMTDC and it can be shown that analyzed results against actual electrical fault cases which were occurred in the electrical railway power system.

Analysis on Major Factors for Analysis & Application of Big Data in Electrical Commercial System (전자상거래 시스템에서 빅 데이터의 분석 및 결과 활용에 미치는 영향요소 분석)

  • Yang, Hoo-Youl;Na, Cheol-Hun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.373-375
    • /
    • 2016
  • Analyze the Big Data become a hot issue because of Smart environment, the amount of data in the world has been exploding. Result of application makes a good use of Analysis and applicate of the big data, is play an important part in application area (finance, circulation, manufacturing, disaster etc.) This paper presents an influence element for data analysis and its practical use based in result of maturity in Business process of Big Data in Electrical Commercial system.

  • PDF

Protection Assessment using Reduced Power System Fault Data

  • Littler, T.B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.172-177
    • /
    • 2007
  • Wavelet transforms provide basis functions for time-frequency analysis and have properties that are particularly useful for the compression of analogue point on wave transient and disturbance power system signals. This paper evaluates the compression properties of the discrete wavelet transform using actual power system data. The results presented in the paper indicate that reduction ratios up to 10:1 with acceptable distortion are achievable. The paper discusses the application of the reduction method for expedient fault analysis and protection assessment.

A Profile Analysis about Thermal Life Data of Electrical insulating materials at Accelerated Life Test

  • Bark, Shim-Kyu
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.12
    • /
    • pp.1814-1819
    • /
    • 2010
  • Since 1987, when statistical analyzing guide for thermal life test of Accelerated Life Test(ALT) was proposed as ANSI/IEEE Std 101, this guide has been used widely for many experiment data. Shim(2004) had done Monte Carlo simulation to compare life of two different systems or materials, based on statistic values obtained from ANSI/IEEE Std 101 data. In this study, a profile analysis is proposed for comparing life of two different systems or materials, and some examples using pre-existing data are given.

Development of a User-Friendly Application for Voltage Sag Analysis

  • Park Chang-Hyun;Jang Gil-Soo;Kim Chul-Hwan;Kim Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.145-152
    • /
    • 2006
  • This paper presents a windows application for voltage sag analysis and effective data visualization. The developed Voltage Sag Analysis Tool (VSAT) was designed by using the Object-Oriented Programming (OOP) concept and C++ programming language. The VSAT provides basic functions for voltage sag analysis such as power flow analysis, short circuit analysis and stochastic analysis. In particular, the VSAT provides effective data visualization through computer graphics and animation. Analysis results are expressed realistically and intuitively on geographical display. The Graphic User Interface (GUI) of VSAT was designed specifically for voltage sag analysis. In this paper, the development and implementation of VSAT is presented. In order to demonstrate the capabilities of VSAT, it is used to analyze the Jeju Island power system in South Korea.

Some Considerations on the Problems of PSA(Pulse Sequence Analysis) as a Partial Discharge Analysis Method (부분방전 해석 방법으로 PSA(Pulse Sequence Analysis)의 문제점에 대한 고찰)

  • Kim, Jeong-Tae;Lee, Ho-Keun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.327-330
    • /
    • 2004
  • Because of its effectiveness for the PD(partial discharge) pattern recognition, PSA(Pulse Sequence Analysis) has been considered as a new analytic method instead of conventional PRPDA(Phase Resolved Partial Discharge Analysis). However, PSA has a big problem that can misanalyze patterns in case of data missing resulting from poor sensitivity because it analyses the correlation between sequential pulses, which leads to hesitate to apply it to on-site. Therefore, in this paper, the problems of PSA such as data missing and noise adding cases were investigated. For the purpose, PD data obtained from various defects including noise adding data were used and analysed, The result showed that both cases can cause fatal errors in recognizing PD patterns. In case of the data missing, the error depends on the kinds of defect and the degree of degradation. Also, it could be noticed that the error due to adding noises was larger than that due to some data missing.

  • PDF

A Study on Temperature Analysis for Smart Electrical Power Devices (스마트 전력 기기의 온도 분석에 관한 연구)

  • Vasanth, Ragu;Lee, Myeongbae;Kim, Younghyun;Park, Myunghye;Lee, Seungbae;Park, Jwangwoo;Cho, Yongyun;Shin, Changsun
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.8
    • /
    • pp.353-358
    • /
    • 2017
  • An electrical power utility, like an electrical power pole, includes various kinds of sensors for smart services. Temperature data is considered one of the important factors that can influence the smart operations of this utility. This study suggests a method for temperature data analysis for deciding the status of the smart electrical power utilities by using Kalman Filter and Ensemble Model. The suggested approach separates the temperature data according to the different positions of the temperature sensors of a utility, then uses Kalman Filter and Ensemble Model to analyse the characteristics of the temperature variation. With detailed processes, method explains the variation between an external temperature factor like weather temperature data and the sensed temperature data, and then, analysis the temperature data from each position of electrical power utilities. In this process, the suggested method uses Kalman Filter to remove error data and the ensemble model to find out mean value of every hour of electrical data. The result and discussion of temperature analysis were described clearly with the analysed results of electrical data. Finally, we were able to check the working condition of the power devices and the range of the temperature data foe each devices, which may help to indicate any causalities with respect to the devices in the utility pole.

Development of Data Aquisition System for Electrical Power Analysis of Electrical Load equipments (전기부하설비의 전력분석을 위한 데이터 획득 시스템의 개발)

  • 이상익;전정채;유대근
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.60-66
    • /
    • 2004
  • In order to analyze voltage, current electrical power, harmonic and so on of electrical load equipments, electrical power analysis by real measurement rather than mathematical modeling is necessary, and plan of countermeasure for efficient management, energy frugality and accident prevention of electrical equipments using it is possible Especially, electrical power analysis by real measurement is indispensable in order to consider countermove of harmonic occurred by nonlinear load So, in this paper, we developed DSP(Digital Signal Processor) based low price date aquisition system, and verified it's ability by performing measurement and analysis of electrical power and harmonic in the real power system.

Statistical Analysis of Electrical Tree Inception Voltage, Breakdown Voltage and Tree Breakdown Time Data of Unsaturated Polyester Resin

  • Ahmad, Mohd Hafizi;Bashir, Nouruddeen;Ahmad, Hussein;Piah, Mohamed Afendi Mohamed;Abdul-Malek, Zulkurnain;Yusof, Fadhilah
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.840-849
    • /
    • 2013
  • This paper presents a statistical approach to analyze electrical tree inception voltage, electrical tree breakdown voltage and tree breakdown time of unsaturated polyester resin subjected to AC voltage. The aim of this work was to show that Weibull and lognormal distribution may not be the most suitable distributions for analysis of electrical treeing data. In this paper, an investigation of statistical distributions of electrical tree inception voltage, electrical tree breakdown voltage and breakdown time data was performed on 108 leaf-like specimen samples. Revelations from the test results showed that Johnson SB distribution is the best fit for electrical tree inception voltage and tree breakdown time data while electrical tree breakdown voltage data is best suited with Wakeby distribution. The fitting step was performed by means of Anderson-Darling (AD) Goodness-of-fit test (GOF). Based on the fitting results of tree inception voltage, tree breakdown time and tree breakdown voltage data, Johnson SB and Wakeby exhibit the lowest error value respectively compared to Weibull and lognormal.