• 제목/요약/키워드: Electrical Conductivity (EC)

검색결과 385건 처리시간 0.026초

팔당호 수질의 연직분포에 대한 밀도류 영향 평가 (Evaluating Effect of Density Flow from Upstream on Vertical Distribution of Water Quality at the Paldang Reservoir)

  • 공동수
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.557-566
    • /
    • 2019
  • Paldang is a river reservoir in the Midwest of Korea, which is a drinking water source for the metropolitan area. Since the Paldang Reservoir is shallow, and has a short hydraulic residence time, its water quality is directly impacted by two incoming rivers, the north Han River (NHR) and the south Han River (SHR). The NHR has different seasonal patterns of water temperature from the SHR because the NHR is greatly impacted by the discharge water from upstream dams. The electrical conductivity (EC) and other material concentrations of the SHR are usually higher than those of the NHR because its basin is limestone-based. The difference in water temperature in the two rivers causes density flow, and the distribution of the EC within the reservoir can be an indicator for monitoring density flow. From the vertical gradient of the EC at the dam site, from spring to fall, it was confirmed that the SHR flowed into the upper layer, and the NHR flowed into the lower layer, and vice versa at other times. The relative difference (RD) of the EC between the upper layer and the lower layer at the dam site was used as an indicator for density flow. The RD of the EC showed a very significant correlation with the RD of total organic carbon (r = 0.70, p < 0.001) and the RD of total nitrogen (r = 0.58, p < 0.01). This relationship is based on the assumption that the difference in electrical conductivity and water quality between the SHR and the NHR is constant. However, in many cases this assumption is inconsistent. Thus, further study is needed on more suitable indicators to evaluate the impact of density flow on water quality.

샘플러에 따른 측정 위치별 원소탄소의 농도 비율 (Ratio of Elemental Carbon Concentrations for Respective Measurement Locations according to the Sampler)

  • 차원석;김은영;최성원;최수연
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.461-472
    • /
    • 2021
  • Objectives: This study was conducted to determine the differences in EC concentrations according to the type of sampler by measuring and analyzing EC. Methods: Elemental carbon was measured in diesel engine vehicles and at the roadside. Using NIOSH method 5040, a cassette was coupled to 37 mm and 27 mm quartz filters and measurements were performed 21 times. There were 14 types of measurement methods, and polystyrene, polypropylene, and metal samplers were evenly placed inside the movable chamber. Results: The results measured using the 37 mm conductive cassette (closed/open) and the IOM sampler made of conductive materials showed a higher ratio than the other results. When the 37 mm conductive cassette was measured with the lid open, it showed a statistically significantly higher ratio than with other measurement methods (p<0.05). Conclusions: Checking the EC concentration a total of 21 times at each ratio based on the concentration of the 3-stage polystyrene cassette, it was statistically significantly higher when the 37 mm conductive cassette was open. This same cassette also showed a slightly higher EC concentration when closed. It was ascertained that some DEE was collected on the cassette wall surface due to the electrical conductivity of the polystyrene cassette, resulting in sample loss. Since EC is composed of fine particles, it is thought that electrical conductivity may affect its concentration.

절화장미 재배토양에서 희석된 토양 침출용액으로부터 포화반죽 전기전도도 추정 (Estimating Saturation-paste Electrical Conductivities of Rose-cultivated Soils from their Diluted Soil Extracts)

  • 이인복;노희명;임재현;임명순
    • 한국토양비료학회지
    • /
    • 제33권6호
    • /
    • pp.398-404
    • /
    • 2000
  • 본 시험은 높은 비율의 물로 회석된 토양용액의 EC(electrical conductivity)와 saturation parte EC($EC_e$) 간의 상관관계를 검토하고자 실시하였다. 시험토양은 24개 절화장미 재배지에서 수집하였고, 토성은 대부분 양토와 미사질양토 이었으며, 얻어진 시험 결과는 다음과 같다. 토양용액의 총이온 함량과 EC 간에는 고도의 정의 상관관계가 인정되고, 물추출 비율이 증가할수록 토양용액중 이온의 총략은 증가하였으나, 1:1, 1:2, 1:5 비율로 EC를 측정한 다음 각각 1, 2, 5를 곱한 EC 값은 $EC_e$에 비해 현저히 낮은 결과를 보였다. 이는 보다 높은 비율의 물로 추출한 용액의 EC와 $EC_e$간에 큰 오차가 있음을 의미한다. 포화 이상의 물추출조건 하에서 발생하는 이러한 오차를 감소시키기 위하여 회석된 용액의 EC값에 새로온 Diluted factor(DF)와 비선형 등식을 적용하여 $EC_e$를 추정한 결과, 두 방법 모두 측정된 ECe와 추정된$EC_e$간 1차 식의 기울기가 1에 근접하여 새로 적용된 방식들이 기존의 측정방식에 비해 정확성을 높여줄 수 있는 것으로 나타났다. 반면에 DF값은 토성에 크게 의존적이며, 비선형 등식을 이용한 측정방식은 토양의 saturation percentage에 따라 추정된 $EC_e$가 변동되므로 폭넓은 토성에 대한 추가적인 연구가 필요할 것으로 판단된다.

  • PDF

Comparison of soil nutrients, pH and electrical conductivity among fish ponds of different ages in Noakhali, Bangladesh

  • Tapader, Md. Morshed Alam;Hasan, Mehedi Mahmudul;Sarker, Bhakta Supratim;Rana, Md. Enayet Ullah;Bhowmik, Shuva
    • 농업과학연구
    • /
    • 제44권1호
    • /
    • pp.16-22
    • /
    • 2017
  • An experiment was conducted to detect aquaculture pond bottom soil nutrients, pH and electrical conductivity with a view to optimize production and to incorporate the scientific method of fish nursing, rearing and culturing at Noakhali district in Bangladesh. The soil samples were collected from the recently dug ponds (1 - 5 years) and older ponds (> 5 years). Samples were taken from five different spots in a Z shape from each pond and were mixed to get a composite sample. The composite samples from the ponds were collected in polyethylene bags and shipped to the laboratory for analysis. The soil samples were analyzed with respect to pH, electrical conductivity (EC), organic carbon (OC), organic matter (OM), nitrogen (N), phosphorous (P), potassium (K) and sulfur (S). The average value of pH, OC, OM, N, P, K and S were $7.43{\pm}0.40$, $2.21{\pm}1.43%$, $1.47{\pm}0.53%$, $2.52{\pm}0.94{\mu}g\;g^{-1}$, $0.126{\pm}0.047{\mu}g\;g^{-1}$, $3.84{\pm}1.77{\mu}g\;g^{-1}$, $0.191{\pm}0.106{\mu}g\;g^{-1}$ and $306.72{\pm}222.05{\mu}g\;g^{-1}$ respectively, in Noakhali. The average EC, OC, OM, N and P contents were found to be higher in Subornachar than those in Sonapur. On the other hand pH, K and S were found to be higher in Sonapur than the values of Subornachar. The pH, EC, OC, OM, N and S contents were found to be higher in new ponds than old ponds whereas P and K contents were found to be higher in old pond than in new pond.

황산화미생물을 이용한 새로운 수(水)중 생태독성탐지 방법 (A New Methodology of Measuring Water Toxicity using Sulfur Oxidizing Bacteria)

  • 오상은
    • 대한환경공학회지
    • /
    • 제32권6호
    • /
    • pp.555-562
    • /
    • 2010
  • 수중의 독성을 탐지하기 위하여 황산화미생물을 이용한 새로운 형태의 생태독성탐지 방법이 연구되었다. 황산화미생물이 산소 존재 하에서 황입자를 산화하여 황산을 만들게 되고 이는 EC의 증가 및 pH의 감소를 가져온다. 독성물질이 들어오면 미생물의 저해로 황산을 적게 만들게 되므로 EC의 증가 정도가 감소하게 된다. 인공하천수(EC= 0.12 mS/cm and pH=7.2)를 이용하여 황산화미생물을 배양하고 반응조를 HRT 30분으로 연속 운전한 결과 유출 인공하천수의 EC=0.5~1.2 mS/cm, pH= ~2.5이었으며 7일 동안 일정하게 유지되었다. 이러한 유입수와 유출수의 EC의 차이는 인공하천수가 독성이 없는 조건에서 일정 속도로 황산을 만들었기 때문이다. 아질산성질소 2 mg/L를 함유한 인공하천수를 넣은 결과 인공하천수 주입 후 1.5시간 경과 후 EC 값이 급격하게 감소하고 pH 값은 상승하여 독성을 쉽게 탐지 가능하였다. 최적의 체류시간은 30분이었으며 이는 황입자의 크기를 줄임으로써 더 짧은 체류시간에서 운전이 가능할 것으로 판단된다.

Dietary Modification for Reducing Electrical Conductivity of Piggery Wastewater

  • Yu, I.T.;Su, J.J.;Wu, J.F.;Lee, S.L.;Ju, C.C.;Yen, H.T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권9호
    • /
    • pp.1343-1347
    • /
    • 2005
  • A total of 108 pigs (including 36 starters, 36 growers, and 36 finishers) were randomly allocated to six treatments, which involved a 2 (Crude Protein (CP): 100 and 80% of control diet)${\times}$3 (Ca, P, Salt (CPS): 100, 80 and 60% of control diet) factorial design to evaluate the effectiveness of reducing CP and CPS in reducing wastewater EC in different stages. Another 72 starters were adopted to examine the effect of the six treatment diets (as mentioned above) on the growth performance of pigs. Activated carbon and Reverse Osmosis System (RO) were adopted to examine the reducing efficiency of wastewater EC, and ion analysis was also applied to compare with the wastewater EC in different stages of the metabolism trial. The results of wastewater EC of the six treatment diets in different stages of metabolism trial demonstrated that diminishing dietary CP or CPS decreased wastewater EC. The largest decrease of EC was approximately 30%, and was achieved with 20 and 40% reduced dietary CP and CPS, respectively. Pig growth performance deteriorated somewhat when dietary CP or CPS was diminished. Wastewater ion concentration was not always consistent with dietary CP or CPS content, except for $NO_2^{-}$, $NH_4^{+}$ and $K^{+}$, which were positively correlated with dietary CP or CPS in different stages. Activated carbon is not effective for reducing wastewater EC, while, RO system is effective (90% elimination rate) in reducing wastewater EC, but the EC of concentrated (excreted) water is around 10% higher than that of intact wastewater, representing an additional problem besides the high cost of RO system treatment.

Relationship between Seed Vigour and Electrolyte Leakage in Rice Seeds with Different Grain-filling Period

  • Kim, Jin-Ho;Lee, Sheong-Chun;Song, Dong-Seog
    • 한국작물학회지
    • /
    • 제43권3호
    • /
    • pp.147-151
    • /
    • 1998
  • The conductivity test is a measure of electrolytes leakage from plant tissue. The shorter the maturation period after heading was the greater electrical conductivity (EC) of rice seed. The polymer-coated seed was not different in EC compared with non-coated seed. As soaking time of rice seed increased, EC increased gradually. The EC varied from 9.9 to 20.7$\mu$S $cm^{-1}g^{-l}$ for control plots and from 21.3 to 41.7$\mu$S $cm^{-1}g^{-l}$ for heat-killed seeds which were produced by autoclaving seeds at 121$^{\circ}C$ for 20 minutes. The germination speed (the rate of 5th day) of rice seed was 94% at control plot, 83% at low temperature and 20% at high temperature. Besides, germination percentage was 95% for the control, 92% for the low temperature treatment and 39% for the high temperature treatment. The EC was negatively correlated (r=-0.771$^{**}$) with germination percentage at low temperature. Water uptake in seeds of 30, 40, 50 days after heading (DAH) was greater than that of 20 DAH. Plant height of seedlings was 9.84 cm for the control but 4.32 cm for the high temperature treatment, and the tallest for polymer-coated seed. Dry weight of seedlings was 0.841 g for the control and 0.287 g at high temperature. Besides, the polymer-coated seed was heavier than non-coated seed. The number of roots was largest from 40 to 50 DAH and polymer-coated seed, but was decreased from 20 to 30 DAH. The length of roots was 20.52 cm at control plot and 19.89 cm polymer-coated seed but 8.68 cm for the low temperature treatment and 7.28 cm for the high temperature treatment.

  • PDF

Effect of nitrogen types and the electrical conductivity of a nutrient solution on gray mold caused Botrytis cinerea on strawberry plants

  • Nam, Myeong hyeon;Lee, Hee chul;Kim, Tae il
    • 농업과학연구
    • /
    • 제46권1호
    • /
    • pp.103-111
    • /
    • 2019
  • Gray mold caused by Botrytis cinerea on strawberry plants is an economically significant disease in Korea. The rates for diseased fruits are high during the strawberry harvesting period from December to February, especially in hydroponic cultivation. This study assessed the effect of the nitrogen type in the soil culture and the electrical conductivity (EC) of the nutrient solution in a hydroponic culture on the gray mold incidence in 'Seolhyang' strawberry plants. The nitrogen sources assayed included calcium nitrate tetrahydrate (CN4), calcium nitrate decahydrate (CN10), ammonium sulfate (AS), and commercial fertilizer 213 (213). The effect of the EC was tested at 0.5, 0.8, 1.0, and $1.5dS{\cdot}m^{-1}$. The occurrence of gray mold varied according to the nitrogen type. The disease incidence and nitrogen content for the main nitrogen type were higher compared to the non-treated control. The AS treatment showed the highest occurrence of tipburn and gray mold. The incidence of gray mold as well as the nitrogen and phosphorus content of the leaves increased as the EC level was increased. These results indicate that the incidence of gray mold in strawberry plants is related to the nitrogen content of the leaf and the EC of the nutrient solution.

Improvement of Mechanical and Electrical Properties of Poly(ethylene glycol) and Cyanoresin Based Polymer Electrolytes

  • Oh Kyung-Wha;Choi Ji-Hyoung;Kim Seong-Hun
    • Fibers and Polymers
    • /
    • 제7권2호
    • /
    • pp.89-94
    • /
    • 2006
  • Ionic conductivity and mechanical properties of a mixed polymer matrix consisting of poly(ethylene glycol) (PEG) and cyanoresin type M (CRM) with various lithium salts and plasticizer were examined. The CRM used was a copolymer of cyanoethyl pullulan and cyanoethyl poly(vinyl alcohol) with a molar ratio of 1:1, mixed plasticizer was ethylene carbonate (EC) and propylene carbonate (PC) at a volume ratio of 1:1. The conductive behavior of polymer electrolytes in the temperature range of $298{\sim}338\;K$ was investigated. The $PEG/LiClO_4$ complexes exhibited the highest ionic conductivity of ${\sim}10^{-5}S/cm$ at $25^{\circ}C$ with the salt concentration of 1.5 M. In addition, the plasticized $PEG/LiClO_4$ complexes exhibited improvement of ionic conductivity. However, their complexes showed decreased mechanical properties. The improvement of ionic conductivity and mechanical properties could be obtained from the polymer electrolytes by using CRM. The highest ionic conductivity of PEG/CRM/$LiClO_4$/(EC-PC) was $5.33{\time}10^{-4}S/cm$ at $25^{\circ}C$.

시설재배지 토양에서 유기자재 투입이 염류활성도에 미치는 영향 (Effect of Organic Residue Incorporation on Salt Activity in Greenhouse Soil)

  • 이슬비;이창훈;홍창오;김상윤;이용복;김필주
    • 한국환경농학회지
    • /
    • 제28권4호
    • /
    • pp.397-402
    • /
    • 2009
  • In Korea, salt stress is one of the major problems limiting crop production and eco-environmental quality in greenhouse soil. The objective of this study was to evaluate the effectiveness of organic residues (Chinese milk vetch, maize stalk, rice straw, and rye straw) for reducing salt activity in greenhouse soil. Organic residues was incorporated with salt-accumulated soil (EC, 3.0 dS $m^{-1}$) at the rate of 5% (wt $wt^{-1}$) and the changes of electrical conductivity (EC) was determined weekly for 8 weeks under incubation condition at $30^{\circ}C$. The EC, microbial biomass carbon (MBC), and water soluble ions in soil was strongly affected by C/N ratio of organic residues. After 8 weeks incubation, the concentration of water soluble $NO_3{^-},\;Ca^{2+}$, and $Mg^{2+}$ was significantly decreased in organic residues having high C/N ratio (maize stalk, rice straw, and rye straw) incorporated soil compared to organic residues having lower C/N ratio (Chinese milk vetch) incorporated soil. The EC value in Chinese milk vetch incorporated soil was higher than control treatment. In contrast, maize stalk, rice straw, and rye straw amended soil was highly decreased the EC value compared to control and Chinese milk vetch applied soil after 4 weeks incubation. Our results indicated that incorporation of organic residues having high C/N ratio (>30) could reduce salt activity resulting from reducing concentration of water soluble ions.