A Study of Contact Resistance Test Considered with Measurement Uncertainty for Electric Bus Couplers with Battery-Swapping System (측정불확도를 고려한 배터리 교환형 전기버스용 접속기 접촉저항 평가에 관한 연구)

  • Kim, Kwang-Min;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.60-64
    • /
    • 2015
  • Many people think that Electric Vehicles(EVs) is the best method to resolve the problems of running out of fossil fuels. But EVs take long time for charging. So, EVs with battery swapping systems(EVBS) are developed to resolve this problem. Nonetheless, EVBS is not spreaded widely because the method of durability test in couplers is not defined. In this study, the evaluation method of durability test in couplers is defined by some standards and the measurement uncertainty is used to increase the reliability of EV couplers.

Two-Stage Inductive Power Transfer Charger for Electric Vehicles (전기자동차 충전기용 2-Stage 자기유도 무선전력전송 시스템)

  • Kim, Min-Jung;Joo, Dong-Myoung;Ann, Sang-Joon;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.134-139
    • /
    • 2017
  • In this study, an inductive power transfer (IPT) charger for electric vehicles is proposed to improve the entire system efficiency and power density by eliminating the DC-DC converter in the secondary side. In the proposed IPT charger, the DC-link voltage is adjusted according to the coupling coefficient through cascade buck-boost converter in the front-end side, and the bridgeless rectifier performs the charging of battery. The control algorithm for the proposed IPT system is theoretically explained, and the validity of the proposed system is verified by informative simulation.

A Study on the Efficiency of DC-DC Converter to Charge and Discharge Lithium Battery (리튬전지 충방전용 직류-직류 변환기의 효율에 관한 연구)

  • Kim, Hee-Sun;Koo, Do-Youn;Lee, Seung-Yong;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.205-206
    • /
    • 2010
  • This paper presents a study on the efficiency of DC-DC converter to charge/discharge lithium battery. The losses of switching device, magnetic components, output capacitor, diode, and snubber circuit are analyzed by considering the charge/discharge characteristics of the converter. Based on the loss analyses, efficiency simulation in charging/discharging process are performed.

  • PDF

Discharging Characteristics of Green cell Using MgO-Coated $Zn_2SiO_4:Mn^{2+}$ Phosphor in Plasma Display Panel

  • Han, Bo-Yong;Jeoung, Byung-Woo;Hong, Gun-Young;Yoo, Jae-Soo;Ha, Chang-Hun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.575-578
    • /
    • 2004
  • The charging tendency of $Zn_2SiO_4:Mn^{2+}$ phosphor surface was modified in order to improve discharging characteristic of green cell in an ac-plasma display panel (ac-PDP). The Zinc-silicate ($Zn_2SiO_4:Mn^{2+}$) green-emitting phosphor was coated with magnesium oxide(MgO), which is viable to have positive charge on the surface. After fabricating the green cell with MgO-coated $Zn_2SiO_4:Mn^{2+}$, the electrical and optical properties in the cell were examined. It was found that the dynamic voltage margin could be increased while the address time was reduced. It may be ascribed to the change of charging tendency of $Zn_2SiO_4:Mn^{2+}$ phosphor by MgO coating, which makes it possible to stable wall-charge accumulation. When $Zn_2SiO_4:Mn^{2+}$ phosphor was coated with 1.3wt%-MgO, the address time was reduced 1.2 ${\mu}s$ and the address voltage lowered 25 V without any misfiring problem, compared to those of typical $Zn_2SiO_4:Mn^{2+}$ phosphor layer. The luminescence intensity of green cell using MgO-coated phosphor layer was also improved by 10%.

  • PDF

Design and Evaluation of a High Concentration, High Penetration Unipolar Corona Ionizer for Electrostatic Discharge and Aerosol Charging

  • Intra, Panich;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1175-1181
    • /
    • 2013
  • The aim of this paper is to design and evaluate a high concentration, high penetration unipolar corona ionizer. The electrostatic characteristics in terms of voltage-current relationships of the present ionizer in the discharge zones for positive and negative coronas were discussed. Using ion current measurement, the concentration and penetration of ions were evaluated at corona voltages across the needle electrodes between 1 and 4 kV, flow rates between 1 and 5 L/min, and an operating pressure of 1 atm. In the discharge zone of the ionizer, the highest ion concentrations were found to be about $1.71{\times}10^{14}$ and $5.09{\times}10^{14}\;ions/m^3$ for positive and negative coronas, respectively. At the outlet of the ionizer, it was found that the highest ion concentration was about $1.95{\times}10^{13}$ and $1.91{\times}10^{13}\;ions/m^3$ for positive and negative coronas, respectively. The highest ion penetration for positive and negative coronas through the ionizer was found to be about 98 % and 33 %, respectively. The $N_it$ product for positive and negative coronas was also found to $1.28{\times}10^{13}$ and $7.43{\times}10^{13}\;ions/m^3s$, respectively. From the findings, this ionizer proved to be particularly useful as an aerosol charger for positive and negative charge before the detector in an electrical aerosol detector.

A Study on the Optimal Resource Configuration Considering Load Characteristics of Electric Vehicles in Micro Grid Environment (전기자동차 부하 특성을 고려한 마이크로그리드의 최적 전원 구성에 관한 연구)

  • Hwang, Sung-Wook;Chae, Woo-Kyu;Lee, Hak-Ju;Yun, Sang-Yun;Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.228-231
    • /
    • 2015
  • In power system research fields, one of current key issues is the construction and commercialization of micro grid site which is called green island, carbon zero island, energy independent island, building micro grid, etc. and various affiliated technologies have been being vigorously developed to realize. In addition, various researches about electric vehicles (EVs) are in progress and it is expected to penetrate rapidly with the next a few years. Some new load models should be developed integrating with electric vehicle loads because the EVs' deployment could cause the change of load composition rate on power system planning and operations. EVs are also resources for micro grid as well as distributed generation and demand response so that various supply and demand side resources should be considered for micro grid researches. In this paper, the load composition rate of residential sectors is prospected considering the deployment of EVs and the resource configuration of micro grid is optimized based on net present cost. In the optimization, the load patten of case studies includes EV's charging characteristics and various cases are simulated comparing micro grid environment and normal condition. HOMER is used to compare various cases and economic effects.

Design and Implementation of Enhanced Resonant Converter for EV Fast Charger

  • Ahn, Suk-Ho;Gong, Ji-Woong;Jang, Sung-Roc;Ryoo, Hong-Je;Kim, Duk-Heon
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.143-153
    • /
    • 2014
  • This paper presents a novel application of LCC resonant converter for 60kW EV fast charger and describes development of the high efficiency 60kW EV fast charger. The proposed converter has the advantage of improving the system efficiency especially at the rated load condition because it can reduce the conduction loss by improving the resonance current shape as well as the switching loss by increasing lossless snubber capacitance. Additionally, the simple gate driver circuit suitable for proposed topology is designed. Distinctive features of the proposed converter were analyzed depending on the operation modes and detail design procedure of the 10kW EV fast charger converter module using proposed converter topology were described. The proposed converter and the gate driver were identified through PSpice simulation. The 60kW EV fast charger which generates output voltage ranges from 50V to 500V and maximum 150A of output currents using six parallel operated 10kW converter modules were designed and implemented. Using 60kW fast charger, the charging experiments for three types of high-capacity batteries were performed which have a different charging voltage and current. From the simulation and experimental results, it is verified that the proposed converter topology can be effectively used as main converter topology for EV fast charger.

A Preliminary Research on Optical In-Situ Monitoring of RF Plasma Induced Ion Current Using Optical Plasma Monitoring System (OPMS)

  • Kim, Hye-Jeong;Lee, Jun-Yong;Chun, Sang-Hyun;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.523-523
    • /
    • 2012
  • As the wafer geometric requirements continuously complicated and minutes in tens of nanometers, the expectation of real-time add-on sensors for in-situ plasma process monitoring is rapidly increasing. Various industry applications, utilizing plasma impedance monitor (PIM) and optical emission spectroscopy (OES), on etch end point detection, etch chemistry investigation, health monitoring, fault detection and classification, and advanced process control are good examples. However, process monitoring in semiconductor manufacturing industry requires non-invasiveness. The hypothesis behind the optical monitoring of plasma induced ion current is for the monitoring of plasma induced charging damage in non-invasive optical way. In plasma dielectric via etching, the bombardment of reactive ions on exposed conductor patterns may induce electrical current. Induced electrical charge can further flow down to device level, and accumulated charges in the consecutive plasma processes during back-end metallization can create plasma induced charging damage to shift the threshold voltage of device. As a preliminary research for the hypothesis, we performed two phases experiment to measure the plasma induced current in etch environmental condition. We fabricated electrical test circuits to convert induced current to flickering frequency of LED output, and the flickering frequency was measured by high speed optical plasma monitoring system (OPMS) in 10 kHz. Current-frequency calibration was done in offline by applying stepwise current increase while LED flickering was measured. Once the performance of the test circuits was evaluated, a metal pad for collecting ion bombardment during plasma etch condition was placed inside etch chamber, and the LED output frequency was measured in real-time. It was successful to acquire high speed optical emission data acquisition in 10 kHz. Offline measurement with the test circuitry was satisfactory, and we are continuously investigating the potential of real-time in-situ plasma induce current measurement via OPMS.

  • PDF

A Monitoring Unit for Lead Storage Batteries in Stand Alone PV Generation Systems (독립형 태양광 발전소의 연 축전지 모니터링장치 개발)

  • Moon, Chae-Joo;Kim, Tae-Gon;Chang, Young-Hag;Kjm, Eui-Sun;Lim, Jung-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.1-7
    • /
    • 2009
  • Use of the PV(photovoltaic) generation system is increased in such areas as remote mountain places or islands at which electrical energy is not serviced. The stand alone PV system is required the power storage products such as battery, fly wheel and super capacitor. Several lead storage batteries are connected in series to get high voltages. The life of lead storage battery is shortened when over charge or over discharge takes place. So, it is needed to control batteries not to be overcharged or be discharged deeply. Voltage of each battery was ignored in former control methods in which overall voltage was used to control charge or discharge battery. In this study, the charging and discharging voltage variations of sealed lead storage batteries with l2V/l.2A were investigated step by step experiments. The results of the test show that one should consider and specify the state of each battery to prevent overcharge or deep discharge. With the basis of the experiments, we designed a monitoring unit to monitor battery voltages simultaneously using micro-controller. The unit measures voltage of 20 batteries simultaneously and displays data on the color LCD monitor with curved line graph. It also sends data to PC using the RS232C communication port. The designed unit was adapted to stand alone PV system with 1kW capacity and lead storage batteries are connected to the PV generation system. The number of lead storage batteries was 10 in series and 12V/250Ah each. Resistive load with 3kW was used for discharging.

A Study on Quadcopter Consisting of Dual Li-Po Battery Charging by Solar Cell in the Engineering Education Completed a Senier Project Work at the University (공학교육 이수체계에서 대학 졸업 작품용 이중 Li-Po 전원 사용 태양전지 충전 쿼드콥터 구성에 관한 연구)

  • Yoon, Seong-Geun;Kim, Kyung-Bin;Chang, Eun-Young
    • Journal of Practical Engineering Education
    • /
    • v.8 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • Depending on the college graduation project and graduation thesis regulations for the certification and graduation requirements, the quadcopter acting as a Li-Po battery that charges by solar energy are proposed a design method and improvements in theory. Quadcopter posture is balanced and confirmed by the position sensor, through a PID (Proportional Integral Differential) control. Battery switching circuit is composed of two Li-Po battery. Driving the quadcopter as one battery, and does not use other battery is charged by solar energy. A battery switching circuit is fabricated in a manner that uses two types of relays. Even if completely not charged to the battery is being driven a certain switch by the battery charging voltage from time to time, it proposes a method for increasing the endurance time and range.