• Title/Summary/Keyword: Electrical Cabinet

Search Result 60, Processing Time 0.029 seconds

A study on the Fire Hazard for the Tracking of RCD through Ground Path at Low Voltage Cabinet Panel (저압분전반에서 접지 경로를 통한 차단기의 트래킹 화재위험성에 관한 연구)

  • Kim, Dong-Ook;Lee, Ki-Yoen;Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.349-352
    • /
    • 2008
  • The electrical accidents result from insulation blackdown due to over voltage and overheating due to the excess of allowable current, deterioration of insulation performance due to the passage of time, and so on. In this paper, the insulating characteristics of phenolic resin using insulating materials for low voltage were analyzed and the tracking test was performed according to IEC Publ. 112.

  • PDF

Seismic Response Prediction Method of Cabinet Structures in a Nuclear Power Plant Using Vibration Tests (진동시험을 이용한 원자력발전소 캐비닛 구조의 지진응답예측기법)

  • Koo, Ki-Young;Cui, Jintao;Cho, Sung-Gook;Kim, Doo-Kie
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.5
    • /
    • pp.57-63
    • /
    • 2008
  • This paper presents a seismic response prediction method using vibration tests of cabinet-type electrical equipment installed in a nuclear power plant. The proposed method consists of three steps: 1) identification of earthquake-equivalent forces based on lumped-mass system idealization, 2) identification of a state-space-equation model relating input-output measurements obtained from the vibration tests, 3) seismic prediction using the identified earthquake-equivalent forces and the identified state-space-equation. The proposed method is advantageous compared to other methods based on FEM (finite element method) model update, since the proposed method is not influenced by FEM modeling errors. Through a series of numerical verifications on a frame model and 3-dimensional shell model, it was found that the proposed method could be used to accurately predict the seismic responses, even under considerable measurement noise conditions. Experimental validation is needed for further study.

A User Interface Style Guide for the Cabinet Operator Module (캐비닛운전원모듈을 위한 사용자인터페이스 스타일가이드)

  • Lee, Hyun-Chul;Lee, Dong-Young;Lee, Jung-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.203-205
    • /
    • 2005
  • A reactor protection system (RPS) plays the roles of generating the reactor trip signal and the engineered safety features (ESF) actuation signal when the monitored plant processes reach predefined limits. A Korean project group is developing a new digitalized RPS and the Cabinet Operator Module (COM) of the RPS which is used for the RPS integrity testing and monitoring by an equipment operator. A flat panel display (FPD) with a touch screen capability is provided as a main user interface for the RPS operation. To support the RPS COM user interface design, actually the FPD screen design, we developed a user interface style guide because the system designer could not properly deal with the many general human factors design guidelines. To develop the user interface style guide, various design guideline gatherings, a walk-though with a video recorder, guideline selection with respect to user interface design elements, determination of the properties of the design elements, discussion with the system designers, and a conversion of the properties into a screen design were carried out. This paper describes the process in detail and the findings in the course of the style guide development.

  • PDF

Shaking Table Test to Verify the Seismic Performance of Nuclear Electric Components (원자력 전기기기 부품의 내진성능 확인을 위한 진동대 실험)

  • Chang, Sung Jin;Jeon, Bub Gyu;Park, Dong Uk;Kim, Sung Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.141-147
    • /
    • 2024
  • Earthquakes of magnitude 3.0 or greater occur in Korea about 10 times on average yearly, and the number of earthquakes occurring in Korea is increasing. As many earthquakes have recently occurred, interest in the safety of nuclear power plants has increased. Nuclear power plants are equipped with many cabinet-type control facilities to regulate safety facilities, and function maintenance is required during an earthquake. The seismic performance of the cabinet is divided into structural and functional performances. Structural performance can be secured during the design procedure. Functional performance depends on the vibration performance of the component. Therefore, it is necessary to confirm the seismic performance of the components. Generally, seismic performance is confirmed through seismic simulation tests. When checking seismic performance through seismic simulation tests, it is difficult to determine the effect of frequency and maximum acceleration on an element. In this paper, shaking table tests were performed using various frequencies and various maximum accelerations. The seismic performance characteristics of the functions of electrical equipment components were confirmed through tests.

Composition Technology of Pulsed Power System with High Current (대전류 고속펄스파워시스템의 구성기술)

  • Lee, Hyeong-Ho;Seo, Kil-Soo;Kim, Young-Bae;Cho, Kook-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2179-2181
    • /
    • 1999
  • This paper describes the composition technology of pulsed power system with high current. The capacitor bank, control cabinet, dc charging unit, closing switch and cable system etc. employed with the system components are described. Especially the development of the inverse pinch switch enabled the generation of the very high current.

  • PDF

Effective Protection Methods of Household Electric Appliances. from Lightning Surges (가정용 전기기구의 효과적인 뇌서지 보호기법)

  • 이복희;강성만;엄주홍;이수봉;길형준;구본완;안창환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.149-156
    • /
    • 2004
  • This paper deals with the effective protection method for the household electric appliances against lightning surges invading from the Power lines. Direct or induced lightning is the main cause of the breakdown of household electric appliance. The most effective protection method is to install SPDs(surge protective devices) at household electric appliances. If SPDs were not installed at most household electric appliances, it is necessary to install SPDs on the mains. Therefore the propagation aspect and protection methods of lighting surges coming into household electric appliances through the mains was experimentally investigated. The in actual-sized test circuits results of protection method for 8 household electric appliances including computer monitors and TV set could be summarized as follows: The breakdown characteristics of household electric appliances from lightning surges were significantly changed with the their input impedance. Namely, the types of input impedance are classified into infinite, resistive or inductive impedances. Especially, the monitor for computer with inductive input impedance from lightning surges was relatively weak against lightning surges. It was confirmed that the self inductance of branch circuits on the mains have protection effect for household electric appliances against lightning surges invading from the power lines. Also the varistors installed at cabinet panel or circuit-breaker were more effective than multi-tap outlet with varistors. When installed varistors in cabinet panel and multi-tap outlet together, the surge protection effect is much more excellent in technical and economical aspects.

Operation Test of Control Element Drive Mechanism Using a Power Controller (전력제어기를 이용한 제어봉 구동장치 동작시험)

  • Kim, Choon-Kyung;Lee, Jong-Moo;Jeong, Soon-Hyun;Cheon, Jong-Min;Kweon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.741-743
    • /
    • 2004
  • In this paper, we describe a Control Element Drive Mechanism(CEDM) operation test using a Power Controller. By testing, we can catch the mechanical and electrical characteristics of CEDM and obtain the information about the improvement of CEDM and the design of CEDM power cabinet. The power controller for CEDM introduced in this paper can input firing angles directly into gate drive circuits of thyristors so that this method can be used to derive the maximum and minimum values of firing angles within available limits for a 3-phase half-wave rectifier. Angle inputs help us understand each coil's response characteristics. Since this power controller generates a serial sequence for CEDM insertion and withdrawal operations, we may judge whether CEDM works correctly as expected or not in each phase of a step movement.

  • PDF

Categorization of End-Users' Load Patterns Applied to Dynamically-Administered Critical Peak Pricing (Smart Meter와 부하 패턴 분류를 이용한 Critical Peak Pricing 요금제 적용)

  • Joo, Jhi-Young;Kwon, Sang-Hyeok;Ah, Sang-Ho;Yoon, Yong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.460-462
    • /
    • 2008
  • 일반 수용가를 대상으로 한 효율적인 수요관리의 한 방법으로써 Dynamically-Administered Critical Peak Pricing[1] 요금제를 이용하여 일반 수용가 대상 수요관리를 스마트 미터기인 Smart Cabinet Panel(SCP)를 개발하여 적용하였다. 이 DA-CPP 요금제에는 핵심이 되는 최적 critical peak 시점을 푸는 하위 문제들 및 방법론들이 존재하는데, 우리는 energy service provider(ESP)가 관리해야 할 수용가의 수가 매우 많다는 점에 주목하여, 각 수용가의 1일 부하 사용량 패턴을 몇 개의 그룹으로 나누어 각 그룹에 대해 critical peak 최적 시점을 결정하는 연구를 수행하였다. 이러한 수용가 부하량 패턴그룹화를 위해 인공 지능의 여러 기법 중 하나인 self-organizing map(SOM)을 사용하였다 그리고 ESP와 수음가가 통신할 수 있도록 개발된 SCP를 통해 Critical Peak을 적용하였다.

  • PDF

A Study on Guidelines for the Kitchen Workspace of the Aged (노인을 위한 부엌 작업공간의 계획지침 연구)

  • Kim, Hyun-Jee;Hong, Yi-Kyung;Oh, He-Kyung
    • Journal of Families and Better Life
    • /
    • v.24 no.5 s.83
    • /
    • pp.89-99
    • /
    • 2006
  • The purpose of this study was to devise guidelines for the kitchen workspace of the aged by examining current usage. To achieve this objective, surveys were conducted and measurement were taken between June 15 and lune 30, 2005. The data were gathered from 50 women over 65- years-old who live in the downtown and suburbs of Seoul, Korea. The collected data were processed using SPSS 12.0 for Microsoft Windows and resulted in the following conclusions: The kitchen for the aged needs to be laid out in ㄱ-shape and the refrigerator needs to be positioned prominently. The height of the work counter is relative to the user's height (${\times}0.49{\sim}056$). and the length varies depending on the available space of the house and the type of work counter needed: however it was found that it should be at least 270cm Concerning the depth of the work counter, the standard sizes (60cm) currently on the market did not cause any inconvenience. It was found that the sink must be designed to allow for some space at the bottom so as to ensure comfortable sedentary work. Also, an electrical oven was preferred over a gas-fuelled one. Finally, the height of the upper cabinet should be relative to the user's height at ${\times}0.85{\sim}1.0$ from the floor to the bottom of the cabinet.

저음부의 출력을 위한 voice coil의 질량

  • 이계호
    • 전기의세계
    • /
    • v.14 no.4
    • /
    • pp.22-27
    • /
    • 1965
  • 우리나라의 speaker제작의 역사는 얼마되지 않을 뿐더러 자급자족의 영역을 못 벗어나고 있다. Weston speaker, 자사내에서 자급자족하고 있는 금성사제 speaker등 완전히 질량의 단계에 못들어가고 있는 실정이다. 그나마 성능면에서도 뒤떨어짐을 면할 수 없는 실정이다 .부속품 예컨데 자철 coil접착제등 거이 매매회사에서 직수입하고 있는 형편인것 같다. 물론 종합공업이 발달해야만 되겠기에 단편적 발달은 기하기 어려울 줄 안다. 그러나 speak의 조립 공정에서 끝마치고 있는 형편이고 보면 한심할 지경이다. 물론 speaker제작이라고 하는 것은 극히 delicacy한 면을 가지고 있다. 즉 효율은 $B^{2}$에 비례하는것은 당연하지만 효율을 높이고저 공기부하의 저항을 크게 할려면 corn의 입경이 크게 되므로 자연적으로 진동계의 질량이 크게되며 또 voice coil의 저항을 적게하자니 coil가 필연적으로 굵게되어 길이가 짧게 될 뿐만아니라 air gap 이 크게되어 자속밀도 B가 적게 되는 상반관계가 있다. Cabinet, baffle, corn, corrugation, speaker system등을 가장 합리적으로 설계할 필요가 있다. 이 실험결과를 보고함으로서 speaker연구에 대한 욕구를 갖고 의욕적인 계기가 되었으면 한다. Voice coil 의 turn수를 바뀌었을때 impedance을 측정하였으며 turn수와 음압level 및 주파수 관계를 알아보았다. 그리하여 중형 speaker의 주파수특성을 알아 설계에 기여하고저 한다.

  • PDF