• Title/Summary/Keyword: Electrical Accidents

Search Result 476, Processing Time 0.027 seconds

The Patterns of Accidental Injury in Young Children and Effect of Safety Education on Their Mothers Performance of Preventive Measures (영유아의 사고유형 실태조사와 안전교육 효과 분석)

  • Song In-Ja;Han Jung-Suk
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.55-74
    • /
    • 1998
  • In the past most major accidents resulted in death, but today there is a dramatic increase in the number of people who survive such accidents but who are left with permanent injury. Particularly, children who are inquisitive about their surroundings but immature in their ability to assess danger, are more vulnerable to accidents and their causes as well as to determine attitudes towards prevention. The main objective of the study was to assess the effectiveness of using an accident prevention manual for accident for accident prevention education. The study was a quasi-experimental study using a questionnaire format. The subjects of the study were 393 mothers of children attending six day care centers in Seoul. Data collection was done between May 1 and June 15, 1997. The tools used for the study were a questionnaire developed the researchers and a manual for accident prevention. The collected data were analyzed using SPSS. The results of the study are as follows: 1. Types of accidents included stabbing, bums, falls from heights, choking, falls on slippery surfaces, traffic accidents, drowning, poisoning, and electrical shock in that order of frequency. 2. The main causes of accidents in children were from cosmetics and household medications. 3. The most frequent locations of accidents in the home were the bathroom, kitchen, and stairways in that order. 4. For $90.4\%$ of children safety seats were not used when the ridding in a car. 5. In examining the parents' accident prevention practices, it was found that many parents used only . one electrical outlet for many appliances, tending to overload the electricity lines and that they were not practically concerned bout the flammability of children's pajamas, indicating a less than positive attitude towards fire prevention. 6. The parents had not provided their children with any instruction on accident prevention or on what to do after an accident had occurred. 7. After the use of pamphlet in an accident prevention education program, it was found that there was a statistically significant difference in the degree to which children carried out safety measures (t=14.96, p=.000) and in their safety habits (t=-1.67, p<.1) indicating an effectiveness in this method of education. The results of this study showed that there are many things in a child's environment that can cause accidents and that the possibility of an accident occurring is high. So nurses looking after children should be aware of the need for safety education to prevent accidents in the home and plan to provide appropriate educational material to help parents with this education.

  • PDF

Prediction Principle and System Structure for the Detection of Incipient Electrical Fire (전기화재 예지원리 및 징후검출 시스템 구조)

  • 김창종
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.4
    • /
    • pp.71-77
    • /
    • 1995
  • Electrical fire in residential, commercial, and industrial areas occupies 40 percent of overall fire accidents as of the year of 1994. The causes of most electrical fires were studied and, based on this investigation, the principle of the early detection or prediction of the electrical fires is developed. The basic principle is to early detect electrical arcs or sparks caused by faulty connections and insulation failures. the structure of the prediction system based on microcontroller technique is presented.

  • PDF

LLC Resonant Converter design for Uninterruptible Power Supply Battery Discharger (LLC 공진형 컨버터를 이용한 무정전전원장치 Battery Discharger 설계)

  • Yoo, Kwang-Min;Kim, Seung-Joo;Kim, Kyoung-Dong;Park, Seung-Hee;Byeon, Yong-Seop;Lim, Seung-Beom;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.240-246
    • /
    • 2013
  • An Uninterruptible Power Supply(UPS) is a system designed to deliver energy during accidents that the AC mains is out of its acceptable limits, without interruption of power flow through the load. Battery Discharger is the device to supply high quality power to the Inverter, when accidents occur, such as Power Failure. The Battery Discharger should have a fast response characteristics. The LLC resonant converter for UPS battery discharger is proposed. The proposed Battery Discharger offers substantial improvements in efficiency, size and cost. The proposed Battery Discharger of UPS approach is a good solution for high power applications above KW. To verify the validity of proposed Battery Discharger, simulations and experiments are carried out.

Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City (에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

Evaluation Standards to Diagnosis Cables in Urban Railway Vehicles (도시철도차량 전선의 열화진단 평가기준)

  • Lim, Jea-Yoon;Lee, Jong-Pil;Lee, Dae-Jong;Ji, Pyeong-Shik;Kang, Seong-Hwa;Kim, Hyung-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.268-274
    • /
    • 2010
  • Urban rail transit brings the benefits of various aspects of society. With the advent of fast and large trains, however, risk and scale of accidents have increased. Despite the fact that there is various safety features built into the modern metros, train faults happen from time to time. Especially, as urban railway vehicles in Korea have become deterioration rapidly, more advanced diagnosis methods are required to prevent various accidents. In this paper, we present diagnosis method for electrical wires to guarantee secure driving and authenticity more accurately in urban railway vehicles. Although there are kinds of conventional methods based on insulation resistance measurement and withstand test, it is extremely difficult to effectively diagnose obsolete equipments such as electrical wires and cables not new ones. This study is focused on development of diagnosis method and establishment of evaluation standard for electrical wires in urban railway vehicles.

Prediction of Galloping Accidents in Power Transmission Line Using Logistic Regression Analysis

  • Lee, Junghoon;Jung, Ho-Yeon;Koo, J.R.;Yoon, Yoonjin;Jung, Hyung-Jo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.969-980
    • /
    • 2017
  • Galloping is one of the most serious vibration problems in transmission lines. Power lines can be extensively damaged owing to aerodynamic instabilities caused by ice accretion. In this study, the accident probability induced by galloping phenomenon was analyzed using logistic regression analysis. As former studies have generally concluded, main factors considered were local weather factors and physical factors of power delivery systems. Since the number of transmission towers outnumbers the number of weather observatories, interpolation of weather factors, Kriging to be more specific, has been conducted in prior to forming galloping accident estimation model. Physical factors have been provided by Korea Electric Power Corporation, however because of the large number of explanatory variables, variable selection has been conducted, leaving total 11 variables. Before forming estimation model, with 84 provided galloping cases, 840 non-galloped cases were chosen out of 13 billion cases. Prediction model for accidents by galloping has been formed with logistic regression model and validated with 4-fold validation method, corresponding AUC value of ROC curve has been used to assess the discrimination level of estimation models. As the result, logistic regression analysis effectively discriminated the power lines that experienced galloping accidents from those that did not.

A Study on the safety measures for hydrogen cooling system of 500MW class thermal power plant (500MW급 화력발전소 수소냉각시스템의 안전대책)

  • Kim, Soon-Gi;Yuk, Hyun-Dai;Ka, Chool-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.385-390
    • /
    • 2005
  • This paper provided a counter measures against the troubles and accidents that are likely to take place in the power plant using hydrogen gas as a coolant for the cooling system of the generator. Because of the extremely wide flammability limits of hydrogen in comparison to the other flammable gases, the safety measures against the hydrogen accidents is very important to ensure the normal operation of electric-power facility. This study's purpose was a presentation of standard model of safety management of hydrogen equipments in the coal firing power plant such as following items: 1) providing the technical prevention manual of the hydrogen explosions and hydrogen fires occurring in the cooling system of power generator; 2) the selection of explosion-proof equipments in terms of the risk level of operating environment; 3) the establishment of regulations and counter measures, such as the incorporation of gas leakage alarm device, for preventing the accidents from arising; 4) the establishment of safety management system to ensure the normal operation of the power plant.

  • PDF

Accident Prevention Technology at a Level Crossing (철도건널목 사고방지를 위한 방안 연구)

  • Cho, Bong-Kwan;Ryu, Sang-Hwan;Hwang, Hyeon-Chyeol;Jung, Jae-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2220-2227
    • /
    • 2008
  • The safety equipments of railway level crossing which are installed at intersections between roads and railway lines prevent level crossing accidents by informing all of the vehicles and pedestrians of approaching trains. The intelligent safety system for level crossing which employs information and communication technology has been developed in USA and Japan, etc. But, in Korea, the relevant research has not been performed. In this paper, we analyze the cause of railway level crossing accidents and the inherent problem of the existing safety equipments. Based on analyzed results, we design the intelligent safety system which prevent collision between a train and a vehicle. This system displays train approaching information in real-time at roadside warning devices, informs approaching train of the detected obstacle in crossing areas, and is interconnected with traffic signal to empty the crossing area before train comes. Especially, we present the video based obstacle detection algorithm and verify its performance with prototype H/W since the abrupt obstacles in crossing areas are the main cause of level crossing accidents. We identify that the presented scheme detects both pedestrian and vehicle with good performance.

Improvement of Obstruction Detecting Method at Railroad Crossing by Image Analyze (영상해석을 통한 철도건널목 장애물 검지방법 개선)

  • Song, Hyeon-Sam;Kim, Young-Dal;Lee, Dae-Dong;Shim, Jae-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1444-1450
    • /
    • 2011
  • An analysis of the causes of railroad crossing accidents reveals that most train collision accidents that occur when safety crossing devices are functioning normally occur because vehicles either experience engine failure on the tracks or because drivers were not notified of the coming train, in which case they get trapped on the tracks when the crossing barriers descend. To prevent such an accident, obstacle detection device by using laser beams detecting the presence of obstacle and crossing bar direction controller by moving direction detection sensor using the Earth's magnetic field detection technology are used in the railroad crossing. Despite using the obstacles detector and crossing bar direction controller in the railroad crossing, the equipments for the railroad crossing does not prevent accidents completely. Therefore, this research has studied new method that can detect obstacles through image analyze and alternate existing equipments. There will be excellent effect to be preventing railroad crossing accident by developing a reliable and new obstacle detecting device.

특수건물의 화재현황 및 분석

  • 박창복;김인태
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.10-14
    • /
    • 1996
  • Followings are the analysis of 578 fire accidents occurred at Specific Building In 1995. Fire frequency had been slightly decresed since 1992. In regional, fire accidents in Seoul and Ulsan were higher than the average. Occupational fire frequency order was apartment, factory, buildings over six stories and market place. In addition, the order of life loss was buildings over six stories, apartment and factory. And property loss totaled six times higher than that of Fire Department. Among the causes of fire, electrical fire formed 44.8%, from which we can assume that there were some problems in the investigation of fire causes.

  • PDF