• Title/Summary/Keyword: Electrical Accidents

Search Result 476, Processing Time 0.031 seconds

Clinical and Statistical Analysis with Age in Cases of Pediatric Burn Patients (소아 화상 환자 2,795례에 대한 연령별 임상 통계학적 분석)

  • Cho, Ki-Hyun;Jang, Young-Chul;Lee, Jong-Wook;Koh, Jang-Hyu;Seo, Dong-Kook;Choi, Jai-Ku
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.445-450
    • /
    • 2011
  • Purpose: The objective of this study is to analyze the epidemiological characteristics of pediatric burn patients and to determine the targets for a pediatric burn prevention program. Methods: A retrospective review of all medical records of acute pediatric burn patients (age < 15 years old) admitted to our hospital between January 2005 and December 2009 was performed. Results: 1472 males and 1323 females were investigated, with a male to female ratio of 1.11 : 1. The greatest number of burn patients were those with an age of 1~2 years (1,463, 52.3%). Scalding burn was the most common cause of injury, which accounted for 2183 (78.1%) patients, followed by contact burns (10.5%), flame burn (4.9%), steam burn (3.6%). Especially steam burn was the second cause of injury in the age under 1 year, while flame burn was the second cause of injury in the age over 7 years. During recent 5 years, incidence of flame burn, steam burn, electrical burn gradually decreased. Variation of seasonal incidence is minimal and most of the patients (2,716 cases, 97.2%) had burns less than 20% TBSA (Total body surface area). The median hospital stay was 18.79 days, and the rate of operation was 28.6% with a high rate in electrical burn (76.2%), flame burn (50.0%), steam burn (46.1%). 6 patients died in this series, which yielded a mortality rate of 0.2%. Conclusion: Prevention efforts should reflect recent study results. Focused prevention program and campaign to make people aware of risk factors and their avoidance is required to reduce the number of burn accidents in children.

Evaluation of Chloride Absorption in GGBS Concrete by Impedance Measurements (임피던스 측정을 통한 GGBS 콘크리트의 염화물 흡수 평가)

  • Kim, Jaehwan;Cho, Han-Min;You, Young-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.230-237
    • /
    • 2022
  • It is essential that service life of reinforced concrete structures in economic and safety aspects should be secured. It is well-known that chloride attack is a typical deterioration mechanism in field concrete structures. To prevent serious accidents like collapse, many studies have been conducted to increase resistance of chloride ingress using concrete mixed with GGBS. The usage of GGBS concrete is nowadays mandatory. Since most concretes in the field are unsaturated, study regarding chloride absorption is necessary, but many studies have focused on the chloride diffusion phenomenon. Methods for evaluating chloride absorption are cost and improper in the field. It is necessary to develop a simple method for evaluating chloride absorption in practice. This study evaluated resistance of chloride ingress in GGBS concretes with impedance measurement and absorption test. From the results, it was confirmed that the contents of absorbed chloride were linearly correlated with the measured electrical resistivities (or conductivities) in the concrete. At the end of the test, the electrical conductivities were 250.8 S/m (w/b=0.4) and 303.1 S/m (w/b=0.6) for PC concretes, and 2.6 S/m (w/b=0.4) and 64.4 S/m (w/b=0.6) for GGBS concretes, respectively. Considering influencing factors for chloride absorption and impedance measurement, chloride ingress into concrete is mainly affected by pore structures due to replacement of GGBS. Especially, formations of pore structure are different with binder, thereby binders should be considered in building reinforced concrete structures exposed to chloride environments.

Low price type inspection and monitoring system of lithium ion batteries for hybrid vessels (하이브리드 선박용 리튬 배터리의 저가형 감시시스템 구현)

  • Kwon, Hyuk-joo;Kim, Min-kwon;Lee, Sung-geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.28-33
    • /
    • 2016
  • Batteries are used for main power engine in the fields such as mobiles, electric vehicles and unmanned submarines, for starter and lamp driver in general automotive, for emergency electric source in ship. These days, lead-acid and the lithium ion batteries are increasingly used in the fields of the secondary battery, and the lead-acid battery has a low price and safety comparatively, The lithium ion battery has a high energy density, excellent output characteristics and long life, whereas it has the risk of explosion by reacting with moisture in the air. But Recently, due to the development of waterproof, fireproof, dustproof technology, lithium batteries are widely used, particularly, because their usages are getting wider enough to be used as a power source for hybrid ship and electric propulsion ship, it is necessary to manage more strictly. Hybrid ship has power supply units connected to the packets to produce more than 500kWh large power source, and therefore, A number of the communication modules and wires need to implement the wire inspection and monitor system(WIIMS) that allows monitoring server to transmit detecting voltage, current and temperature data, which is required for the management of the batteries. This paper implements a low price type wireless inspection and monitoring system(WILIMS) of the lithium ion battery for hybrid vessels using BLE wireless communication modules and power line modem( PLM), which have the advantages of low price, no electric lines compared to serial communication inspection systems(SCIS). There are state of charge(SOC), state of health(SOH) in inspection parts of batteries, and proposed system will be able to prevent safety accidents because it allows us to predict life time and make a preventive maintenance by checking them at regular intervals.

A Study of the Intersection in Reduce Car Accidents for Traffic Signal Light to Supplement (교차로 사고 감소를 위한 신호등 보완에 관한 연구)

  • Park, In-Deok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.296-301
    • /
    • 2020
  • Three types of traffic signal systems are two-color signal systems that flash red and green and are mainly used on crosswalks, next, three-color equalization systems mainly used at T-shaped intersections with red and yellow lights and a green arrow, and third, four-color intersections that generally have red, yellow and green colored lights and a green arrow. In what is known as the "dilemma zone" area, a driver collects information that influences his/her decision whether to stop, speed, tail, interrupt, or violate a traffic light, depending on the intersection width, vehicle speed, cognitive response time and reference yellow signal time. This study examined the impact of changes in the length of the dilemma zone areas based on changes in yellow signal times, the speed of the intersection passages, and signal lamps. Downward adjustments of 50km/h and 60km/h affected yellow signal time. The yellow signal time increased by 0.1 to 2.3[s] due to this effect and the dilemma zone area increased by 1.22 to 26[m]. The driver of the dilemma zone could quickly decide to reduce the time remaining of the straight (3color, 4color) green signal to reduce the potential of a traffic accident at the intersection traffic. Safe entry of red (LED palm) and left-turn signals for entering flashed at the intersection and operated at midnight.

Study on Vehicle Deceleration Control in School Zones by Taking Driver's Comfort into Account (스쿨 존에서 운전자의 승차감을 수반한 차량 감속 제어에 관한 연구)

  • Cho, Hyo-Seung;Kim, Hyoung-Seok;Lee, Byung-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1359-1366
    • /
    • 2010
  • Recently, many electronic control techniques for vehicles have been developed and applied. One of the technologies can be X-by-wire such as throttle-by-wire, brake-by-wire, steer-by-wire, and etc, in which most of mechanical parts are replaced into electrical wire and actuators. In this study, the effect of throttle-by-wire and brake-by-wire control systems on vehicle velocity control, especially in a school zone, are taken into consideration. The number of accidents reported in school zones is higher than that in other places. The reason for this is that many vehicle drivers do not obey speed limit regulations. Moreover, some of the students are careless while crossing the streets. Therefore, in this study, we attempt to develop a method using throttle-by-wire and brake-by-wire control systems for automatically reducing the vehicle speed such that it will be within the speed limit. First, an engine model and a transmission system model are developed for a specific vehicle model. Second, speed reduction is carried out such that the reduction follows a pre-designed cubic spline trajectory; the trajectory is determined such that rapid deceleration, which causes discomfort to the driver and passengers, can be prevented, for which a fuzzy-PID control algorithm is applied for the trajectory following control. Finally, simulation results are presented to verify the performance of the proposed speed reduction control system.

Operation Scheduling in a Commercial Building with Chiller System and Energy Storage System for a Demand Response Market (냉각 시스템 및 에너지 저장 시스템을 갖춘 상업용 빌딩의 수요자원 거래시장 대응을 위한 운영 스케줄링)

  • Son, Joon-Ho;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.312-321
    • /
    • 2018
  • The Korean DR market proposes suppression of peak demand under reliability crisis caused a natural disaster or unexpected power plant accidents as well as saving power plant construction costs and expanding amount of reserve as utility's perspective. End-user is notified a DR event signal DR execution before one hour, and executes DR based on requested amount of load reduction. This paper proposes a DR energy management algorithm that can be scheduled the optimal operations of chiller system and ESS in the next day considering the TOU tariff and DR scheme. In this DR algorithm is divided into two scheduling's; day-ahead operation scheduling with temperature forecasting error and operation rescheduling on DR operation. In day-ahead operation scheduling, the operations of DR resources are scheduled based on the finite number of ambient temperature scenarios, which have been generated based on the historical ambient temperature data. As well as, the uncertainties in DR event including requested amount of load reduction and specified DR duration are also considered as scenarios. Also, operation rescheduling on DR operation day is proposed to ensure thermal comfort and the benefit of a COB owner. The proposed method minimizes the expected energy cost by a mixed integer linear programming (MILP).

A Feasibility Study on Developing Snow Melting Systems using CNT-Cement Composite (도로 융설체 개발을 위한 탄소나노튜브-시멘트 복합체 특성에 관한 실험적 연구)

  • Heo, Jinnyung;Park, Bumjin;Kim, Taehyeong
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.29-37
    • /
    • 2013
  • PURPOSES : This study aims to review the possibility of developing a road snow-melting system that can prevent slip accidents by maintaining a constant temperature of the winter roads and enhance performance of structures, including improvement of compressive strength by mixing carbon nanotube (hereafter referred to as CNT) with cement paste, the basic material. METHODS : To achieve the above purpose, an experiment was conducted by mixing power-type CNT and wrap-type CNT up to cement paste formulation by weight of 0.0wt%~4.1wt% in accordance with "KS L ISO 679(of cement strength test method)", and compressive strength was measured at 28 days of curing. In addition, the volume resistivity of the specimen was measured to test thermal and electrical characteristics, and the rate of temperature changes in specimen surface by power consumption was measured by passing electricity through the cross-sections of the specimen. Meanwhile, the criteria for checking the performance as a road snow-melting system was determined as volume resistivity of $100{\Omega}{\cdot}cm$ or less. RESULTS : A comparative analysis between specimen with 0wt% CNT content in plain status and specimen containing various types of CNTs was carried out. From its results, it was found that compressive strength increased approximately 19%, showing the highest rate when 0.2wt% of wrap-type CNT was contained, but volume resistivity of $100{\Omega}{\cdot}cm$ or less appeared only in specimens containing more than 0.2wt% CNT. In addition, it was observed that the surface temperature increased by $4.62^{\circ}C$ per minute on average in specimens containing 3.2wt% CNT. CONCLUSIONS : In this study, CNT was examined as an underlying material for a road snow-melting system, and the possibility of developing the road now-melting system was reviewed by conducting various experiments using CNT-Cement composites. From the experimental results, the specimens were found to have a superior performance when compared to the existing road snow-melting systems that place the heat transfer medium such as copper on the road. However, satisfactory strength performance were not obtained from the specimen containing CNT(2.0% or more) that functions as a heating element, which leads to the need for reviewing methods to increase the strength by using plasticizer or admixture.

Implementation of a Dual-mode Power Strip Controller Cooperating with Smartphones Based on Environmental Sensors (환경센서에 기반한 스마트폰 연동형 듀얼모드 전원 스트립 제어기 구현)

  • Lim, Jae-Hyun;Kim, Jong-Hyun;Jang, Min-Jun;Choi, Yeon-Seung;Cheong, Ho-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.465-467
    • /
    • 2015
  • This paper implements a dual-mode power strip controller (PSCtrl) with environmental sensors which cooperates with Android-based smartphones. According to the statistics on fires in housing facilities, unidentified electrical fires account for 23.4%. In order to reduce these fire accidents caused by user carelessness and protect life and property, smart power control techniques with improved user convenience are required. For this reason, the implemented dual-mode PSCtrl controls ON-OFF operations of a power strip in two ways (e.g. manual and automatic modes) by cooperating with Android-based smartphones provided with environmental data from light, temperature, and humidity sensors. In manual mode, users check environmental data displayed on Android-based smartphones, forcibly controlling the ON-OFF operations through the dual-mode PSCtrl, and in automatic mode, when environmental data exceeds the threshold set by users in advance, the dual-mode PSCtrl automatically controls the ON-OFF operations. Some experimental tests verify successful dual-mode operations of the implemented dual-mode PSCtrl.

  • PDF

Analysis of the Risk of Heat Generation due to Bolt Loosening in Terminal Block Connector Parts (볼트풀림에 의한 터미널 블록의 접속부 발열 위험성 분석)

  • Yeon, Yeong-Mo;Kim, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.67-75
    • /
    • 2020
  • In this study, the risk of heat generation due to normal and overload currents that vary with the abnormal loosening angle of wire-connecting bolts were identified. The risks were analyzed based on the thermal characteristics to minimize the carbonization accidents of terminal blocks inside distribution panels typically used in industrial sites. We applied a method for measuring the heating temperature and temperature variations in the terminal blocks in real-time by installing a resistance temperature detector sensor board in the terminal block. The experimental results showed that the terminal block model with a low-rated current exhibited a higher heating temperature, thus, confirming the need to select the terminal block capacity based on load currents. Additionally, the higher the rated current of the terminal block with a high-rated current and the higher the degree of loosening, the faster the carbonization point. Such heating temperature monitoring enabled real-time thermal temperature measurement and a step-by-step risk level setting through thermal analysis. The results of the measurement and analysis of carbonization risks can provide a theoretical basis for further research regarding the risk of fire due to carbonization. Furthermore, the deterioration measurement method using the temperature sensor board developed in this study is widely applicable to prevent fires caused by poor electrical contact as well as risk-level management.

A Design and Implementation of Busbar Joint and Temperature Measurement System (부스바 접촉 상태 및 온도 감지 시스템 설계 및 구현)

  • Lee, Young-dong;Jeong, Sung-Hak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.2
    • /
    • pp.379-385
    • /
    • 2017
  • In general, distribution board, panel board and motor control center can be installed over a wide area such as residence of group, building, schools, factories, ports, airports, water service and sewerage, substation and heavy industries that are used to supply converts the voltages extra high voltage into optimal voltage. There are electrical accidents due to rise of contact temperature, loose contact between busbar, deterioration of the contact resistance, over temperature of the busbars. In this paper, we designed and implemented the busbar joint and temperature measurement system, which can measure the joint resistance of busbar and loose connection between busbar using potentiometer and non-contact infrared sensor. The experimental results show that tightening the bolt and nut is fully engaged, resistance was decreased and maximum error range was 0.1mm. Also, the experimental result showed that the temperature at the contact area is increased from $27.3^{\circ}C$ to $69.3^{\circ}C$by the contact resistance.