• 제목/요약/키워드: Electric train

검색결과 603건 처리시간 0.031초

절연구간에서의 전력품질 문제가 전기철도에 미치는 영향에 관한 연구 (A Study on an infuence of power quality problem on the electric train at dead section)

  • 이봉이;김재철;문종필
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.92-94
    • /
    • 2005
  • In this paper, when electric train is in dead-section the effect on electric train system was dealt. The feeding system of electrical railway is AC or DC. When the electric train is passed AC feeding system to DC, vice versa or phase is changed in between AC feeding systems, there is a dead section. A dead section usually makes the electrical system complex md may have an adverse effect on the electrical system inside the train. Accordingly, it is important to analyze the effect on trains in dead-section. Modeling an electric train and simulation using PSCAD/EMTDC was accomplished to analyze how power quality problem such as inverter switching surge is propagated to electric train through the feeding line, railway, pantograph.

  • PDF

진동신호를 이용한 전기동차 구동장치의 안전성 평가 (Safety Diagnosis of Electric Train Driving System Using Vibration Signal)

  • 이봉현;최연선
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.929-935
    • /
    • 1998
  • Safety diagnosis of electric train driving system is performed using vibration signals of running electric train. Safety diagnosis is tried on the viewpoints of the appreciation of superannuation and the fault diagnosis of motor, reduction gear and bogie. The appreciation of superannuation is checked by the vibration levels of driving parts and the fault diagnosis is done by analyzing the frequencies of the vibration signals which are measured directly from a running electric train. The results shows that the vibration levels of each parts increase as the train gets older and each parts have their own frequency patterns of the vibration. Vibration propagation path is also investigated using calculated the coherence value between bogie and driving system. As the results, it is known that vibration signal can be utilized successfully for the safety diagnosis of the driving part of electric train.

  • PDF

절연구간 자동전원 절체시스템을 운행하는 전기차량 영향성 연구 (The study on effect of electric train passing automatic changover system in neutral section of electric railway)

  • 홍현표;양상웅;차한주;김철환;이희순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.195-203
    • /
    • 2011
  • This paper is to analysis technical characteristics occured in the eletric train power conversion device passing automatic changover system in neutral section of electric railway. Power conversion devices in electric train are classified according to the current type and voltage type. The results of this study is used to ensure the stability of electric train in neutral section of electric railway.

  • PDF

전기철도의 전자기적합성에 관한 고찰 (Study for electromagnetic compatibility of electric train system)

  • 김민철;이장무;한문섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.883-888
    • /
    • 2005
  • In modern system, electromagnetic environment are going worse with advancing electric and electronic technology, and this electromagnetic environment affect modern electric train system at the point of the safety problem. Therefore, each distributed system that is consisting electric train system have to prove there own electromagnetic compatibility through the field test. These distributed system can be considered as power supply system, signal & communication system and train system. In this study, essential field tests for electromagnetic compatibility of train system based on IEC national standard are suggested.

  • PDF

Train Ethernet Backbone(TEB) 구성에 따른 신뢰도 분석 (Reliability Analysis of Train Ethernet Backbone)

  • 김준교;박재현;오용국;황현철
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.414-416
    • /
    • 2013
  • As the usage of the electric power train increases, the importance of the control network between the electric control devices grows. IEC proposed a revision of IEC-61375, a standard of the networking among electric devices within a train, to adopt Ethernet as a backbone of train network. This paper performed the reliability analysis of three configurations of Ethernet-based networking within a electric power train that are recommended in IEC-61375 standard. The analysis results show that MTTF(mean time to failure) of the redundant configuration is 20,086 hours, which is a about 3 times longer than the linear configuration.

준고속 도시철도의 진동분석 및 저감대책 (Vibration Analysis and Mitigable Countermeasures of Semi High-speed Subway Electric Trains)

  • 박기수;최연선
    • 한국소음진동공학회논문집
    • /
    • 제18권10호
    • /
    • pp.1014-1023
    • /
    • 2008
  • Subway electric trains need to be faster for accommodation of long distance passengers. The faster run of the existing trains results in deterioration of ride quality due to noise and vibration. To reduce the noise and vibration of the electric train, a running test of the electric train was performed and an ADAMS/Rail model was set up to verify the running test results. The experimental results show that the sources of the cabin noise and vibration basically comes from the irregularity of the railroad track and the deterioration of the connection part between cabin and bogie. Consequently for mitigation of noise and vibration of the electric train, the redesign of the center pivot with softer stiffness and the minimization of rail irregularity are necessary. the frequent maintenance of the train will lead to better comport.

지하철용 고속전동차의 진동원 및 개선대책 (Vibration sources and its countermeasures of high speed electric trains for subway)

  • 박기수;최연선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.244-250
    • /
    • 2007
  • The electric train in the first line subway runs faster in the block from Suwon to Cheonan than the general block. The faster run results in the deterioration of ride quality due to the increase of noise and vibration. To reduce the noise and vibration of the electric train, a running test of the electric train was performed in the block from Suwon to Cheonan. The experimental results show that the sources of the noise and vibration basically comes from the irregularity of the railroad track and the connection part between car body and bogie. The possible countermeasure of the high speed electric train can be the reinforcement of the center pivot to have more flexibility and the frequent maintenance of electric train.

  • PDF

틸팅열차(TTX)의 정장품 성능평가 연구 (A Study on Performance Evaluation of On-board Electric Device of TTX(Tilting Train Express))

  • 한성호;이수길;서승일
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.239-242
    • /
    • 2005
  • This paper introduced an approach of improvement of performance of Electric device for EMU type Train like as TTX. The electric equipments are characterized by insulation, Noise, cooling system etc. and Their weight arc decided by these factors. There are two kinds of power source in EMU train. First, DC voltage source, 1500 volt, 750 volt is used for subway system. Second, AC power source 25000 volt is applied to high speed train and existing main lines. Composite material has the protection of inrush current and high frequency noise. We can use this material to minimize weight of train. Additionally we can get energy saving when operator service TTX.

  • PDF

일반철도선로에서의 전동차 시험운행에 대한 고조파 측정연구 (Harmonics Measurement of the Running Test EMU Train in Conventional Railway Lines)

  • 한성호;손진근;김영훈
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.77-83
    • /
    • 2016
  • The electric quality of train is represented by voltage and current harmonics at PT(Ratio 25,000/15/[V]) which is located between pantograph and primary winding of train transformer. In this paper, voltage and current harmonics were measured on the test EMU(electric multiple unit)train with maximum speed of 180km/h in existing railway lines(chungbuk, Taeback, Honam). As a results of test, it is found that the electric quality of train depends on the mostly operation conditions which is accelerating mode and braking mode on each sections. Voltage THD is above all 3[%] and current harmonics is monitored from lowest Harmonic to highest Harmonic in case of accelerating mode. But, highest current harmonics is not monitored in case of breaking mode. The results in this paper can help to stabilize the power device and power converter of the test EMU train.

절연구간운행 고속철도차량 전력품질 특성 분석 (The analysis of power quality characteristics in high speed train through neutral section of catenary system)

  • 홍현표;최의성;이시빈;이희순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.634-643
    • /
    • 2011
  • The neutral section was installed in order to prevent conflict with different phase angle source in electric railway catenary system. The speed of electric train reduced due to coasting operation by notch off when it passed the neutral section. And, the catenary wire was damaged and the accident might be happened because of the arc generation when the electric train passed the neutral section with notch off condition. The inrush current of main transformer installed tiling train is analyzed during the operation of MCB(main circuit break) passing through the neutral section. The instantaneous waveform of load current were analyzed in case of powering and regenerative braking. Inrush current waveform with run of AC railway train showed that inrush current waveform and harmonics, the inrush current generated from main transformer in train has bad effects on power quality problem. In order to reduce these inrush currents, the MCB is connected when the phase angle of voltage is 90 degree. This paper is to measure inrush current and harmonics in main transformer of high speed train in neutral section of electric railway. This measurement report is used to control minimum inrush current in algorithm and power phase angle.

  • PDF