• 제목/요약/키워드: Electric stimulation therapy

검색결과 75건 처리시간 0.03초

The Effects of Isokinetic Exercise on Knee Joint Combined Russian Current Stimulation

  • Kim, Dong-Hoon;Jung, Ho-Bal
    • The Journal of Korean Physical Therapy
    • /
    • 제27권5호
    • /
    • pp.351-355
    • /
    • 2015
  • Purpose: This study was conducted to determine how stimulation using Russian current changes isokinetic exercise performance of quadriceps muscle and its antagonist muscles. Methods: Subjects were 20 20-year-old healthy adults who were instructed in the flexion to extension of knees in angular velocity $60^{\circ}/sec$ and $180^{\circ}/sec$ using a Biodex (Biodex system 3). We measured the difference in muscle performance between the Russian current stimulated at the same time during the flexion to extension of knees and not stimulated. Results: The results showed that when Russian current stimulation was applied at the angular velocity $60^{\circ}/sec$, the flexed and extended muscles and the angular velocity $180^{\circ}/sec$ increased significantly, but the peak torque of flexing muscles at the angular velocity $180^{\circ}/sec$ did not increase. Conclusion: These findings suggest that Russian current stimulation with isokinetic exercise of the knee joint could affect the quadriceps muscle and its antagonist muscle performance of muscle strength and endurance.

침을 이용한 전기자극 통증치료 (Electric Stimulation for Pain Relief Using Acupuncture Needles)

  • 신근만;홍순용;최영룡
    • The Korean Journal of Pain
    • /
    • 제5권1호
    • /
    • pp.52-56
    • /
    • 1992
  • For pain relief my collegue and I used thin acupuncture needles as electrodes in electric stimulation. The needles were inserted into a trigger point and into another point located in the same muscle instead of meridian points of electro-acupuncture. Low frequency electric stimulation was given through the needles to 130 patients for 15 min. The results were as follows In 25 acute sprain patients electric stimulation was given $3.14{\pm}1.12$ times and the pain was reduced on the average by $83.00{\pm}6.77%$ (VAS). In 45 chronic sprain patients electric stimulation was given $5.51{\pm}1.38$ times and the pain was reduced on the average by $70.22{\pm}8.98%$ (VAS). In 28 myofascial pain syndrome patients electric stimulation was given $6.22{\pm}1.25$ times and the pain was reduced on the average by $66.48{\pm}8.75$(%). In 7 muscle contraction headache patients electric stimulation was given $4.14{\pm}1.57$ times and the pain was reduced on the average by $75.00{\pm}9.57%$ (VAS). In 25 radiculopathy patients electric stimulation was given $4.73{\pm}1.131$ times and the pain was reduced on the average by $21.37{\pm}9.31%$ (VAS). We he conclude that electric stimulation therapy using acupuncture needles is very effective in acute sprain, chronic sprain, myofascial pain syndrome and muscle contraction headache. Any doctor with knows anatomy and trigger points can practice this method without studying oriental medicine or difficult acupuncture techniques.

  • PDF

당뇨유발백서에서 피하신경전기자극의 말초신경기능 개선효과 (Improvement of PENS on Peripheral Nerve Conduction Function in STZ-Induced Diabetic Rats)

  • 김양호;장미경;신민철
    • The Journal of Korean Physical Therapy
    • /
    • 제18권4호
    • /
    • pp.19-26
    • /
    • 2006
  • Purpose: This study aimed the effects of percutaneous electric nerve stimulation (PENS) applied to different parts of the streptozotocin-induced diabetic rats on the change of glucose and nerve. Methods: rats (ten weeks old) were selected as the subjects; the normal group was five rats, and the diabetes induction group II, III and IV were five rats, respectively, which were randomly sampled from the twenty-five streptozotocin-administered rats with more than $240\;d{\ell}/m{\ell}$ of blood sugar. For PENS, electric current with 2 Hz of stimulation frequency and $200\;{\mu}s$ of pulse duration was applied to the subjects for fifteen minutes a day, six days a week, for three weeks. Calculation of glucose and weight, and nerve conduction test were conducted forty-eight hours and three weeks after streptozotocin administration, respectively. Results: As for change of glucose and weight, the group III with stimulation to the acupoints and the group IV with stimulation to non-acupoints showed significant differences from the control group II (p<0.05). As for MNCV (motor nerve conduction velocity), the group III with stimulation to the acupoints showed significant differences from the group IV with stimulation to non-acupoints and the control group II (p<0.05). Conclusion: PENS had the effects of inhibiting increase of glucose, change of weight and decrease of nerve conductive function between the distal and proximal ends of the peripheral nerve in the STZ-induced diabetic rats.

  • PDF

경피신경전기자극이 지연성근육통의 교감신경활동에 미치는 영향 (The Effects of Transcutaneous Electrical Nerve Stimulation on Sympathetic Nerve Activity in Delayed Onset Muscle Soreness)

  • 박장성
    • The Journal of Korean Physical Therapy
    • /
    • 제14권1호
    • /
    • pp.109-115
    • /
    • 2002
  • This study conducts eccentric exercise ti non-dominant elbow flexor of 20 persons in order to examine the effects of transcutaneous electric nerve stimulation on sympathetic nerve activity in delayed onset muscle soreness, induces delayed onset muscle soreness, divides them into 10 persons respectively as experimental and control groups. And a stimulation for 2 min. with 100 pps is given to elbow flexor after repeated three times of 10 minutes rest, temperature, blood pressure and pulse are measured and as a result of two-way ANOVA, change of temperature didn't show a significant difference according to the elapse of times(p>0.05) and systolic pressure and pulses in showed a significant difference between experimental and control groups(p<0.05). These results suggest that transcutaneous electrical nerve stimulation has a direct or indirect influence on sympathetic nerve activity in delayed onset muscle soreness under a restricted condition of electrical stimulation.

  • PDF

TENS와 SSP가 전류지각역치 및 통증역치에 미치는 효과 (The Effect of Current Perception Threshold and Pain Threshold through Transcutaneous Electrical Nerve Stimulation and Silver Spike Point Therapy)

  • 윤미정;이완희
    • The Journal of Korean Physical Therapy
    • /
    • 제23권2호
    • /
    • pp.53-59
    • /
    • 2011
  • Purpose: This study was designed to compare the effects of transcutaneous electrical nerve stimulation (TENS) and silver spike point (SSP) therapy on current perception threshold (CPT) and mechanical pain threshold (MPT). Methods: Forty-five healthy adult male and female subjects were studied. Fourteen of them were males and twenty-one were females. Subject were randomly assigned to receive; (1) TENS (80/120 Hz alternating frequency), (2) SSP (3 Hz), or (3) no treatment (control group). Electric stimulation was applied over LI4 and LI11 on acupuncture points of the left forearm for 30 minutes. CPT and MPT were recorded before and after electrical stimulation. The data were analyzed using linear mixed models, with group treated as a between subject factor and time a within-subject factor. Results: At 30 minutes after cessation of electrical stimulation the CPT of C fibers and A${\delta}$fibers was reduced in the TENS group that of C fibers was reduced in the SSP group (p<0.05). After cessation of electrical stimulation, the MPT of C fibers and A${\delta}$fibers increased in the TENS group, and that of A${\delta}$fibers increased in the SSP group (p<0.05). Conclusion: After TENS and SSP stimulation, MPT of C fibers and A${\delta}$fibers were selectively increased. In particular, the TENS group showed increases in both C and A${\delta}$fibers, while the SSP group showed increases only in A${\delta}$fibers.

자침시(刺鍼時) 탄침(彈鍼)의 수기자극(手技刺戟)이 전위변화(電位變化)에 미치는 영향(影響) (A Study on the changes of electric change induced by Tanchim (彈鍼) manipulation during acupuncture therapy)

  • 김용득;김영태;박성섭;박귀종;손인철;김경식
    • Korean Journal of Acupuncture
    • /
    • 제21권4호
    • /
    • pp.1-19
    • /
    • 2004
  • Objectives : To understanding biological mechanism of acupuncture therapy, we have proposed a hypothesis. First of all, there exists electric property in meridian and meridian point. Second of all, energy flowing in meridian is related with electric property. Third of all, there is electronic interaction between the operator who performs acupuncture therapy and the receiver who is given acupuncture therapy. Forth of all, acupuncture effects may depend on the electric capacity which is transferred between the operator and the receiver via acupuncture needle. Methods : Under the hypothesis, we studied the effects of electric change in $ST_{37}(+)\;and\;ST_{39}(-)$ generated by Tanchim (彈鍼) manipulation which was stimulated at $ST_{36}$ point. And compared with data on the changes of electric change from the hand of the operator during acupuncture stimulation. Electric charge induced via acupuncture needle from the operator may be important factor that causes the changes of electric change in meridian and acupoint in the receiver. Therefore we investigated the changes of electric charge induced by the operator using Maclab 400 by the following methods. The one was in stable electric circle condition and the other was in unstable electric circle condition. Results : In this experiments, the changes of electric change from the stimulation type of Tanchim manipulation performed in our lab condition in acupuncture therapy was induced at least three factor, one was the difference of bio-potentials between the operator and the receiver of acupuncture therapy, another was the depth of acupuncture insertion from the skin of the receiver, the other was an electromyogram of the receiver. Conclusion : The data imply that the first factor should make a capacitance current when the operator touched the acupuncture needle which was inserted in the receiver. Therefore, the results suggest that capacitance currents stimulus in electronic view may be important factor in acupuncture therapy between the operator and the receiver of acupuncture therapy.

  • PDF

구강안면영역에서의 경피성 신경자극과 전기침자극요법이 전류인지역치에 미치는 영향 (The Effects of Transcutaneous Electrical Nerve Stimulation and Electroacupuncture Stimulation Therapy on the Current Perception Threshold of Orofacial Region)

  • 정진우
    • Journal of Oral Medicine and Pain
    • /
    • 제24권3호
    • /
    • pp.301-313
    • /
    • 1999
  • 구강안면동통 환자의 치료법으로 널리 쓰이는 전기요법은 연조직과 신경계 구조물에 대한 치료 시 중요한 역할을 담당하고 있다. 저자는 현재 구강안면동통의 치료법으로 널리 쓰이고 있는 전기요법들 중 경피성 신경자극(Transcutaneous electric nerve stimulation)과 전기침자극요법(Electroacupuncture stimulation therapy)이 각각의 신경섬유에 미치는 효과를 평가하고자 정상 성인 남녀 29명에게 경피성 신경자극 및 전기침자극을 시행하고 시행 전 및 시행 후 삼차신경 영역의 3가지 종류($A{\beta}$, $A{\delta}$, C fiber)의 신경섬유의 전류인지역치(CPT) 변화를 측정하여 그 차이점을 분석하였으며 이를 대조군과 비교하였다. 경피성 신경자극 및 전기침자극 모두에서 대조군에 비해 삼차신경 영역의 모든 신경섬유에 걸쳐 고른 전류인지역치의 증가를 나타내었으며, 경피성 신경자극과 전기침자극 후의 전류인지역치 변화량은 서로 유의할만한 차이를 나타내지 않았다. 이는 경피성 신경자극 과 전기침자극 모두 3가지 종류($A{\beta}$, $A{\delta}$, C fiber)의 감각신경섬유의 전류인지역치에 영향을 미치며, 구강안면동통의 감소에 효과적으로 사용될 수 있으리라 생각된다.

  • PDF

자침시(刺鍼時) 압침(押鍼)의 수기자극(手技刺戟)이 전위변화(電位變化)에 미치는 영향(影響) (A Study on the changes of electric charge induced by Apchim (押鍼) manipulation during acupuncture therapy)

  • 송문영;심원보;김영태;백대봉;안성훈;김경식;손인철
    • Korean Journal of Acupuncture
    • /
    • 제22권4호
    • /
    • pp.9-27
    • /
    • 2005
  • Objective : hypothesis. First of all, there exists electric property in meridian and meridian point. Second of all, energy flowing in meridian is related with electric property. Third of all, there is electronic interaction between the operator who performs acupuncture therapy and the receiver who is given acupuncture therapy. Forth of all, acupuncture effects may depend on the electric capacity which is transferred between the operator and the receiver via acupuncture needle. Methods : Under the hypothesis, I studied the effects of electric charge in ST37(+) and ST39(-) generated by Apchim (押鍼) manipulation which was stimulated at ST36 point. And compared with data on the changes of electric charge from the hand of the operator during acupuncture stimulation. Electric charge induced via acupuncture needle from the operator may be important factor that causes the changes of electric charge in meridian and acupoint in the receiver. Therefore we investigated the changes of electric charge induced by the operator using Maclab 400 by the following methods. The one was in stable electric circle condition and the other was in unstable electric circle condition. In this experiments, the changes of electric charge from the stimulation type of Apchim manipulation performed in our lab condition in acupuncture therapy was induced at least three factor, one was the difference of bio-potentials between the operator and the receiver of acupuncture therapy, another was the depth of acupuncture insertion from the skin of the receiver the other was an electromyogram of the receiver. Results :The data imply that the first factor should make a capacitance current when the operator touched the acupuncture needle which was inserted in the receiver. Therefore, the results suggest that capacitance currents stimulus in electronic view may be important factor in acupuncture therapy between the operator and the receiver of acupuncture therapy.

  • PDF

외이전기자극이 슬관절질환 노인의 통증과 보행 및 균형에 미치는 영향 (Effects of Auricle Electric Stimulation on Pain, Gait and Balance in the Old Aged with Knee Joint Disease)

  • 서삼기;조운수;이정우;김용남;정진규;황태연
    • The Journal of Korean Physical Therapy
    • /
    • 제20권2호
    • /
    • pp.11-17
    • /
    • 2008
  • Purpose: This study examined the application of electric stimulation to the auricle acupoint (frequency 2 Hz, stimulation level: noxious) with 30 elderly people over 65 years that received treatment in a rural hospital to determine the influence of pain, gait and balance in the aged with knee joint disease. Methods: The subjects were divided into three groups; the degenerative joint diseases (DJD) group (1 male, 9 females), the total knee replacement (TKR) group (1 male, 9 females) and the control group (1 male, 9 females). Auricualr electrical stimulation (AES) was applied with low frequency, high intensity transcutaneous electrical nerve stimulation for 10 seconds per each point. Results: 1. For the change of pain according to AES, there was interaction in the resting period (p<0.001) and gait (p<0.001) and pain of the DJD group and TKR group was decreased. 2. The range of motion (ROM) of the knee joint showed a significant difference in interaction for each group of elderly people (p<0.001) and the ROM for the DJD group and TKR group of elderly people was increased. 3. In the analysis of gait speed changes, there was a significant difference in interaction for each group of elderly people (p<0.001) and for gait speed in the DJD group and TKR group of elderly people. 4. It was found in the change of static balance that there was a significant difference in interaction for each group of elderly people (p<0.01) and balance capacity in the DJD group and TKR group of elderly people was increased. Conclusion: The aged with knee joint disease have pain, and a decreased function of gait and balance. AES was an excellent treatment for control of pain, and an excellent treatment to enhanced joint functions. AES was useful for improving gait and balance due to decreased pain.

  • PDF

Transcutaneous electrical nerve stimulation, acupuncture, and spinal cord stimulation on neuropathic, inflammatory and, non-inflammatory pain in rat models

  • Sato, Karina Laurenti;Sanada, Luciana Sayuri;da Silva, Morgana Duarte;Okubo, Rodrigo;Sluka, Kathleen A.
    • The Korean Journal of Pain
    • /
    • 제33권2호
    • /
    • pp.121-130
    • /
    • 2020
  • Background: Transcutaneous electrical nerve stimulation (TENS), manual acupuncture (MA), and spinal cord stimulation (SCS) are used to treat a variety of pain conditions. These non-pharmacological treatments are often thought to work through similar mechanisms, and thus should have similar effects for different types of pain. However, it is unclear if each of these treatments work equally well on each type of pain condition. The purpose of this study was to compared the effects of TENS, MA, and SCS on neuropathic, inflammatory, and non-inflammatory pain models. Methods: TENS 60 Hz, 200 ㎲, 90% motor threshold (MT), SCS was applied at 60 Hz, an intensity of 90% MT, and a 0.25 ms pulse width. MA was performed by inserting a stainless-steel needle to a depth of about 4-5 mm at the Sanyinjiao (SP6) and Zusanli (ST36) acupoints on a spared nerve injury (SNI), knee joint inflammation (3% carrageenan), and non-inflammatory muscle pain (intramuscular pH 4.0 injections) in rats. Mechanical withdrawal thresholds of the paw, muscle, and/or joint were assessed before and after induction of the pain model, and daily before and after treatment. Results: The reduced withdrawal thresholds were significantly reversed by application of either TENS or SCS (P < 0.05). MA, on the other hand, increased the withdrawal threshold in animals with SNI and joint inflammation, but not chronic muscle pain. Conclusions: TENS and SCS produce similar effects in neuropathic, inflammatory and non-inflammatory muscle pain models while MA is only effective in inflammatory and neuropathic pain models.