• Title/Summary/Keyword: Electric stations

Search Result 191, Processing Time 0.027 seconds

Improved Design in Fishing Operation System for Small Inshore and Coastal Fishing Vessels -II -Design of a Remote Steering System- (소형 연근해 어선의 조업 시스템 개선에 관한 연구-II -원격 조타 시스템의 설계-)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • A combination steering system was designed to provide the flexibility in controlling the steering wheel in fishing operations of the inshore and coastal fishing vessels. The designed steering system basically is consisted of three driving units, such as a electrically driven hydraulic pump unit with a solenoid control valve, a DC motor driven hydraulic pump unit and a manually driven hydraulic pump unit, and two controllers to provide remote steering on the deck, respectively. The steering torque was measured and analyzed to investigate the dynamic performance of the developed steering system. The steering system showed excellent linearity between the working pressure of cylinder and the torque of rudder post in case of increasing in rudder angle from $5^{\circ} to 35^{\circ}$ that is, the steering torque increased from $10.4 kgf{\cdot}m$ to $105.3 kgf{\cdot}m$ and then the working pressure of cylinder fluctuated from 6.3 kgf/cm super(2) to 16.4 kgf/cm super(2). The steering time of 3.2 sec in remote hydraulic steering by the on/off solenoid valve control was much faster than 13.2 sec in the manual steering by the helmsman and 11.6 sec in the electric steering by a DC motor, and then it was verified that operation of one unit does not affect other units in combination steering system in any way. Furthermore, the developed steering system can be remotely controlled in multiple stations of the deck during the fishing operation and the automatic pilot steering unit can be used to add hydraulic steering.

  • PDF

A Study on Stigma Effect of Unwelcomed Facilities on Apartment Prices: A Case Study of Sang-gye Jugong Apartment Complexes in Nowon-gu, Seoul (도시 비선호시설이 주변 아파트 가격에 미치는 낙인효과에 관한 연구 - 서울 노원구 상계동 주공 7, 9, 10단지를 사례로 -)

  • Kim, Chul-Joong;Song, Myung-Gyu
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.2
    • /
    • pp.297-314
    • /
    • 2012
  • This study investigates the stigma effect of unwelcomed facilities on apartment prices through multiple regressions based on hedonic price method. The areas studied are Sang-gye Jugong 7, 9, 10 apartment complexes. The facilities analyzed are the Chang-dong Electric Subway Depot and the Do-bong Driver's License Agency. The factors studied include the environmental variable (the elapsed time since the announcement of the re-location of these facilities), the view commanding, the distance from Chang-dong Depot, the distance from Do-bong Driver's License Test Course, the distance from neighboring facilities (subway stations, schools, parks and so on), the floor and each dwelling's exclusive space. The data used are 2,822 sales which have been collected since January 1, 2006. The facts found are as follows; first, the view commanding and the distance from the unwelcomed facilities are statistically significant. second, the environmental variable, 'days' turns out to have a positive (+) and a negative (-) significant relationship with the dependent variable, 'price', in period II and period IV respectively. This implies that the stigma effect is real. third, there are significant differences in the influence on the apartment prices among the independent variables according to time. fourth, the stigma effect is estimated as 33,686,920 Korean won in the case of the apartments which have the view commanding and 30,311,844 won in the other case before the global economic crisis. This effect seems to decrease to 22,085,078 won after the crisis. These facts suggest that stigma effects could be considered as one of the benefits in the cost-benefit analysis of Chang-dong Depot re-location project to produce somewhat higher NPV or B/C ratio.

Energy saving control system of wireless base station utilizing natural air-conditioning (자연공조를 활용한 무선기지국 Energy절감 제어시스템)

  • Ryu, Gu-Hwan;Kwon, Chang-Hee
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.223-232
    • /
    • 2019
  • With the development of the information communication industry, the size of the communication device has been reduced to a system that generates a large amount of heat. Therefore, since the amount of heat generated by the wireless equipment is large in the wireless base station, the energy consumption is continuously consumed and the failure of the wireless base station may occur. Therefore, in this study, The study was analyzed. As a research method, we performed base station with a lot of calorific value and electric charge. We selected 25 base stations and obtained data for two weeks. To ensure reliability, the room temperature was kept constant at $27^{\circ}C$, and the control system was installed and equiped for two weeks to obtain the date analysis. In order to calculate the test results in the study method, the instrument was used with a computer, a digital thermometer, and dust measurement. For the date analysis, we conducted a research study on 25 wireless basestations before and after the installation of Control Sysetm.

A Study on Safety Impact Assessment of a Multiple Hydrogen Refueling Station (다차종 동시 충전을 위한 수소 스테이션의 안전 영향 평가 연구)

  • Boo-Seung Kim;Kyu-Jin Han;Seung-Taek Hong;Youngbo Choi
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.85-99
    • /
    • 2024
  • As the proliferation of hydrogen electric vehicles accelerates, there is observed diversification in hydrogen refueling station models. This diversification raises safety concerns for different types of stations. This study conducted a quantitative risk assessment of a multi-vehicle hydrogen station, capable of simultaneously refueling cars, buses, and trucks. Utilizing Gexcon's Effects&Riskcurves Software, scenarios of fire and explosion due to hydrogen leaks were assessed. The study calculated the impact distances from radiative heat and explosion overpressure, and measured risks to nearby buildings and populations. The largest impact distance was from fires and explosions at dispensers and high-pressure storage units. High-pressure storage contributes most significantly to personal and societal risk. The study suggests that conservative safety distances and proper protective measures for these facilities can minimize human and material damage in the event of a hydrogen leak.

Study on the Relations to Estimate Instrumental Seismic Intensities for the Moderate Earthquakes in South Korea (국내 중규모 지진에 대한 계측진도 추정식 연구)

  • Yun, Kwan-Hee;Lee, Kang-Ryel
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.323-332
    • /
    • 2018
  • Recent two moderate earthquakes (2016 $M_w=5.4$ Gyeongju and 2017 $M_w=5.5$ Pohang) in Korea provided the unique chance of developing a set of relations to estimate instrumental seismic intensity in Korea by augmenting the time-history data from MMI seismic intensity regions above V to the insufficient data previously accumulated from the MMI regions limited up to IV. The MMI intensity regions of V and VI was identified by delineating the epicentral distance from the reference intensity statistics in distance derived by using the integrated MMI data obtained by combining the intensity survey results of KMA (Korea Meteorological Administration) and 'DYFI (Did You Feel It)' MMIs of USGS. The time-histories of the seismic stations from the MMI intensity regions above V were then preprocessed by applying the previously developed site-correction filters to be converted to a site-equivalent condition in a manner consistent with the previous study. The average values of the ground-motion parameters for the three ground motion parameters of PGA, PGV and BSPGA (Bracketed Summation of PGA per second for 30 seconds) were calculated for the MMI=V and VI and used to generate the dataset of the average values of the ground-motion parameters for the individual MMIs from I to VI. Based on this dataset, the linear regression analysis resulted in the following relations with proposed valid ranges of MMI. $MMI=2.36{\times}log_{10}(PGA(gal))+1.44$ ($I{\leq}MMI$$MMI=2.44{\times}log_{10}(PGV(kine))+4.86$ ($I{\leq}MMI$$MMI=2.59{\times}log_{10}(BSPGA(gal{\cdot}sec))-1.02$ ($I{\leq}MMI$

An Optimizing Simulation for Designing the Numbers of Electric Train Car (전동열차 편성량수 설계를 위한 최적화 시뮬레이션)

  • Kim, Ick-Hee;Yun, Dong-Hee;Kum, Ki-Jung;Lee, Sang-Myoung
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.3
    • /
    • pp.95-106
    • /
    • 2012
  • The railway service in the Seoul metropolitan area is facing variety of l changes such as extension of service coverage, new construction, and introduction of express service which in turn causes changes on demands. The demand affects train operation characteristics (frequency of service, train formation) as well as on the congestion rate which is one of the major evaluation index in metropolitan area user service. For the efficient operation of the train, the relationship among the minimization of fleet number, operating cost, and service level has been analyzed. Using the Powersim, which is a system dynamics (System Dynamics) simulation program for realizing optimized simulation for train-formation, this paper identified that some stations of Gyeong-bu line exceeded limit congestion rate(150%) of a fleet already that means it is best to maintain current condition of the line; however, the Gyeong-in line and the Gwa-chon line showed no excess of the limit congestion rate so that it is possible to reduce 2-4 fleets of train for efficient operation. In addition, in case of Jang-hang line between Cheon-an and Sin-chang, a train consisting of 10 fleets provides services which is same formation of train for Gyeong-bu line. This study proved that the congestion rate will not rise greatly with only 4 fleets of a train for the service in Jang-hang line, and it is considered that a study for shuttle service between Cheon-an and Sin-chang is necessary.

A Study of Detainees' Perceptions of the Detention Facilities of the Police Station and their Operation (경찰서 유치장 시설 및 운영에 관한 유치인의 인식연구)

  • Jung, Woo-Yeoul;Park, Dong-Kyun;Kim, Do-Kyun
    • Korean Security Journal
    • /
    • no.13
    • /
    • pp.423-449
    • /
    • 2007
  • This research is to investigate the detention facilities of police stations and their real operations through the perceptions of detainees at police station cells and to present the policy suggestions for them. To fulfill the research, a questionnaire was made out on the basis of 'the Regulation on Detention and Escort for Suspects'. 'the Regulation on a Standard Plan for Detention Facilities' and 'the Regulation on the Lowest Standard to Treat Detainees' ; and detainees at 23 police station cells under the jurisdiction of Kyungbuk Local Police Agency were asked to answer it. Policy suggestions following from the result of the investigation of detainees' perceptions of the detention facilities of the police stations are as follows; Firstly, the structure of police station cells should be arranged in straight lines in order to take their human rights into consideration and more detention facilities are needed to be built in order to separate male, female, handicapped and juvenile inmates. Secondly, shower rooms and washrooms outside the cells should always be open to detainees whenever they need to be used. Thirdly, any detention facilities deficient in fire fighting equipment should have exit doors installed as soon as possible in case of an emergency and provide sufficient fire extinguishers considering the number of detainees and the size of the facilities. Fourthly, the detention facilities should have sufficient windows for ventilation and take necessary measures to obtain natural lighting instead of electric lighting. Fifthly, air conditioners should be equipped properly taking account of the number of detainees and the dimensions of the facilities. Policy suggestions according to the result of the investigation of detainees' perceptions of the operation of detention facilities of police stations are as follows; Firstly, the problem of operating the detention facilities must deal with worn-out facilities and measures to secure the budget should be taken as soon as possible. Secondly, considering that most detained suspects have difficulties in livelihood, daily necessaries must be issued to them. Thirdly, personal belongings deposited by inmates must be properly managed with the same documentation throughout the police station detention facilities. The number of female guards to take exclusive charge of the physical checkups and processing of female detainees should be increased. Also the facilities for handicapped detainees must be expanded, improved and managed properly. Fourthly, except for handcuffs and ropes to bind detainees in the detention facilities, helmets to prevent self-harm must be withdrawn. The budget to improve the quality of meal issued by the government must be urgently secured and the price of private food sent to detainees must be readjusted to be in line with the consumer price. Health and medical care and sanitation for detainees must be substantial, and also sunbathing and outdoor exercises should be allowed to detainees.

  • PDF

A Study on the Necessity of Introducing Evacuation Instrument in High-rise Buildings - Focusing on Elevator Type Evacuation Instrument - (고층건축물의 피난기구 도입 필요성에 관한 연구 - 승강식피난기를 중심으로 -)

  • Choi, Kyu-Chool;Ra, Pan-Ju;Seul, Yeong-Mi
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.10-19
    • /
    • 2014
  • The fast evacuation from fire floors to evacuation floors in high-rise building fires can minimize the human damage. In this study, an evacuation instrument, which are applicable to the high-rise buildings of adaptable escape mechanisms by the current NFSC 301 (national fire safety code 301), were selected to analyze the applicability in the high-rise buildings over 11th floor through the site adaptability test. The results of the site test were as follows. The elevator type evacuation instrument of new concept developed as a new technology by compensating the defect of evacuation instrument limiting in the high-rise buildings over 11th floor had completed the stability test and the performance certification test in fire stations, which there were no problems in the introduction of the elevator type evacuation instrument as an escape mechanism in the high-rise buildings. The elevator type evacuation instrument using escapers' weight without using electric power was an escape mechanism that many people could evacuate in a short period of time when a fire broke out in the high-rise buildings. In particular, The elevator type evacuation instrument operated by nonpower had the adaptability as a customized escape mechanism considering user characteristics in the buildings for the disabled or patients with an advanced disease.

Study on the Passive IMD Improvement of RF DIN Connectors (RF DIN Connector의 Passive IMD 개선에 관한 연구)

  • Ko, Yun-Sun;Chung, Jae-Pil;Oh, Chang-Heon;Shin, Dong-Uk
    • Journal of Advanced Navigation Technology
    • /
    • v.6 no.3
    • /
    • pp.195-202
    • /
    • 2002
  • Recently, as the range of mobile communication services is extended, the interference between adjacent base-stations is increased. Nowdays, one of the important factors causing interference is IMD (Inter-Modulation Distortion) problems. Not only active IMD but also passive IMD effects must be considered to design a CDMA system. In this study, we design and implement 7/16" DIN connectors which have a various intensity of surface illumination, thickness and quality of plating material to analyze the effects of PIMD. And propose the methods for improving the PIMD characteristics: First, it is more profitable to use the metal which has good intensity of surface illumination where most of all electric currents passes through it. Secondly, we should plate metals more than $5{\mu}m$ for RF energy enough to propagate in a medium. Thirdly, it is necessary to select a metal having high conductivity and specific heat to protect the aging phenomenon of plate material. And it is required to develop a new plating material to replace the current materials, such as the alloy of three components for cost reduction. We have to know that the plate which has intensity of surface illumination 6 S and the thickness of plating material $5{\mu}m$ satisfy the domestic PIMD specification (KTF) -150 dBc, regardless of the plate material in case of 7/16" DIN connector.

  • PDF

Evaluation of Chromosomal Alteration in Electrical Workers Occupationally Exposed to Low Frequency of Electro Magnetic Field (EMFs) in Coimbatore Population, India

  • Balamuralikrishnan, Balasubramanian;Balachandar, Vellingiri;Kumar, Shanmugam Suresh;Stalin, Nattan;Varsha, Prakash;Devi, Subramaniam Mohana;Arun, Meyyazhagan;Manikantan, Pappuswamy;Venkatesan, Chinnakulandhai;Sasikala, Keshavarao;Dharwadkar, Shahnaz N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2961-2966
    • /
    • 2012
  • Extremely low frequency electro magnetic fields (EMFs) have been classified as possibly carcinogenic to humans by the International Agency for Research on Cancer. An increased number of chromosomal alterations in peripheral lymphocytes are correlated with elevated incidence of cancer. The aim of the present study was to assess occupationally induced chromosomal damage in EMF workers exposed to low levels of radiation. We used conventional metaphase chromosome aberration (CA) analysis and the micronucleus (MN) assay as biological indicators of non ionizing radiation exposure. In the present study totally 70 subjects were selected including 50 exposed and 20 controls. Informed written consent was obtained from all participants and the study was performed in accordance with the Declaration of Helsinki and the approval of the local ethical committee. A higher degree of CA and MN was observed in exposed subjects compared to controls, the frequency of CA being significantly enhanced with long years of exposure (P<0.05). Moreover increase in CA and MN with age was noted in both exposed subjects and controls, but was significantly greater in the former. The results of this study demonstrated that a significant induction of cytogenetic damage in peripheral lymphocytes of workers occupationally exposed to EMFs in electric transformer and distribution stations. In conclusion, our findings suggest that EMFs possess genotoxic capability, as measured by CA and MN assays; CA analysis appeared more sensitive than other cytogenetic end-points. It can be concluded that chronic occupational exposure to EMFs may lead to an increased risk of genetic damage among electrical workers.