A Study on Anti-Icing Technique for Weather-Tight Door of Ice-Strengthened Vessels (내빙선박용 풍우밀 문의 결빙방지 기법 연구)

  • Jeong, Seong-Yeob;Chun, Eun-Ji;Cho, Seong-Rak;Lee, Chun-Ju
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.6
    • /
    • pp.575-580
    • /
    • 2011
  • Icing problem of ice-strengthened vessels is an important issue when operating in low temperature environment and it can cause damage to deck machineries and emergency equipments. Many ice-strengthened vessels have since been constructed and operated in accordance with the ice class rules such as Det Norske Veritas (DNV), Russian Maritime Register of Shipping (RS), American Bureau of Shipping (ABS) and so on. Therefore winterization is defined as the preparation of a ship for safe operation. In this research, anti-icing performance tests of weather-tight door have been carried out at various temperature conditions($5^{\circ}C$, $-10^{\circ}C$, $-20^{\circ}C$, $-30^{\circ}C$, $-40^{\circ}C$) in the low temperature cold room facility and then, ambient temperature, specimen temperature, electric current and temperature of heating cable were measured during the test operations. This research describes the construction guidelines of weather-tight door based on anti-icing test results to apply to the full-scale vessels.

Statistical Characteristics of Pollutants in Sterm Flow (하천오염인자의 통계적 특성)

  • 황임구;윤태훈
    • Water for future
    • /
    • v.14 no.4
    • /
    • pp.19-26
    • /
    • 1981
  • The auto-and cross-correlation function, power spectrum, coherence function and Markov model are applied to investigate the statistical characteristics of discharge and each factor of water quality and the interrelation-ship between the variation of discharge and water quality factors. The analysis of discharge, dissolved oxygen and electric conductivity, which were only obtainable data at the Indogyo gagining station in the downstream of the Han River, clearly showed that they hace distinct period of 12 months and three different periods of 6, 4 and 3 months weaker than the former. The cross-correlation between the discharge and water quality(DO, COND) is rather weak and the crosscorrelation function has its peak at lag one. It is considered therefrom that the variation of discharge behaves on water quality facotrs with one day's difference. In the examination of linear regression model for the serial generation and predictive measures, discharge series is fit to first and second order Markov model and DO, COND to first order Markov model.

  • PDF

Experimental Study on Energy Saving through FAN Airflow Control in the Generator Room of a 9200-ton Training Ship (9200톤급 실습선 발전기실 FAN 송풍유량 제어를 통한 선박에너지 절약에 관한 실험적 연구)

  • Moon-seok Choi;Chang-min Lee;Su-jeong Choe;Jae-jung Hur;Jae-Hyuk Choi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.697-703
    • /
    • 2023
  • As a part of the global industrial efforts to reduce environmental pollution owing to air pollution, regulations have been established by the International Maritime Organization (IMO). The IMO has implemented various regulations such as EEXI, EEDI, and CII to reduce air pollution emissions from ships. They are also promoting measures to decrease the power consumption in ships, aiming to conserve energy. Most of the power used in ships is consumed by electric motors. Among the motors installed on ships, the engine room blower that takes up a significant load, operates at a constant irrespective of demand. Therefore, energy savings can be expected through frequency control. In this study, we demonstrated the efficacy of energy savings by controlling the frequency of the electric motor of the generator blower that supplies combustion air to the generator's turbocharger. The system was modeled based on the output data of the turboharger outlet temperature in response to the blower frequency inpu. A PI control system was established to control the frequency with the target being the turbocharger outlet temperature. By maintaining the turbocharger design standard outlet temperature and controlling the blower frequency, we achieved an annual energy saving of 15,552kW in power consumption. The effectiveness of energy savings through frequency control of blower fans was verified during the summer (April to September) and winter (March to October) periods. Based on this, we achieved annual fuel cost savings of 6,091 thousand won and reduction of 8.5 tons of carbon dioxide, 2.4 kg of SOx, and 7.8 kg of NOx air pollutants on the training ship.

Site Monitoring of Crews and Passengers on Board by the BLE and PLM Combination (BLE와 PLM 조합의 승선자 위치 모니터링)

  • Kwon, Hyuk-Joo;Yang, Hyun-Suk;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.463-467
    • /
    • 2015
  • When unforeseen accidents occur in a ship, it is important to save passengers safely and remove them from the accident area quickly. To solve such a situation, site information of passengers on board always must be identified. This paper implemented a site monitoring of crews and passengers based on the BLE and PLM combination, to prepare for unexpected accidents of the ships. This system was composed of BLE tag for crews, passengers and each room, PLM networks, data server, and monitoring PC. In this system, site information derived from the tag attached to the bodies and cabins of crews and passengers are transmitted through a power line network, and monitored on the screen of a monitoring PC. The proposed system guides them into the only authorized area considering the ship security and passengers' safety, and even has a special alarm call to warn them after entering an unauthorized area. This system enables the BLE-embedded tag battery to use for a long time because the BLE consumes low electric power, and can gain an economic advantage.

Electromagnetic Interference of GMDSS MF/HF Band by Offshore Wind Farm (해상풍력 발전단지에 의한 GMDSS MF/HF 대역 전자파 간섭 영향 연구)

  • Oh, Seongwon;Park, Tae-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.47-52
    • /
    • 2021
  • Recently, the share of wind power in energy markets has sharply increased with the active development of renewable energy internationally. In particular, large-scale wind farms are being developed far from the coast to make use of abundant wind resources and to reduce noise pollution. In addition to the electromagnetic interference (EMI) caused by offshore wind farms to coastal or air surveillance radars, it is necessary to investigate the EMI on global maritime distress and safety system (GMDSS) communications between ship and coastal stations. For this purpose, this study investigates whether the transmitted field of MF/HF band from a ship would be subject to interference or attenuation below the threshold at a coastal receiver. First, using geographic information system digital maps and 3D CAD models of wind turbines, the area of interest is electromagnetically modeled with patch models. Although high frequency analysis methods like Physical Optics are appropriate to analyze wide areas compared to its wavelength, the high frequency analysis method is first verified with an accurate low frequency analysis method by simplifying the surrounding area and turbines. As a result, the received wave power is almost the same regardless of whether the wind farms are located between ships and coastal stations. From this result, although wind turbines are large structures, the size is only a few wavelengths, so it does not interfere with the electric field of MF/HF distress communications.

A Study on the Improvement of the Logistics System for Heavy-goods Maintenance in Navy Ship (해군함정 중량형 정비품 물류체계 개선에 관한 연구)

  • Jang, Ji-Hwan;Kim, Hwan-Seong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2020.11a
    • /
    • pp.163-164
    • /
    • 2020
  • Along with the increase in global volume of goods, logistics companies are trying to reduce costs by increasing the size of ships carrying cargo, increasing the efficiency of quantitative equipment at ports, and unmanned electric vehicles on land. Korean naval ports are also facing the same situation as the global trend. In the past, small and medium-sized ships such as FF, PCC, and beheaded eagles are being retired for their longevity, and their positions are being replaced by large ships such as KDX, FFG, and LST-II. In particular, large ships such as Dokdo and the next light aircraft carriers are also being prepared. Unlike general merchant ships, naval ships require periodic inspections and preventive maintenance, so repair piers such as maintenance depots are in operation. The naval maintenance depot mainly uses trailers, trucks, and truck-type cranes to carry out loading and unloading of heavy ships, and the application or development of automation and unmanned equipment performed by the private sector is inadequate, and self-improvement cases are also very weak. This study aims to improve the efficiency of the military logistics system through research on the logistics system such as transport, storage and unloading of heavy goods and maintenance products of naval ships.

  • PDF

Study on Optimum Water Supply by Solar Radiation in Cut Rose(Rosa hybrida cv Cardinal) (일사비례제어에 의한 절화장미(Rosa hybrida cv Cardinal)의 급액량 구명)

  • Na, Taek-Sang;Kim, Jeung-Gun;Choi, Kyong-Ju;Gi, Gwang-Yeon;Yoo, Yong-Kweon
    • Journal of Bio-Environment Control
    • /
    • v.17 no.3
    • /
    • pp.215-220
    • /
    • 2008
  • This study was carried out to find optimum accumulative solar radiation in 'Carnidal' of Perlite Media. The pH was stable from 6.0 to 6.7 during cultivation. Electric conductivity by drainage was higher water than by supply water and electric conductivity was increased at later. Inorganic compound, such as phosphoric, kalium and magnesium were accumulated in crossed system. Especially, kalium and magnesium were highly accumulated. When solar radiation high, consumption of the amount of nutrient solution were increased. Sap flew was $273g{\cdot}hr^{-1}$ per hour from 10 : 30 to 11 : 00 AM. However there was no relation-ship between solar radiation and the mount of sap flew. When amount of solar radiation was $250W{\cdot}hr^{-1}$, cut rose 'Cardinal' nutrient consumption was 212.8 mL at nutrient supply of 50 mL. The yield of cut rose 'Cardinal' was 154.6 ea/10a in perlite media. In the cut rose 'Cardinal', nutrient solution was 50 mL as supplied at solar radiation of $200W{\cdot}hr^{-1}$ and nutrient solution was 30mL as supplied at solar radiation of $250W{\cdot}hr^{-1}$ at low solar radiation in perlite.

Greenhouse Gas Reduction by Air Quality Management Policy in Gyeonggi-do and Its Co-benefit Analysis (경기도 대기질 개선 정책의 온실가스 동시 저감 및 그에 따른 공편익 효과 분석)

  • Kim, Dong Young;Choi, Min-Ae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.570-582
    • /
    • 2017
  • In recent years, national and local government's air quality management and climate change adaptation policy has been significantly strengthened. The measures in the two policies may be in a relationship of trade-off or synergy to each other. Greenhouse gases and air pollutants are mostly emitted from the same sources of using considerable amounts of fossil fuels. Co-benefits, in which either measure has a positive effect on the other, may be maximized by reducing the social costs and by consolidating the objectives of the various policies. In this study, the co-benefits were examined by empirically analyzing the effects of air pollutants and greenhouse gas emission reduction, social cost, and cost effectiveness between the two policies. Of the total 80 projects, the next 12 projects generated co-benefits. They are 1) extend restriction area of solid fuel use, 2) expand subsidy of low-$NO_x$ burner, 3) supply hybrid-vehicles, 4) supply electric-vehicles, 5) supply hydrogen fuel cell vehicles, 6) engine retrofit, 7) scrappage of old car, 8) low emission zone, 9) transportation demand management, 10) supply land-based electric of ship, 11) switching anthracite to clean fuel in private sector, 12) expand regional combined-energy supply. The benefits of air pollutants and greenhouse gas-related measures were an annual average of KRW 2,705.4 billion. The social benefits of the transportation demand management were the highest at an annual average of KRW 890.7 billion, and followed by scrappage of old cars and expand regional combined-energy supply. When the social benefits and the annual investment budgets are compared, the cost effectiveness ratio is estimated to be about 3.8. Overall, the reduction of air pollutants caused by the air quality management policy of Gyeonggi-do resulted in an annual average of KRW 4,790.2 billion. In the point sources management sector, the added value of $CO_2$ reduction increased by 4.8% to KRW 1,062.8 billion, while the mobile sources management sector increased by 3.6% to KRW 3,414.1 billion. If social benefits from $CO_2$ reduction are added, the annual average will increase by 7.2% to KRW 5,135.4 billion. The urban and energy management sectors have shown that social benefits increase more than twice as much as the benefits of $CO_2$ reduction. This result implies that more intensive promotion of these measures are needed. This study has significance in that it presents the results of the empirical analysis of the co-benefits generated between the similar policies in the air quality management and the climate change policy which are currently being promoted in Gyeonggi-do. This study suggested that the method of analyzing the policy effect among the main policies in the climate atmospheric policy is established and the effectiveness and priority of the major policies can be evaluated through the policy correlation analysis based on the co-benefits. It is expected that it could be a basis for evaluation the efficiency of the climate change adaptation and air quality management policies implemented by the national and local governments in the future.

Theoretical Study on Fuel Savings of Marine Diesel Engine by Exhaust-Gas Heat-Recovery System of Combined Cycle (복합 사이클의 배기가스 열회수 시스템에 의한 선박용 디젤엔진의 연료 절약에 관한 이론적 연구)

  • Choi, Byung Chul;Kim, Young Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.171-179
    • /
    • 2013
  • The thermodynamic characteristics of a combined cycle applied with a topping cycle such as a trilateral cycle at relatively high temperatures and a bottoming cycle such as an organic Rankine cycle at relatively low temperatures have been theoretically investigated. This is an electric generation system used to recover the waste heat of the exhaust gas from a diesel engine used for the propulsion of a large ship. As a result, when the boundary temperature between the topping and the bottoming cycles increased, the system efficiencies of energy and exergy were simultaneously maximized because the total exergy destruction rate (${\sum}\dot{E}_d$) and exergy loss ($\dot{E}_{out2}$) decreased, respectively. In the case of a marine diesel engine, the waste heat recovery electric generation system can be utilized for additional propulsion power, and the propulsion efficiency was found to be improved by an average of 9.17 % according to the engine load variation, as compared to the case with only the base engine. In this case, the specific fuel consumption and specific $CO_2$ emission of the diesel engine were reduced by an average of 8.4% and 8.37%, respectively.

Electrode bonding method and characteristic of high density rechargeable battery using induction heating system (유도 가열 접합 시스템을 이용한 대용량 이차전지 전극의 접합 방법 및 특성)

  • Kim, Eun-Min;Kim, Shin-Hyo;Hong, Won-Hee;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.688-697
    • /
    • 2014
  • In this study, electrode bonding technology needed for high density of rechargeable battery is studied, which is recently researched for electric vehicle, the small leisure vessel. For the alternative overcoming the limit of stacking amount able to be stacked by conventional ultrasonic welding, the low temperature bonding method, eligible for minimum of degeneration of chemical activator on the electrode surface which is generated by thermal effect as well as the increase of conductivity and tension strength caused by electrode bonding using filler metal, not using conventional direct heating on the electrode material method, is studied. Specifically to say, recently used more generally the ultrasonic welding and spot welding method are not usable for satisfying stable electric conductivity and bonding strength when much electrode is stacking bonded. If the electrical power is unreasonably increased for the welding, due to the effect of welding temperature, deformation of electrode and activating material degeneration are caused, and after the last packaging, decline of electrical output and generating heat cause to reduce stability of battery. Therefore, in this study, induction heating system bonding method using high frequency heating and differentiated electrode method using filler metal pre-treatment of hot dipping are introduced.