• Title/Summary/Keyword: Electric sensor

Search Result 1,154, Processing Time 0.025 seconds

Environmental save of the Gosu cave and the saving management plan of electronic (고수동굴의 환경보존과 전기의 효율적 관리 방안)

  • Yoon, Jung-Mo
    • Journal of the Speleological Society of Korea
    • /
    • no.86
    • /
    • pp.25-30
    • /
    • 2008
  • The black pollution that was able to include green pollution to appear for the intensity of light by an illumination institution is what after all I cannot ignore, and it may be said that chase thing damage by the isolation action that is white pollution done a long story in this outside a certain range by air quality change, dried present situation is really the environmental disruption by development and a damage phenomenon. If I am replaced in winker and I install a sensor light in the outlet by addition and use the electricity illumination that I installed for a tourist in the cave, it is expected that I can be available all the time that it is possible for electricity reduction more than the present and watches tourist passage plan private business Electric illumination in the cave for the environmental save in the cave because it is possible for

Numerical Study of Estimating the Arrival Time of UHF Signals for Partial Discharge Localization in a Power Transformer

  • Ha, Sang-Gyu;Cho, Jeahoon;Lee, Juneseok;Min, Byoung-Woon;Choi, Jaehoon;Jung, Kyung-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.94-100
    • /
    • 2018
  • Partial discharges (PDs) are electrical sparks that occur inside insulation between two conducting electrodes and can lead to the disastrous failure of insulation systems. To determine the location of a PD, a distributed array of UHF PD sensors is used to detect the electromagnetic (EM) signals emitted from the PD source, and the localization of the PD source can be estimated using the time difference of arrival (TDOA) between EM signals captured by the UHF PD sensor array. There are four popular methods to estimate the TDOA-the first peak method, the cross-correlation method, the energy criterion method, and the average time window threshold method. In this work, we numerically investigate the influence of noise on estimating the TDOA for the four different methods. Numerical results show that the energy criterion method is more robust against noise than other methods.

A Consideration on the Process Technology and Application of MEMS to prepare for upcoming MEMS-based technological paradigm (MEMS 기반의 새로운 기술적 패러다임에 대비한 공정 기술 분석 및 적용에 대한 고찰)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.7
    • /
    • pp.979-986
    • /
    • 2013
  • Recently, in the electric, electronic, robotic, and medical industries, a great attention has been paid to the development of MEMS-based smart devices with a compact size and highly intelligency. The MEMS technology is very effective in designing into a compact size and lightweight by combining into one the complex electrical, mechanical, chemical, and biological features which are required by smart devices, and at the same time, in bulk batch manufacturing. Therefore, this study, to prepare for upcoming new MEMS-based technological paradigm, analyzes MEMS processes and then considers its Applications.

Development of Optimal Control System for Lighting and HVAC(Heating, Ventilation, Air Conditioning) Using Energy Saving (에너지 절감용 조명 및 공조기기 최적제어 시스템 개발)

  • Jang, Woo-Sung;Song, Yeoung-Seok;Cho, Byung-Lok;Cho, Seok-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1029-1036
    • /
    • 2018
  • This paper is a study on the development of optimal control system for lighting and air conditioning equipment to save the energy in campus environment. In the case of controling system developed through this research, lighting and air conditioner are controlled by both information on the number of people entering and leaving the room through the motion sensor and image processing, and the information on temperature and humidity. In addition, energy saving is enabled by the results that are controlled through data integration monitoring and command execution functions according to the control signals.

Performance of SR Drive for Hydraulic Pump

  • Lee, Sang-Hun;Lee, Dong-Hee;An, Young-Joo;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.55-60
    • /
    • 2007
  • This paper proposes a hydraulic pump system that uses a variable speed SR drive and constant capacity pump. For the design of the SRM (Switched Reluctance Motor) and digital controller, base speed and rating torque are determined from the mechanical specifications of the hydraulic pump. In order to minimize the power consumption during the maintaining of preset oil-pressure, the pressure control system changes the maximum oil-pressure band and flow rate according to the motor speed. The DSP control system adjusts the oil-pressure and the speed of the SRM from the pressure sensor signal, due to conservation of power consumption by the hydraulic pump. A 2.2Kw, 12/8 pole SR motor and DSP based digital controller are designed and tested with experimental set-up. The test results indicate that the system has some good features such as high efficiency and rapid response characteristics.

Discrimination of Insulation Defects in a Gas Insulated Switchgear (GIS) by use of a Neural Network Based on a Chaos Analysis of Partial Discharge (CAPD)

  • Jung, Seoung-Yong;Ryu, Cheol-Hwi;Lim, Yun-Sok;Lee, Ja-Ho;Koo, Ja-Yoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.118-122
    • /
    • 2007
  • In this work, experimental investigation is carried out in order to design and fabricate the UHF sensor that is able to detect the partial discharges produced from 10 artificial defects introduced into the real scale 70kV GIS mock-up under high voltage within a well shielded room. As well, in order to verify the on-site applicability of our method, the newly proposed CAPD (chaos analysis of partial discharge) is combined with spectral analysis for identifying the nature of 10 artificial defects under investigation. The PD pattern recognition of each defect has been fulfilled by applying our ANN software. The result indicates that the recognition rate reaches up to 80% by the newly proposed method while the traditional PRPD analysis method allows us to obtain 41%. In consequence, it can be pointed out that the proposed method seems likely to be applicable to the real GIS at the site.

Application of an Optical Current Transformer For Measuring High Current

  • Kim, Yeong-Min;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.11
    • /
    • pp.9-16
    • /
    • 2010
  • This paper examines the temperature characteristics of an Optical CT (optical current transformer) using the Faraday effect for measuring high current in a super high voltage-power apparatus. It is performed as follows by the sensor for embodying Faraday effect. $\cdot$ A single-mode optical fiber capable of maintaining a polarization state is used. $\cdot$ A light source is applied at 1310[nm] to a Laser Diode. $\cdot$ The Linear of Faraday effect to a large current is evaluated and $\cdot$ A possible application using an Optical CT was shown. An Influence of Faraday effect to the surrounding temperature measured -40~50[$^{\circ}C$], and the characteristic of the current sensitivity was reported. An application using the results of the temperature compensation system was used in order to compensate for surrounding temperatures. A possibility of applying Optical CT for electric power apparatus was advanced further. We were able to confirm that this temperature calibration method can minimize the fluctuation of the output signal depending on the temperature conditions.

Organic Gas Response Characteristics for Horizontal Direction of Fatty Acid LB Ultra-thin Films (지방산 LB초박막의 수평방향에 대한 유기가스 반응특성)

  • Lee, Jun-Ho;Choe, Yong-Seong;Kim, Do-Gyun;Gwon, Yeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.379-384
    • /
    • 1999
  • Langmuir-Blodgett(LB) films which have high ordered orientation and ordering structure are fabricated by LB method which deposit the ultra-thin films of organic materials at a molecular level. The electrical characteristics of stearic acid LB ultra-thin films for the horizontal direction were investigated to develop the gas sensor using LB ultra-thin films. The optimal deposition condition to deposit the LB ultra-thin films was obtained from $\pi-A$ isotherms and the deposition status of stearic acid LB ultra-thin films was verified by the measurement of deposition ratio, UV-absorbance, and electrical properties for LB ultra-thin films. The conductivity of stearic acid LB ultra-thin films for horizontal direction was about $10_{-8}[S/cm]$. The activation energy for LB ultra-thin films with respect to variation of temperature was about 1.0[eV], which was correspond to semiconductor material. The response characteristics for organic gas were confirmed by measuring the response time, recovery time, and reproducibility of the LB ultra-thin to each organic gas. Also, the penetration and adsorption behavior of gas molecule were confirmed through the organic gas response characteristics of LB ultra-thin films with respect to temperature.

  • PDF

A study for development of Barrier coupler-type UHF sensor for Partial Discharge measurement in GIS(Gas Insulated Switchgear) (Gas Insulated Switchgear(GIS) 내부 부분방전 측정을 위한 Barrier coupler-type UHF센서 개발에 관한 연구)

  • Hwang, Chul-Min;Koo, Ja-Yoon;Lee, Young-Sang;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1897-1899
    • /
    • 2003
  • 본 논문에서는 Barrier coupler type UHF 센서의 현장적용 및 감도개선을 위해 외부잡음의 차폐방법과 광대역 안테나를 Barrier coupler type UHF센서에 적용시켜 센서의 성능을 개선시켰다. GIS 내부에서 발생하는 부분방전 신호를 검출하기 위하여 UHF대역(0.3${\sim}$3GHz)의 전자파 신호의 검출이 가능한 광대역 Rectangular 패치 안테나를 barrier coupler type UHF 센서에 적응 설계하였으며, Rectangular patch antenna를 배열(array) 했을 때의 특성들을 비교하였다. 이론 위해 상용화된 EM Simulator를 이용하여 센서의 방향성과 감도 특성을 검토하여 설계 및 제작하였다. 개발된 센서의 실제 특성을 분석하기 위해서 network analyzer로 센서의 특성을 분석하였고, 실규모의 GIS 챔버를 사용하여 다양한 결함에 대한 센서의 감도와 특성을 평가하였다. 본 연구의 결과로서 제작된 barrier coupler type UHF센서가 가스절연기기(GIS)의 부 부방전 신호를 검출할수 있음을 입증하였고, 광대역 외장형센서의 경우 patch antenna의 구조에 크게 상관하지 않음을 알 수 있었다. 향후에는 GIS 내장형 센서와 비교 연구론 통해 barrier coupler type 센서의 성능을 개선하고자 한다.

  • PDF

Bioimpedance Changes in Rats with CCl4-Induced Liver Fibrosis

  • Heo, Jeong;Jung, Dong-Keun
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.71-76
    • /
    • 2011
  • To characterize the relationship between the stage of hepatic fibrosis and bioimpedance, several electric parameters were estimated in rats with $CCl_4$-induced liver fibrosis. Thirty three Sprague-Dawley rats were intraperitoneally injected with a $CCl_4$-mineral oil mixture (1:1, 0.2 mL/100 g) twice a week for 8 weeks. The resistance(R), reactance(X), impedance(Z), and dissipation factor(D) between 1 kHz and 100 kHz were then evaluated in the livers of the rats under pentobarbital anesthesia using an HP4294A Impedance Analyzer. The rats were killed 2, 4, 6, and 8 weeks later, and their livers were classified in accordance with Ishak's scoring system. R, X, and Z changed in accordance with the progression of hepatic fibrosis and the changes were greater at lower frequencies than at higher frequencies. In comparison, the D spectrum was biphasic; D increased initially then decreased with increasing frequency. All of the parameters(R, X, Z, and D) changed in accordance with the stage of fibrosis in the livers, but D changed specifically with the progression of fibrosis. These results indicate that hepatic fibrosis may be evaluated by determining the changes in D.