• Title/Summary/Keyword: Electric safety

Search Result 1,828, Processing Time 0.036 seconds

Low price type inspection and monitoring system of lithium ion batteries for hybrid vessels (하이브리드 선박용 리튬 배터리의 저가형 감시시스템 구현)

  • Kwon, Hyuk-joo;Kim, Min-kwon;Lee, Sung-geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.28-33
    • /
    • 2016
  • Batteries are used for main power engine in the fields such as mobiles, electric vehicles and unmanned submarines, for starter and lamp driver in general automotive, for emergency electric source in ship. These days, lead-acid and the lithium ion batteries are increasingly used in the fields of the secondary battery, and the lead-acid battery has a low price and safety comparatively, The lithium ion battery has a high energy density, excellent output characteristics and long life, whereas it has the risk of explosion by reacting with moisture in the air. But Recently, due to the development of waterproof, fireproof, dustproof technology, lithium batteries are widely used, particularly, because their usages are getting wider enough to be used as a power source for hybrid ship and electric propulsion ship, it is necessary to manage more strictly. Hybrid ship has power supply units connected to the packets to produce more than 500kWh large power source, and therefore, A number of the communication modules and wires need to implement the wire inspection and monitor system(WIIMS) that allows monitoring server to transmit detecting voltage, current and temperature data, which is required for the management of the batteries. This paper implements a low price type wireless inspection and monitoring system(WILIMS) of the lithium ion battery for hybrid vessels using BLE wireless communication modules and power line modem( PLM), which have the advantages of low price, no electric lines compared to serial communication inspection systems(SCIS). There are state of charge(SOC), state of health(SOH) in inspection parts of batteries, and proposed system will be able to prevent safety accidents because it allows us to predict life time and make a preventive maintenance by checking them at regular intervals.

Analysis of Social Trends for Electric Scooters Using Dynamic Topic Modeling and Sentiment Analysis (동적 토픽 모델링과 감성 분석을 활용한 전동킥보드에 대한 사회적 동향 분석)

  • Kyoungok, Kim;Yerang, Shin
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.1
    • /
    • pp.19-30
    • /
    • 2023
  • An electric scooter(e-scooter), one popularized micro-mobility vehicle has shown rapidly increasing use in many cities. In South Korea, the use of e-scooters has greatly increased, as some companies have launched e-scooter sharing services in a few large cities, starting with Seoul in 2018. However, the use of e-scooters is still controversial because of issues such as parking and safety. Since the perception toward the means of transportation affects the mode choice, it is necessary to track the trends for electric scooters to make the use of e-scooters more active. Hence, this study aimed to analyze the trends related to e-scooters. For this purpose, we analyzed news articles related to e-scooters published from 2014 to 2020 using dynamic topic modeling to extract issues and sentiment analysis to investigate how the degree of positive and negative opinions in news articles had changed. As a result of topic modeling, it was possible to extract three different topics related to micro-mobility technologies, shared e-scooter services, and regulations for micro-mobility, and the proportion of the topic for regulations for micro-mobility increased as shared e-scooter services increased in recent years. In addition, the top positive words included quick, enjoyable, and easy, whereas the top negative words included threat, complaint, and ilegal, which implies that people satisfied with the convenience of e-scooter or e-scooter sharing services, but safety and parking issues should be addressed for micro-mobility services to become more active. In conclusion, this study was able to understand how issues and social trends related to e-scooters have changed, and to determine the issues that need to be addressed. Moreover, it is expected that the research framework using dynamic topic modeling and sentiment analysis will be helpful in determining social trends on various areas.

Plasma Polymerized Styrene for Gate Insulator Application to Pentacene-capacitor (유기박막트랜지스터 응용을 위해 플라즈마 중합된 Styrene 게이트 절연박막)

  • Hwang, M.H.;Son, Y.D.;Woo, I.S.;Basana, B.;Lim, J.S.;Shin, P.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.5
    • /
    • pp.327-332
    • /
    • 2011
  • Plasma polymerized styrene (ppS) thin films were prepared on ITO coated glass substrates for a MIM (metal-insulator-metal) structure with thermally evaporated Au thin film as metal contact. Also the ppS thin films were applied as organic insulator to a MIS (metal-insulatorsemiconductor) device with thermally evaporated pentacene thin film as organic semiconductor layer. After the I-V and C-V measurements with MIM and MIS structures, the ppS revealed relatively higher dielectric constant of k=3.7 than those of the conventional poly styrene and very low leakage current density of $1{\times}10^{-8}Acm^{-2}$ at electric field strength of $1MVcm^{-1}$. The MIS structure with the ppS dielectric layer showed negligible hysteresis in C-V characteristics. It would be therefore expected that the proposed ppS could be applied as a promising dielectric/insulator to organic thin film transistors, organic memory devices, and flexible organic electronic devices.

A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation (실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

A study on the Strategic Approach Method of the urban wastes for the Urban's Disaster Prevention and Safety Management (도시의 방재안전관리를 위한 도시페기물의 전략적 접근방법에 관한 연구)

  • Lee, Tae Shik;Cho, Won Cheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • This research has been shown the strategic disaster prevention and safety management's methodology that minimize the demage and loss from environmental disaster: it is made the renewable energy using the urban wastes causing the main environmental disaster, it minimize the generating cost from the environmental disaster, it gain the energy source for preparing the large-scale shutdown electricity, it gain the profit from the continuous electric power and heat energy's generating, it gain the renewal energy source from the old urban wastes' landfill, it give back the citizen the clean environment, the construction cost is able to be solved form the profit which the power plant is made the plasma gasification generation of the urban wastes, it create the new related jobs in the local government, it base to be invested the local industrial zone's commercialization due to the renewal energy power plant. Especially, in happen to the large-scale natural disaster's typhoon and earthquake, in the result generating the large-scale urban wastes, it is shown the prepared and robust model which contribute the preventing recovery of the local economy using the renewal energy of the urban wastes, and the strategic disaster prevention and safety management's method in the future city.

A Comparative Study on the Perceptions towards Personal Mobility Vehicle between Adults and Minors (개인형 이동수단에 관한 법·제도 개선방안 연구: 연령별 차이를 중심으로)

  • Choi, Nakhyeon;Kim, Junghwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.543-550
    • /
    • 2021
  • Recently, there has been an increase of accidents related to the rise in the use of Personal Mobility Vehicle (PMV). To solve this problem, the National Assembly announced an amendment that restricted the use of PMV to bicycle roads and to prohibited for people under 13 years old to use PMV, but there is no detailed information about travel speed and safety. In this study, a survey was conducted by dividing the group into minors and adults based on the age of obtaining a driver's license to find out the direction of improvement of laws and systems about PMV. Our results showed that adults considered PMV as more dangerous (Adults 5.50, Minors 4.94) and the suggested age for PMV use was lower from minors than adults (Adults 15.70, Minors 13.85). We found that proper travel speed on bicycle roads differed according to the presence of a driveway (Driveway 26.21 km/h, Non-Driveway 23.55 km/h) and minors had higher a travel speed than adults on all types of bicycle road. Also, Helmets for PMV were seen as the most important safety equipment on all types of bicycle road. and the importance of other safety equipment differed according to the presence of a driveway (Driveway Front-Lighting, Non-Driveway Car Horn). Through this study, It proposes that we have to make new regulations about the use of front lights and horns, as well as enforcement measures that differentiate the speed on each bicycle road type as a way to improve the laws and systems for PMV.

Lightning Protection System of Solar Power Generation Device (태양광발전장치의 낙뢰보호 시스템)

  • Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.157-162
    • /
    • 2023
  • Among the failures of photovoltaic power generation facilities, failures caused by surges account for 20% of the total failure rate, and energy emissions of tens to hundreds [A] during power generation and electrical damage to inverters and connection boards lead to electrical safety accidents. In particular, in the case of lightning, an abnormal voltage is induced in an electric circuit to destroy insulation, and the current flowing at this time causes a fire and acts as a factor that accelerates the deterioration of parts. Due to this action, the problem of electrical safety of solar power generation devices spreading from outside the city center to the inside of the city center such as houses, apartments, and government offices is emerging. Since lightning strikes cause both field-based and conducted electrical interference, this effect increases with increasing cable length or conductor loops. In addition, surge damages not only solar modules, inverters and monitoring devices, but also building facilities, which can eventually cause operational shutdown due to fire of the photovoltaic power generation system and consequent financial loss. Therefore, in this paper, a lightning protection system for solar power generation devices is studied for the purpose of reducing property damage and human casualties due to the increase in fire and electrical safety accidents caused by lightning strikes in photovoltaic power generation systems.

Prototype Fabrication and Performance Evaluation of Metal-oxide Nanoparticle Sensor for Detecting of Hazardous and Noxious Substances Diluted in Sea Water (해수 중 유해위험물질 검출을 위한 금속산화물 나노 입자 센서의 시작품 제작 및 성능 평가)

  • Sangsu An;Changhan Lee;Jaeha Noh;Youngji Cho;Jiho Chang;Sangtae Lee;Yongmyung Kim;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.23-29
    • /
    • 2022
  • To detect harmful chemical substances in seawater, we fabricated a prototype sensor and evaluated its performance. The prototype sensor consisted of a detector, housing, and driving circuit. We built the detector by printing an Indium-Tin-Oxide (ITO) nanoparticle film on a flexible substrate, and it had two detection parts for simultaneous detection of temperature and HNS concentration. The housing connected the detector and the driving circuit and was made of Teflon material to prevent chemical reactions that may affect sensor performance. The driving circuit supplied electric power, and display measured data using a bridge circuit and an Arduino board. We evaluated the sensor performances such as response (ΔR), the limit of detection (LOD), response time, and errors to confirm the specification.

A Study on the Impact of Forklift Institutional, Technical, and Educational Factors on a Disaster Reduction (지게차의 제도적, 기술적, 교육적 요인이 재해감소에 미치는 영향에 관한 연구)

  • Young Min Park;Jin Eog Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.770-778
    • /
    • 2023
  • Purpose: In order to reduce forklift industrial accidents, it is necessary to classify them into institutional, technical, and educational factors and conduct research on whether each factor affects disaster reduction. Method: Descriptive statistical analysis, validity analysis, reliability analysis, and multiple regression analysis were conducted using SPSS 18 program based on an offline questionnaire based on a 5-point Likert scale. Result: As a result of multiple regression analysis, it was found that institutional, technical, and educational factors, which are independent variables for disaster reduction, explain about 62.5% of the variance in disaster prevention, which is the dependent variable. The regression model verification was found to be statistically significant with F=118.775 and significance probability p<0.01. Conclusion: First, there is a need to prevent disasters by including electric forklifts weighing less than 3 tons in the inspection system. Second, there is a need to make it mandatory to install front and rear cameras and forklift line beams to prevent forklift collision disasters. Third, there is a need to conduct special training related to forklifts every year, and drivers and nearby workers need to be included in the special training for forklifts.

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.