• Title/Summary/Keyword: Electric railway system

Search Result 773, Processing Time 0.036 seconds

A Study on the Maintenance Period Optimization for the Urban Tansit Vehicles (도시철도차량 유지보수주기 최적화 연구)

  • Park, Kee-Jun;Chung, Jong-Duck;Suh, Myung-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.22-26
    • /
    • 2011
  • The urban transit vehicles has very complicated structures composed electric and mechanical parts and systems. Its system is important to insure operating stability pursuant to massive transfer. Also, its system takes a lot of maintenance cost than constructing cost due to its system which has longtime life cycle. Generally it is know that maintenance cost affect a lot on total cost because its life cycle cost takes a part more than 60~70%. For these reason, it is really important to reduce its maintenance cost through efficiently operation and maintenance management system construction.

  • PDF

A Study on the Daily Inspection of the Rolling-stocks (철도차량 일상검수 주기 및 방법에 관한 연구)

  • Yu, Yang-Ha;Lee, Nak-Young;Kim, Ho-Soon
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1642-1649
    • /
    • 2010
  • At present, KORAIL is in the middle of renovating. All steps exert great effort at cost reduction and a profit improvement. Especially to improve maintenance method and inspection period at the rolling-stock division lots of research is under progress. Daily inspection of rolling stocks is to operate the rolling stock normally. Daily inspection items are driving control device, coupling device, brake system, water system and air conditioning system, electrical system etc. Half of the maintenance manpower are inputted at daily inspection. Strengthens the quality and optimize the proportion of daily inspection are urgent problem. Daily inspection period extension aim is as follows. KTX from 3,500km to 5,000km, passenger car from 1st to 3,500km, new style electric locomotive from 2nd to 5,000km, the diesel locomotive is 2,800km from 1,200km. In this paper, the optimal daily inspection period and methods are considered including expected problem and counter measures.

  • PDF

The DB structure for Standard Criteria of Urban Transit Facilities (도시철도시설 표준화기준을 위한 DB구축방안 연구)

  • Lee, Woo-Dong;Kim, Jin-Ho;Han, Seok-Youn;Sin, Won-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.213-214
    • /
    • 2008
  • Since standardization project is composed of complicate system, such as vehicle, signal, electric power and railway, how to build management system of the project has influence on the success of the project for the first stage of the project. The computer system design tool supports to carry out requirement analysis, DB construction, and history and follow-up management efficiently. Therefore, the aim of this study is to investigate the method to optimize schema using computer system design tool.

  • PDF

Development of Inverter for Regenerative Power and Test Equipment (직류급전시스템 회생용 인버터의 시험설비 구축 및 특성시험)

  • Kim, Joo-Rak;Han, Moon-Seob;Kim, Yong-Ki;Kim, Jung-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.399-406
    • /
    • 2008
  • DC transit system has been adopted in the metropolitan area, Korea since 1974. EMU in this system always reiterates that acceleration and retardation. When EMU decelerates using electric breaking, regenerative power occurs. Regenerative power can be consumed in vicinity EMU on the same line or in resistor. If DC transit system has inverter for reusing regenerative power, Energy efficiency in DC transit system will be increased. This paper present the developed inverter for regenerative power and its test equipment. Test result of developed inverter is presented.

  • PDF

Fault diagnosis of induction motor using principal component analysis (주성분 분석기법을 통한 유도전동기 고장진단)

  • Byun Yeun-Sub;Lee Byung-Song;Bae Chang-Han;Wang Jong-Bae
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.529-534
    • /
    • 2003
  • Within industry induction motors have a broad application area to drive pumps, fans, elevators and electric trains. Sudden failures of such machines can cause the heavy economical losses and the deterioration of system reliability. Based on the reliability and cost competitiveness of driving system (motors), the faults detection and the diagnosis of system are considered very important factors. In order to perform the faults detection and diagnosis of motors, the vibration monitoring method and motor current signature analysis (MCSA) method are emphasized. In this paper, MCSA method are used for induction motor fault diagnosis. This method analyzes the motor's supply current, since this diagnoses faults of the motor. The diagnostic algorithm is based on the principal component analysis(PCA), and the diagnosis system is programmed by using LabVIEW and MATLAB.

  • PDF

A Study on Protection system to the Load Characteristics on the AC Feeder System (부하 특성에 따른 교류 급전시스템에서의 보호방식 연구)

  • Jung Ho-Sung;Han Moon-Seob;Lee Chang-Mu;Kim joorak
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1370-1372
    • /
    • 2004
  • At present. distance relay and ${\Delta}I$ current increment relay are used as primary and secondary protection in the AC feeder system. However. electric railway vehicles according to power electronic's development had developed resistance control, thyristor phase control and PWM control system. and operation of train is increasing in a feeder section. Therefore this paper analyzes the load characteristics and situation of relay's maloperation caused by load current increase, harmonics, regenerative braking current and operation of the different vehicles in same feeder section. Based on this analysis. this paper proposes consideration items for relay correction and advanced adaptive relay that can change operation area according to load current.

  • PDF

Implementation of FPGA-Based Real-Time data acquisition system for overhead contact wire (FPGA를 이용한 전차선로 실시간 계측시스템 구현)

  • Na, Hae-Kyung;Park, Young;Cho, Yong-Hyeon;Jung, Ho-Sung;Park, Hyun-Jun;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.531-532
    • /
    • 2006
  • This paper presents the implementation of Real-time data acquisition system for dynamic characteristics of overhead contact wire in electric railway. The reconfigurable field-programmable gate array (FPGA) and LabVIEW graphical development tools have been used to Real-time monitoring system. The results from a field test show that the proposed technique and developed system can be practically applied to measure the assessment quantity or quantities on overhead contact lines for the online real-time process monitoring.

  • PDF

A Result of the Field Test for Regenerative Inverter (직류급전시스템의 에너지회생장치 적용을 위한 실계통 부설 시험)

  • Kim, Joo-Rak;Han, Moon-Seob;Jang, Dong-Uk;Kim, Jung-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.286-293
    • /
    • 2008
  • DC transit system has been adopted in the metropolitan area, Korea since 1974. EMU in this system always reiterates that acceleration and retardation. When EMU decelerates using electric breaking, regenerative power occurs. Regenerative power can be consumed in vicinity EMC on the same line or in resistor. If DC transit system has inverter for reusing regenerative power, Energy efficiency in DC transit system will be increased. This paper present the developed inverter for regenerative power and its field test. Test result of developed inverter is presented.

  • PDF

A Study on the Development of Capacitor Exchange Type GDU of Propulsion Control Device of Electric Railway Vehicle Capable of Life Diagnosis (수명진단이 가능한 전기철도차량 추진제어장치의 커패시터 교환 형 GDU 개발에 관한 연구)

  • Kim, Sung Joon;Chae, Eun Kyung;Kang, Jeong Won
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.475-484
    • /
    • 2018
  • The propulsion control device of an electric railway vehicle is a key main component corresponding to an engine of an automobile, and a device for controlling this is a device called a GDU (Gate Drive Unit). Also, when the frequency of failure of the propulsion control system was analyzed, the nonconformity ratio of GDU was the highest. GDU was not able to access core technologies due to the introduction of foreign products, and there were general problems with overall maintenance activities due to discontinuation of GDU of the manufacturer. The GDU has reached the end of its life with 23 to 14 years of long-term use.In order to solve these problems, this study was designed to identify the proper life span by analyzing compatible GDU's acquisition and failure, and to improve the existing system of maintenance focusing on health inspection. Maintenance of the components with a short life span compared to the entire service life is essential. Most foreign parts introduced at the beginning of the construction are not replaced due to technical problems or long-term operation. However, due to the characteristics of railway vehicles with a long life span of more than 25 years, it is necessary to maintain them for a long period of time. The study should be more concrete and empirical. The replacement type GDU of capacitors was able to easily measure the life of the capacitance by removing the capacitor modules, measure the life span of each unit test, and accurately perform preventive maintenance of the capacitor.

Algorithm Development for Improving Output Characteristics of Thyristor Dual Converter with AC Input Voltage Variation (교류 입력 전압 변동에 따른 사이리스터 듀얼 컨버터의 출력 특성 개선을 위한 알고리즘 개발)

  • Kim, Sung-An;Han, Sung-Woo;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1437-1443
    • /
    • 2017
  • Electric energy is consumed or regenerated according to an operation of electric rail cars in urban railway power substations. A thyristor dual converter system is used to deal with the electric energy. Since the AC input voltage of power substations is $22.9kV{\pm}10%$, the magnitude of the AC voltage fluctuates according to load conditions, so the secondary side voltage of the DDY transformer also fluctuates. In the thyristor dual converter, the response characteristics of the DC output voltage and the DC output current are changed based on an initial firing angle in the cross mode conversion between the forward mode and the reverse mode. Therefore, this paper proposes the initial firing angle tracking algorithm considering fluctuation of the AC input voltage. The effectiveness of the proposed algorithm is verified by a simulation compared with the conventional algorithm.