• 제목/요약/키워드: Electric probe

검색결과 231건 처리시간 0.025초

페라이트 형상에 따른 부분방전 진단용 EM Probe의 특성 (Characteristics of the EM Probe with Differential Shapes for Partial Discharge Diagnosis)

  • 양상현;이세일;이용성;박노준;김희동;박형준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.398-399
    • /
    • 2009
  • 본 논문에서는 XLPE 전력케이블 접속부의 부분방전을 측정하기 위한 Ferrite 형상에 따른 EM Probe를 설계하였다. 부분방전 펄스의 검출대역를 넓이기 위해 투자율이 2400인 페라이트코어를 사용하여 센서를 제작하였고 형상에 따른 특성을 비교하기위하여 실린더형 Ferrite와 말굽형 Ferrite를 적용하였다. 또한 부분방전 검출능력을 확인하기 위해 상용 HFCT센서의 비교 실험을 통하여 위상특성과 주파수 특성을 분석하였다.

  • PDF

프루브 팁용 BeCu 박막의 피로성질 연구 (A Study On Fatigue Properties Of BeCu Thin Film For Probe Tip)

  • 신명수;박준협;서정윤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.256-259
    • /
    • 2008
  • An micro-probe tip must be manufactured using thin film to evaluate integrity of the semiconductor with narrow distance between pads. In this study, fatigue tests were performed for BeCu thin film which is used in micro-probe tip of semiconductor test machine. The thin film was manufactured by electro plating process, and the specimens were fabricated by wire-cut electric discharge method to make hour glass type specimen of $5000{\mu}m$ width, $29200{\mu}m$ length and $30{\mu}m$ thickness. The fatigue test of load control with 10Hz frequency was performed, in ambient environment. The fatigue cycles were tension-tension with mean stress, at stress ratio, R=0.1.

  • PDF

부분방전 전계 측정용 $LiNbO_3$ 프루브 센서 제작 (A development of $LiNbO_3$ probe sensor for detecting partial discharge)

  • 강원종;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1041-1043
    • /
    • 1999
  • In this work, a possible new PD detection technique, based on the electro-optic effect, has been proposed. A proto-type probe sensor for detection partial discharge is made by $LiNbO_3$ Pockels cell, diachroic sheet polarizer and right-angle prism. The Mach-Zehnder interferometer system is proposed by using this sensor and this system is applied to detecting high electric field. we show the characteristic of the proto-type probe sensor and the design of a proposed probe type sensor.

  • PDF

ECR Reactor 내의 Langmuir Probe 시뮬레이션 (Simulation of a Langmuir Probe in an ECR Reactor)

  • 김훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1609-1611
    • /
    • 1994
  • In ECR and helicon reactors for plasma processing, a high density plasma is generated in a source region which is connected to a diffusion region where the processing takes place. Large density and potential gradients can develop at the orifice of the source which drive ion currents into the diffusion region. The average ion velocity may become the order of the sound velocity. Measurements of the ion saturation current to a Langmuir probe are used as a standard method of determining the plasma density in laboratory discharges. However, the analysis becomes difficult in a steaming plasma. We have used the HAMLET plasma simulator to simulate the ion flow to a large langmuir probe in an ECR plasma. The collection surface was aligned with the Held upstream, normal to the field, and downstream. ion trajectories through the electric and magnetic fields were calculated including ion-neutral collisions. We examines the ratio of ion current density to plasma density as a function of magnetic field and pressure.

  • PDF

치수혈류 측정을 위한 광 프로브 개발 (Development of an Optical Probe for Measuring Blood Flow in Dental Pulp)

  • 장경환;최준열;구정모;권민경;김덕원
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1204-1209
    • /
    • 2012
  • To diagnose dental pulp vitality, electric pulp tester has been widely used, which is a method to test condition of nerve. However, especially in the case of patients with trauma, nerve desensitization could temporarily occur even though nerve might be recovered by blood flow within the pulp later, which implies that blood flow in dental pulp is also an important factor for diagnosing vitality. This paper described the development of a probe that relatively measured blood flow in dental pulp using photoplethysmography (PPG). The probe emits four different wavelength light sources including three visible and an infrared light. We tested which light source detect sensitively the blood flow in dental pulp. As a result, green light had the largest peak to peak voltage and the power spectrum among different wavelengths.

Ar 가스 압력과 RF 전력에 따른 유도결합형 플라즈마의 전기적 및 광학적 특성 (Electrical and Optical Characteristics of Inductively Coupled Plasma by Ar Gas Pressure and Rf Power)

  • 최용성;허인성;이영환;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제17권5호
    • /
    • pp.560-566
    • /
    • 2004
  • In this paper, the electrical and emission properties of electrodeless fluorescent lamp were discussed using the inductively coupled plasma (ICP) with the variation of argon gas pressure and RF power. The RF output was applied to the antenna in the range of 5∼50 W at 13.56 MHz. The internal plasma voltage of the chamber and the probe current were measured while varying the supply voltage to the Langmuir probe in the range of -100V∼+100V. When the pressure of argon gas was increased, electric current was decreased. There was a significant electric current increase from 10 to 30 W. Also, when the RF power was increased, electron density was increased. Also, the emission spectrum, Ar- I lins, luminance were investigated. At this time, the input parameter for ICP RF plasma, Ar gas pressure and RF power were applied in the range of 10∼60 mTorr, 10∼300 W, respectively. This implies that this method can be used to find an optimal RF power for efficient light illumination in an electrodeless fluorescent lamp.

Direct Fabrication of the Scanning Probe Tip with Multi­Walled Carbon Nanotubes Using Dielectrophoresis

  • Lee Hyung-Woo;Han Chang-Soo;Lee Eung-Sug;Chul Youm;Kim Jae Ho;Kim Soo-Hyun;Kwak Yoon-Keun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권2호
    • /
    • pp.50-54
    • /
    • 2005
  • We report a simple, low cost, and reliable method for assembling a multi-walled nanotube (MWNT) to the end of a metal coated scanning probe microscopy (SPM) tip. By dropping the MWNT solution and applying an electric field between an SPM tip and an electrode, MWNTs which were dispersed into a dielectric solution were directly assembled onto the apex of the SPM tip due to the attraction by the dielectrophoretic force. The effective measurement of a MWNT -attached SPM tip was demonstrated by direct comparison with AFM images of a standard sample with a bare AFM tip.

디젤발전 자켓냉각시스템 열성능 향상 연구 (Performance Research of a Jacket Cooling Water System in a Diesel Electric Generation)

  • 이재근;문전수;윤석원;박필양
    • 한국수소및신에너지학회논문집
    • /
    • 제20권6호
    • /
    • pp.534-539
    • /
    • 2009
  • One of the most efficient techniques improving the heat transfer performance of a diesel electric generation is a corrosion control in jacket cooling water system. The environmental parameters most affecting corrosion are dissolved salt concentration, temperature, and pH of cooling water. No corrosion occurs in carbon steel probe at pH 11 in normal operating condition of diesel electric generation cooling water. pH control agent in this study is trisodium phosphate. pH control appears to be the most convenient way to enhance the thermal performance of a diesel electric generation.

$8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발 (Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe)

  • 남민우;이희종;김철기
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.184-190
    • /
    • 2008
  • 원전 증기발생기 전열관의 건전성을 평가하기 위해서 여러 가지 와전류검사 기법이 적용되고 있다. 이와 같은 와전류검사 기법중에서 보빈탐촉자 기법은 전열관에 발생할 수 있는 축방향균열, 마모 검사에 적용하고 있으며, MRPC 기법은 튜브시트 상단 및 곡관부위 균열의 정밀검사에 적용된다. 원전 증기발생기 전열관의 설치공정 혹은 운전중에 전열관에 덴트(dent, 혹은 ding) 및 벌지(bulge)가 형성될 수 있으며, 와전류검사에서 이러한 지시는 결함으로 간주하지 않기 때문에 일정 크기 이상의 지시만 검사보고서에 기록하여 관리하고 있다. 이러한 지시는 보빈탐촉자 기법으로 용이하게 검출이 가능하고 보빈단면형상검사에 의해 대략적인 크기의 측정이 가능하지만, 정확한 크기 및 형상은 알 수는 없으므로 본 연구에서는 단면형상검사의 정확도를 증가시키기 위해 $8{\times}1$ 다중코일 탐촉자를 설계 개발하여 그 정확도를 평가하였다. 한편, OPR-1000형 증기발생기 전열관의 튜브시트 확관 천이영역에 형성된 덴트부위에 균열성 결함이 발생할 가능성이 높기 때문에 일부 발전소에서는 예방차원의 슬리빙을 수행하고 있다 이와 같은 슬리빙 대상 전열관 선정시 본 검사기법을 활용하면 유용할 것으로 판단된다.

prototype 패치 안테나를 이용한 고압 회전기의 부분방전 측정 연구 (PD Diagnosis on High Voltage Rotating by Using New Prototype Patch Antenna Sensor)

  • 키아우소 륀;신동훈;임광진;공태식;김회동;박노준;박대회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.169-171
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the HV Rotating Machine with the new prototype patch antenna sensor. In this study, we design new type of patch antenna based on microstrip technology and make many experiments of elaine testing compare with the existing HFCT and EM probe on stator winding of HV generator in the laboratory. This paper will mention comparison of experimental results based on the three kinds of sensors.

  • PDF