• 제목/요약/키워드: Electric power loss

검색결과 596건 처리시간 0.025초

고효율 절연형 DC-DC 초퍼의 특성해석 (Performance Analysis of High Efficiency DC-DC Chopper added in Electric Isolation)

  • 곽동걸;이봉섭;김춘삼;정도영;김수광
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.115-117
    • /
    • 2007
  • This paper is analyzed for DC-DC chopper performance of high efficiency added in electric isolation. The general converters of high efficiency are made that the power loss of the used switching devices is minimized. To achieve high efficiency system, the proposed chopper is constructed by using a partial resonant circuit. The control switches using in the chopper are operated with soft switching for a partial resonant method. The control switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the efficiency of chopper is high. And the proposed chopper is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed chopper is adopted with system development of high efficiency. The soft switching operation and the system efficiency of the proposed chopper is verified by digital simulation and experimental results.

  • PDF

풀형 고속증식로의 과도 현상을 모사하는 Fast Running System Code개발 (Fast Running System Code Development to Simulate Transient Behavior of Pool-Type LMFBRs)

  • Youg Bum Lee;Soon Heung Chang;Mann Cho
    • Nuclear Engineering and Technology
    • /
    • 제17권1호
    • /
    • pp.16-24
    • /
    • 1985
  • 풀형 고속증식로에서의 과도 현상을 모사할 수 있는 전산 모델이 개발되었다. 이 전산 모델 SIM-FARP는 어떠한 펌프로의 전원 상실사고나 완전한 강제냉각 상실사고, 그리고 자연순환 과정 등을 모사할 수 있는 Fast Running Computer Code이다. 이에 따라 8개의 지배방정식이 유도되었으며, 이8개의 미분 방정식을 풀기 위해 Runge-Kutta의 수치해석방법이 사용되었다. 개발된 전산 프로그램은 두 가지 예제에 적용되었는데 이는 Super-Phenix-I에서의 펌프에의 전원상실사고 및 원자로가 정지되지 않는 상태에서의 외부전원 상실사고이다.

  • PDF

플라이휠 에너지 저장 시스템용 양측식 영구자석 동기 전동/발전기의 착자 형태에 따른 특성 비교 (Characteristic comparison of double-side PMSM/G according to magnetization pattern for flywheel energy storage system)

  • 장석명;최지환;유대준;성소영;한상철;이정필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1021-1022
    • /
    • 2011
  • This paper presents the double side PM synchronous motor/generator for core loss reduction in flywheel energy storage system. The use of double PM rotor causes the elimination of core loss in no-load state of machine. Because flywheel rotational speed is reduced by core loss, double PM rotor is very effective in flywheel system. This paper suggests two types of double side PM rotor, Halbach magnetized array and parallel magnetized array. And characteristic comparison according to thickness of rotor back core is performed.

  • PDF

플라즈마 중합법에 의한 헥사메틸디실록산 박막의 전기적 특성 (Electrical Properties of Plasma Polymerized Hexamethyldisiloxane Thin Film)

  • 이상희;이덕출
    • 한국전기전자재료학회논문지
    • /
    • 제14권1호
    • /
    • pp.43-47
    • /
    • 2001
  • Plasma polymerized hexamethyldisiloxane thin film was fabricated by employing an inter-electrode capacitively coupled type apparatus under the following conditions : carrier gas flow rate of 11 sccm, reaction pressure of 0.1 torr, discharge frequency of 13.56 MHz and discharge power of 30∼90 W. Polymerization rate of thin film fabricated at the discharge power of 90W is 32.5nm/min. Relative dielectric constant and dielectric loss tangent of thin film shows 3.2∼3.8 and 2.6x10$\^$-3/∼4.51x10$\^$-3/ respectively in the frequency range of 1 kHz∼1 MHz. As the annealing temperature is increased, the relative dielectric constant gradually decreases while the dielectric loss tangent increases. The current density increase gradually with increasing annealing temperature and electric field. The electric conduction of the heaxamethyldisiloxane thin film shows Schottky effect.

  • PDF

3kW 계통연계형 태양광발전시스템의 운전특성 (The Operating Characteristics of 3kW Utility Interconnected Photovoltaic System)

  • 김형석;박정민;나종덕;백형래;조금배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.201-204
    • /
    • 2004
  • Consider the optimal design for PV system, it is apply to 3kW interconnected electric power PV system, that is a point of reference for 3kW PV the spread residential section system. Through the driving various practical system, we look into that for efficiency of generation and stability of interconnected system. Using obtained data acquisition, It can be suggest that installation and management for system parameter to optimal design maximum generation electric power. PV system have some losses that are variation radiation, shadow, change temperature, unbalanced grid connection, serial circuit loss, MPP deference loss, PCS loss and so forth. Using obtained various performance characteristic result, we can make database in the future, through the this study, we can get the reliance and have regard to spread PV system.

  • PDF

고조파 전류가 변압기 진동에 미치는 영향에 관한 연구 (The Study of the Harmonic Currents Effects on the Transformer Vibration)

  • 김수열;김연환;김장목;임익헌;이현
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.106-111
    • /
    • 2000
  • EP(Electrostatic Precipitator) has been used to keep the natural environment from fly-ash in the industrial fields and operated in intermittent PEC(Pulse Energized Control) mode to improve dust-collecting efficiency. Intermittent PEC mode induces low-frequency harmonic currents into power system, therefore EP transformer vibrates. This continuous transformer vibration developes transformer abnormal audio-noise and if it is too much or operates in the region of natural frequency, transformer will be damaged in the end. EP interruption caused by transformer damage results in power generation stopped, power quality down and economic loss. Therefore, this paper explains harmonic currents and transformer vibration-core vibration, winding vibration, and proposes the measures of suppressing the vibration with EP operated in intermittent PEC mode. And this results is proposed to be used for future EP transformer design or EP control method to operate EP-concerned equipment safely keeping from system faults caused by transformer vibration.

  • PDF

부반응 저감 조성 K계 건식 CO2 흡수제 특성평가 (Characterization of Potassium Based Dry CO2 Sorbents Developed for the Reduction of Side Reactions)

  • 장영신;김의식;윤양노;백점인
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권4호
    • /
    • pp.337-341
    • /
    • 2019
  • In this study, the effects of two materials, active alumina and CaO based inorganic binder, which cause the side reaction on the K2CO3-based solid CO2 sorbents was investigated. K2CO3-based solid sorbents called KAM series was prepared by spray drying method and then measured its physical properties and CO2 sorption capacity. Among the KAM series sorbents, KAM(0.5) maintained high CO2 sorption capacity of 7.6 wt% after 3 cycle of sorption/regeneration reaction and showed very low attrition loss as low as 3.1 % which was measured by ASTM D5757-95.

UPS에서 전원 절체시 과도특성에 관한 연구 (A study of transient characteristics during the transfer of the source of electric power in UPS)

  • 이영수;이간운;차재만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.88-90
    • /
    • 2005
  • There are a lot of troubles during the transfer of the source of electric power in UPS (uninterruptible power supply system) which is indispensable to the industrial equipments. They cause blackout accidents, resulting in a great economic loss. After measuring and analyzing the transient phenomena happening during the transfer, this paper presents the solution of the troubles. The solution can be used as a basic material for maintenance and it can minimize the troubles occurring in UPS and enhance the reliability of it.

  • PDF

손실배분계수를 이용한 송전선로 유효전력 손실의 배분법 (A Method to Allocate Real Power Losses of Transmission Lines using Loss Distribution factors)

  • 노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1259-1261
    • /
    • 1999
  • The paper proposes a simple method to calculate the portion of real power losses allocated to individual loads. The method is implemented by loss distribution factors, and analyses the share of loads in transmission line losses. Effectiveness of the algorithm is verified by a computer simulation. The results can be used to compute the cost of ancillary services under deregulated environment in electric power industries.

  • PDF

A Study on Thimble Plug Removal for PWR Plants

  • Song, Dong-Soo;Lee, Chang-Sup;Lee, Jae-Yong;Jun, Hwang-Yong
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.611-616
    • /
    • 1997
  • The thermal-hydraulic effects of removing the RCC guide thimble plugs are evaluated for 8 Westinghouse type PWR plants in Korea as a part of feasibility study: core outlet loss coefficient, thimble bypass flow, and best estimate flow. It is resulted that the best estimate thimble bypass flow increases about by 2% and the best estimate flow increases approximately by 1.2%. The resulting DNBR penalties can be covered with the current DNBR margin. Accident analyses are also investigated that the dropped rod transient is shown to be limiting and relatively sensitive to bypass flow variation.

  • PDF