• Title/Summary/Keyword: Electric power facilities

Search Result 514, Processing Time 0.029 seconds

An Investigation on the Air Pollution for Distribution Facilities In Metropolitan Area (22.9kV-Y 배전설비에 부착된 대도시 대기오염성분에 대한 조사연구)

  • Kim, Dong-Myung;Yoon, Tae-Sang;Park, Sang-Man;Yi, Sue-Muk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1548-1550
    • /
    • 2000
  • The effect of air pollution on the distribution facilities was investigated. In order to evaluate the pollution level in the metropolitan area, contaminated specimens were analyzed with various technique such as ICP-AES, EA, and so on. The contaminants on the surface of the distribution line or insulators were combined with approximately 10 percent of organic and 90 percent of inorganic materials. We found out that the electric facilities were affected by the contaminants on the surface of the facilities.

  • PDF

The Implementation of IED for Diagnosis of Electric Devices (전력 설비 진단을 위한 IED 의 구현)

  • Oh, Jae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1110-1111
    • /
    • 2007
  • These days, the concerns about maintenance and repair of electric facilities for stable and reliable electric power supply are increasing day by day. Because, we can have enormous damages economically and socially from a problem of the facilities, no matter how it is a small one. Especially, electric facilities in our country had been built abruptly from 40 years ago, so it can be thought that here are great amount of old facilities that must be repaired or replaced with new one, and the number would be increased time by time. On this situation, many researchers are studying the efficient and reliable method of maintenance for electric facilities and the results are applied on the facilities gradually by growing interests of operators and managers of the facilities. In this paper, the IED(Intelligent Electronic Devices) for Diagnosis system of electric machines are described. It takes analog data from a sensing device and operates digital processor to get a optimum digital data for diagnosis system. Now, this device is applied on several high voltage substations to diagnose and maintain GIS. Brief schematic of total diagnosis system and the construction of the IED are included in this paper.

  • PDF

A Study on the Information Exchange Technique among Electric Power Facilities and Monitoring Systems (전력 설비 감시 시스템들 간의 정보 교환 기법에 관한 연구)

  • Hong, Chang-Ho;Park, Chan-Eom;Lee, Seung-Chul;Hoon, Un-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.453-456
    • /
    • 2006
  • In this paper, we introduce the design and implementation of Information exchange technique among power system facilities and/or their monitoring systems based on Universal Description, Discovery and Integration Service and Simple Object Access Protocol. The rapid progresses in high speed network, 4G web language S/W and embedded H/W enabled faster and easier communications among electric power systems monitoring facilities. However, each facility or system has its own specific protocol like RS-232 and RS-486, which somewhat limits the capability of flexible information exchange among thor In this paper, we try to demonstrate the potential of utilizing the SOAP and UDDI services in exchanging the metadata and possibly high abstraction level informations among electric power facilities and/or their monitoring systems.

  • PDF

A Study on the Failure Effect Analysis of Overhead Transformer Considering Weather (기상요인에 따른 가공변압기의 고장영향 분석에 관한 연구)

  • Oh, Do-Eun;Jang, Seung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.857-862
    • /
    • 2017
  • The management of the electric power facilities became important in accordance with the industrial development and electric power facilities were influenced by weather. Even if the same kind of electric power facilities is estimated for extracting the time-varying failure rate, the failure rate could be different depending on external effect such as climate. This research will show the data mining modeling of the weather-related outage and influence of weather on the electric power facility with recent data.

A study on the improvement of the thermal expansion formula of the insulating oil in electric facilities (전력설비 절연유 열팽창 계산식 개선에 관한 연구)

  • Rim, Seong-Hwang;Moon, Bong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.153-156
    • /
    • 2001
  • The transformer and the OF cable are cooled and insulated by insulating oils in their body. The insulating oil expands or contracts with the heat transfer according to the operating conditions of the electric facilities. So we install the $N_2$ gas tank connected with the insulating oil system to overcome the change. The change of the insulating oil volume for the operation temperature range must be calculated to decide the $N_2$ gas volume and to set the alarm point for safe operation. It is known that this change is proportional to the temperature change and to the insulating oil volume if the temperature change is small enough.[1][11] However this proportional formula has been accepted generally in the design of electric facilities for wide operation temperature range such as $40^{\circ}C{\sim}125^{\circ}C$. Hence, it makes large errors in calculation which car result in serious damage against safe operation of the electric facilities. This paper presents a improved method of calculating the accurate change of the insulating oil volume to insure the safe operation of electric facilities.

  • PDF

Network Design for Construction of Remote Diagnosis System for Power Facilities of Electric Railway (전기철도 전력시설 진단용 원격진단시스템 구축을 위한 네트워크 설계)

  • Kim, Jae-Moon;Kim, Yang-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.432-436
    • /
    • 2009
  • This paper is described that advanced study on network design of remote diagnosis system for power facilities of electric railway. In the field, it is very difficult for worker to diagnosis power facilities including catenary because workers should be maintenance on AC power supply. Therefore, to properly design on remote diagnosis system, we have searched the inside and outside of the country-related technology trends. Also we confirmed that required technologies to design interface technology required for the development of sensor devices and the USN network was designed in accordance with required skills. Throughout variety of requirements, we have development iRFS based ZA sensors and iRFM to receive data of sensor. Also CC2420 is applied as single-chip which used 2.4GHz IEEE802.15.4 compliant RF tranciver designed for low-power and low-voltage wireless applications for ZigBee communication.

Development of the equipment for detecting the poor power facilities by receiving electric noises (전자파 잡음을 이용한 전기설비 불량 검출장치 개발)

  • 이복규;강성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1356-1359
    • /
    • 1997
  • There are various methods to detect the faulty electric facilities(esp, insulator) indirectly on power distribution lines at a certain distance apart. This paper describes the proto type equipment to detect a faulty insulator by receiving a electric discharge noises, which are generated with a periodicity of 120Hz.

  • PDF

Conceptual Design and Operation Results for SF6 Decomposition and Pollution Control System (SF6 분해 및 무해화 시스템의 개념 설계 및 운영 결과)

  • Joongwon, Lee;Miyeong, Kim;Jiho, Ahn;Younghwan, Byun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.111-118
    • /
    • 2022
  • SF6 is used as an insulating gas because of its excellent electrical insulation properties, non-toxicity, and non-inflammability. On the other hand, the global warming potential of SF6 is 23,900 times higher than that of CO2. The Korea electric power cooperation (KEPCO) is responsible for 80% of the domestic SF6 usage, and approximately 6,000 tons are currently charged in electrical and power facilities. KEPCO will gradually replace the insulating gas with SF6-free gas from 2023. SF6 decomposition facilities are required because more than 60 tons of SF6 will need to be disposed of annually from existing equipment. This study developed a novel decomposition and pollution control system that can process 60 tons of SF6 per year. This facility can decompose more than 97.7% of SF6, with the emissions of hazardous and toxic materials below the legal limit.

Report on VE & LCC (Value Engineering, Life Cycle Cost) Technics Introduction about the Electric Power Equipment (전력시설물에 대한 VE 와 LCC기법 도입에 관한 연구)

  • 김상직;장우진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.81-86
    • /
    • 2003
  • Recently the introduction of VE & LCC techniques for large size electric power facilities be achieved in various kinds form, of and tends to evaluate to the beginning investment cost when think about cost of electric power facilities usually, but must consider all life cycle cost (maintenance cost, repair cost, improvement cost, operation cost, electric power cost etc.). This treatise applies design techniques that consider copper loss related by voltage drop at power supply of long distance in trunk design and all life cycle cost techniques

  • PDF