• Title/Summary/Keyword: Electric power equipments

Search Result 218, Processing Time 0.023 seconds

Novel islanding detection method for grid connected PV system (계통연계형 태양광발전시스템의 새로운 단독운전 검출기법)

  • Jung, Young-Seok;So, Jung-Hun;Yu, Byung-Gyu;Yu, Gwon-Jong;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1705-1707
    • /
    • 2005
  • This paper proposes a novel active frequency drift(AFD) method for the islanding prevention of grid-connected photovoltaic inverter. To detect the islanding phenomenon of grid-connected photovoltaic(PV) inverters concerning about the safety hazards and the damage to other electric equipments, many kinds of anti-islanding methods have been presented. Among them, AFD method using chopping fraction(cf) enables the islanding detection to drift up(or down) the frequency of the voltage during the islanding situation. However, the performance of the conventional AFD methods, which have a certain value of cf only, is inefficient and difficult to design the appropriate cf value analytically to meet the limit of harmonics. In this paper, the periodic chopping fraction based on an AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 929-2000 with the power quality and islanding detection time. To verify the validation of the proposed method, the islanding test results are presented. It is confirmed that the proposed method has not only less harmonic distortion but also good performance of islanding detection compare with the conventional AFD method.

  • PDF

The study on advertisement of dental devices & instrument during Japanese colonized period (광고를 통해 본 일제강점기 치과 장비 및 기구 광고에 관한 연구)

  • Shin, Jai-Eui
    • The Journal of the Korean dental association
    • /
    • v.48 no.12
    • /
    • pp.893-918
    • /
    • 2010
  • This article is purposed of reviewing the development history of Japanese dental devices and instrument, and their related advertisement activities during the Japanese colonized period in Korea in early 20th century. Japanese dental devices and instrument were redesigned to accommodate their ergonomic shape above the simple imitation, and it implies the excessive desires brought them frustrations. The tragic earthquake on Sep. l, 1923, medical insurance law enforcement on Jan. 1, 1927, celebration of "Cavity prevention Day" started on Jun. 4, 1928, and the attack of Manchuria and China by Japan after 1931, all of these historical incidents become the preliminary requirement for the development of dental devices. On Nov. 1, 1937, Japanese government started to control dental materials, driving the campaigns for excluding foreign products and encourging the use of local products. In 1939, Nakajima dental manufacturers used this political and social atmosphere on their advertisement as saying "Our Nakajima's products have no compromise with the short raw materials, but only commitment to our quality". Since after 1940, the price and supply have been strongly under control, and the control group was appeared to manage all of supply and distribution of raw materials, regular price system, and specifications. At last, the Japanese national power were devastated in its production and distribution capacities, and get to the frustrated period. The main advertised dental devices and instruments in Korea during the Japanese colonized period were 1) dental chair, unit and cabinet, 2) dental x-ray, 3) compressors, 4) dental needles, 5) small instrument and carryon medical(emergency) kit, 6) oral hygiene and pyorrhea alveolaris, infrared rays, sunlight lamp, ultrashort wave treatment devices, 7)crown former, electric furnace, casting machine, articulator, electric lathe, and laboratory equipments, etc.

Fault Location Estimation Algorithm in the Railway High Voltage Distribution Lines Using Flow Technique (반복계산법을 이용한 철도고압배전계통의 고장점표정 알고리즘)

  • Park, Kye-In;Chang, Sang-Hoon;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.71-79
    • /
    • 2008
  • High voltage distribution lines in the electric railway system placed according track with communication lines and signal equipments. Case of the over head lines is occurrence the many fault because lightning, rainstorm, damage from the sea wind and so on. According this fault caused protection device to wrong operation. One line ground fault that occurs most frequently in railway high voltage distribution lines and sort of faults is line short, three line ground breaking of a wire, and so on. For this reason we need precise maintenance for prevent of the faults. The most important is early detection and fast restoration in time of fault for a safety transit. In order to develop an advanced fault location device for 22.9[kV] distribution power network in electric railway system this paper deals with new fault locating algorithm using flow technique which enable to determine the location of the fault accurately. To demonstrate its superiorities, the case studies with the algorithm and the fault analysis using PSCAD/EMTDC (Power System Computer Aided Design/Electro Magnetic Transients DC Analysis Program) were carried out with the models of direct-grounded 22.9[kV] distribution network which is supposed to be the grounding method for electric railway system in Korea.

THERMAL-FLUID ANALYSIS FOR COOLING PERFORMANCE IMPROVEMENT OF 3.3KV(105A) COMPACT RACK TYPE MEDIUM VOLTAGE INVERTER SYSTEM (3.3kV(105A) COMPACT RACK TYPE 고압 인버터 시스템의 방열 성능 향상을 위한 열유동 해석)

  • Kim, S.Y.;Kim, S.D.;Ryoo, S.R.;You, N.K.;Kim, T.B.;Hong, C.O.;Ko, H.S.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.24-28
    • /
    • 2014
  • With ever rising concerns about saving of fossil fuel resource, there have been an increasing demand for use of energy more efficiently. The electric motor driven inverters can be a great help to improve energy efficiency. They are also used to control the motor speed to the actual need. Therefore the use of them can lead to reduce energy consumption. In particular, the medium voltage(MV) drive systems used for pumps, fans, steel rolling mills and tractions have widespread applications in the industry. They cover power ratings from 0.4MW to 40MW at the MV level of 2.3kV to 13.8kV. The majority of the installed MV drive systems however, are in the 1MW to 4MW range with voltage rating from 3.3kV to 6.6kV. But they are required to reduce size and weight like other power electronic equipments. In this paper, we studied on the 3.3kV(105A) compact rack type inverter system for improving the cooling efficiency. At first, we confirmed the tendency of temperature with computational simulation using ANSYS ICEPAK and actual experimental tests. And then we researched thermal performance improvement designs in order to reduce temperature of the transformer for the safe operation. It can reduce temperature of transformer that using pipe type flow guide in the system. As a result, we found out more efficient solution by thermal-fluid analysis.

A Study on the Decision Strategy of Investment Priority Focused on Economics in Distribution Network (경제성에 기반한 배전계통 설비투자 우선순위 결정에 관한 연구)

  • Park, Chang-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.31-39
    • /
    • 2009
  • This paper shows prioritization process for equipment investment plans considering reliability indices and economical efficiency. To decide prioritization of distribution investment projects, we made a distribution system model using system configuration, it's component and load information and designed several investment alternatives to improve reliability of present system. Lastly, we proposed a evaluation model of economical efficiency assessment on distribution investment alternative projects. To analyze influence by reliability and economical efficiency, we produced economical effects with applying time-varying failure rate of KEPCO's main equipments of distribution system and interruption cost of electric power affected by investment. Finally, in order to insure the validity of this proposed methodology, we compared investment prioritization by economical evaluation with that of real investment alternatives of KEPCO's branch office. In conclusion, this paper shows what and how to interpret the reliability effects of distribution system investments into financial indicators beneficial for power utilities's managers to make decision on the perspective of corporate value.

Noise Elimination Algorithm for Detecting Partial Discharge of Generator Stator Winding Considering Relation of Periphery Signals (고압 회전기 고정자 권선의 부분방전 계측 시 주변 신호 관계를 고려한 노이즈 제거기법)

  • Shin, Hee-Sang;Cho, Sung-Min;Kang, Chul;Kang, Dong-Sik;Cho, Kuk-Hee;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.17-24
    • /
    • 2008
  • Recently, the importance of supplying the reliable electric power is increasing. therefore, the importance of diagnosis of power equipments is increasing also. Breaking insulation of stator windings is major cause of faults in high voltage generators. On-line PD (Partial Discharge) detection using Capacitive Coupler at stator windings is used widely to diagnose high voltage generator. However, precise PD(Partial Discharge) detection is impossible if detected signals are mixed with PD and noise signal. In this paper, we analyze detected signals using Capacitive Coupler at 13[kV] hydroelectric generator stator winding and suggest not hardware method but noise elimination algorithm for detecting PD of generator stator winding considering relation of periphery signals.

A Study on the Network Architecture for KEPCO SCADA Systems (한국전력 스카다 시스템의 네트워크 구조에 대한 연구)

  • Ryo, Woon Jong
    • Industry Promotion Research
    • /
    • v.2 no.2
    • /
    • pp.1-6
    • /
    • 2017
  • SCADA (Supervisory Control and Data Acquisition) System was first introduced to the Seoul Electricity Authority, which manages the transportation part among the three business fields that produce, transport and supply electric power in Korea. Has been using the data link with 1200 bps and 9600 bps in 5 protocols such as HARRIS 6000, BSC, HDLC, L & N and Toshiba by configuring 3 layers of EMS, SCADA and RTU computer equipments in 1: N radial form. This paper presents the OSI standard network packet flow, analyzing DataLink and Network Layer, and presents a KEPCO SCADA network model composed of X.25 high - speed communication network using 3 layers of network. We proposed a future SCADA communication structure that improved the current SCADA communication structure, defined the SCADA DB structure, introduced the concept of the remote SCADA gateway to the SCADA functional structure, applied the standard communication protocol, Multiplexing of surveillance and control in other local facilities and ensuring communication openness.

A study on Actual Condition and Interfererence of Electromagnetic Fields inside of The Hospital (I) (의료기관내 전자파환경 실태와 그 영향 (I))

  • Lee, Jun-Ha;Shin, Hyun-Jin;Yoo, Heum
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.53-67
    • /
    • 1997
  • General hospitals have being under the influence of various and specific environment of electromagnetic field. The factors are development of medical electric equipment and device with enlarged functional demands, in high power and multi-frequency. It has all of both faces, EMI(electromagnetic interference) and EMS(electromagnetic susceptibility). In additional, expansion of personal communication system(cellular phone) has many unreliable factor of using time and area, making noise of electromagnetic fields. We studied actual conditions of EMI in the medical site, where is numerous medical equipment, especially central operation room and ICU(intensive care unit), AKR(artificial kidney room : hemo-dialysis unit), etc. The influence, most of medical equipments made electromagnetic nosie has various factors in its band of frequency, harmonics and strength. In the experimental use of electro-surgical unit and cellular phone, noticeable and considerable noise of eletromagnetic fields were measured. All of that can make trouble and errors on the steadiness of bioelectrical devices. In conclusion, It is necessary to reconsiderations of reallocating EMI source vs. EMS factor, and set to definite forbiding area of using cellular phone. For maintenance of steady normal conditions, in spite of existing any other legal standards of safty level, it need considering all of alternative electromagnetic situations on a case-by-case basis.

  • PDF