• Title/Summary/Keyword: Electric machinery

Search Result 551, Processing Time 0.06 seconds

Multi-phase Accelerating Test Method of Thermal Aging Considering Heat Generation of Electric Equipment (전기기기의 발열을 고려한 다단계 가속열노화 방법)

  • Lim, Byung-Ju;Park, Chang-Dae;Chung, Kyung-Yul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.5
    • /
    • pp.18-23
    • /
    • 2013
  • Thermal aging test is performed to qualify the life time of equipment in thermally aged condition. Due to long life time more than 10 years like as in power plant, the equipment is subjected to the accelerated thermal aging condition which is able to shorten the long aging test period by increasing aging temperature. Normally, conservatism of thermal aging test causes to impose unbalanced and excessive thermal load on components of the equipment, and deformation and damage problems of the components. Additionally, temperature rise of each component through heat generation of the electric equipment leads to long-term problem of the test period. Multi-phase accelerating aging test is to perform thermal aging test in multiple aging conditions after dividing into groups with various components of equipment. The groups might be classified considering various factors such as activation energy, temperature rise, glass transition temperature and melting temperature. In this study, we verify that the multi-phase accelerating aging test method can reduce and equalize the thermal over load of the components and shorten aging test time.

Effect of dipole electric field on low-voltage pentacene thin film transistors

  • Kim, Kang-Dae;Song, Chung-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1636-1638
    • /
    • 2007
  • We report on low-voltage pentacene TFTs with a Al2O3/OTS as a gate dielectric. Improving device characteristics, we performed chemical modification of self-grown Al2O3 surface with an octadecyltrichlorosilane(OTS) self-assembled monolayer(SAM). As the result of this combination, the mobility was improved from 0.3 to $0.45\;cm^2/Vs$. In addition, we examined that the SAM dipole electric field have an influence on gate leakage current, transfer and output characteristics.

  • PDF

Cooling performance test of the superconducting fault current limiter

  • Yeom, H.;Hong, Y.J.;In, S.;Ko, J.;Kim, H.B.;Park, S.J.;Kim, H.;Kim, H.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.66-70
    • /
    • 2014
  • The superconducting fault current limiter (SFCL) is an electrical power system device that detects the fault current automatically and limits the magnitude of the current below a certain safety level. The SFCL module does not have any electrical resistance below the critical temperature, which facilitates lossless power transmission in the electric power system. Once given the fault current, however, the superconducting conductor exhibits extremely high electrical resistance, and the magnitude of the current is accordingly limited to a low value. Therefore, SFCL should be maintained at a temperature below the critical temperature, which justifies the cryogenic cooling system as a mandatory component. This report is a study which reported on the cooling system for the 154 kV-class hybrid SFCL owned by Korea Electric Power Corporation (KEPCO). Using the cryocooler, the temperature of liquid nitrogen (LN2) was lowered to 71 K. The cryostat was pressurized to 5 bars to improve the dielectric strength of nitrogen and suppress nitrogen bubble foaming during operation of SFCL. The SFCL module was immersed in the liquid nitrogen of the cryostat to maintain the superconducting state. The performance test results of the key components such as cryocooler, LN2 circulation pump, cold box, and pressure builder are shown in this paper.

Verification of dilution ratio of the newly developed ejector-porous tube diluter for measurement of fine dust in coal-fired power plant stack (화력발전소 굴뚝 미세먼지 측정을 위해 개발한 이젝터-다공튜브 희석장치의 희석비 검증)

  • Shin, Dongho;Kim, Young-Hoon;Hong, Keejung;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Lee, Ga-Young;Chun, Sung-Nam;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.15 no.3
    • /
    • pp.105-113
    • /
    • 2019
  • The exhaust emissions from coal-fired power plants have received much attention because coal-fired power plants are the one of the largest sources of particulate matter (PM) emissions in South Korea. To measure the PM10 and PM2.5, we developed the novel diluter which is comprised of ejector and porous tube in series. The dilution ratio must be defined to calculate particle concentrations of the sampled air as well as to probe match for the isokinetic sampling. For this reason, we verified the dilution ratio of the developed diluter by the flow rate, numerical solution, gas concentration and particle concentration. The ejector-supplied flow rates were 10-50 L/min and the porous tube-supplied flow rates were 30, 50 L/min in this study. All methods above showed similar dilution ratios to each other within 10 % error rate. The dilution ratio was confirmed by comparing mass concentrations before and after the dilution process.

A Performance Test Equipment for Rechargeable Electric Tools

  • Lee, Jong-Kwang;Lim, Hyo-Jae;Park, Min-Kyu;Koh, Jin-Ha;Lee, Kyu-Won;Kang, E-Sock
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.68.5-68
    • /
    • 2002
  • For the performance test of rechargeable electric tools, it is necessary to test under the same condition as the actual operation condition. They are necessary to control the load torque and to acquire the test data with a computer, and it should be convenient to fix the tool on the test equipment for rechargeable electric tools. It consists of torque loading parts, sensing parts and control software. Two hysteresis brakes, connected serially with flexible coupling, were applied to control the load for the test. The sensing part consists of a torque sensor, a rpm detector and a power analyzer. The torque and the rpm were measured in order to calculate the output of the rechargeable electric...

  • PDF

Development of the compacted extra high voltage by-pass cable machinery (콤팩트화된 특고압 이동형 케이블 장치의 개발)

  • Ahn, Y.K.;Seo, S.J.;Paeck, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.268-270
    • /
    • 1991
  • In this paper, we introduce the 22.9kv by-pass cable machinery being developed. This machinery is so desinged as to solve many problems of the conventional one such as the limitation of usage, working space, route length etc. It is, so to speak, one touch-one system. Compared with the conventional system, this has several advantages, which are the cost down, the decreasing working time and space, and the multiusage etc.

  • PDF

Estimation of Thermal History in XLPE Insulated Cable during Heat Cycle Test (Heat Cycle Test에서 XLPE 절연체에 인가되는 열이력의 추정)

  • Kim, Young-Ho;Lee, Sang-Jin;Lee, Gun-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1425-1427
    • /
    • 1998
  • The thermal history of XLPE insulated cable during heating cycle voltage test specified by IEC 840 was examined by DSC(differential scanning calorimetry) method, of which the principal is on the basis of the phenomenon that the crystals in polyethylene are rearranged as it is annealed near/below the melting temperature. From the result, it can be estimated that XLPE insulation near the conductor was exposed at the temperature of about $100^{\circ}C$ with the electrical stress through the test.

  • PDF

A Study on the Power Line Control System for Electric Machinery using Power Line Communication (전력선 반송통신을 이용한 전기기기 전원 제어 시스템에 관한 연구)

  • 김경엽;문복산;김영일;서인호;천행춘;강대기;유영호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.115-122
    • /
    • 2000
  • Recently, a study on the Power Line Communication has been done by many companies and institutes due to its own merits that we can use the power line as a communication channel. But, there are serious problems about the harsh and unpredictable characteristics - noise, signal distortion and attenuation to be overcome in order that we commercialize the Power Line Communication. In this paper, we analyse the power line characteristics and apply the technology of PLC to control power of electric machinery by using ASK modulation.

  • PDF

A Study on the Effecient Mesh Generation for Finite Element Analysis of Electric Machinery (전기기기의 유한 요소 해석을 위한 효율적인 요소 생성에 관한 연구)

  • Kim, Jin-Tae;Jeong, Tae-Gyeong;Kim, Hyeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.174-181
    • /
    • 1999
  • To obtain more accurate result in the finite element analysis for electric machinery, it is important to have a mesh being of good quality. This paper describes a new technique of mesh generation for the finite element method. When the list of points defining the region of analysis is given, an appropriate distribution of interior points is generated first. Secondly the points are connected to from the trianlges. Finally the connectivity data are used to reposition the interior points using Laplacian smoothing and mesh relaxation technique. In this paper, a mesh searching technique of Lawson which modifies the start mesh is proposed in addition to the above three steps. This algorithm is simple and produces the meshes being of good quality with high speed in comparison with the existing one.

  • PDF