• Title/Summary/Keyword: Electric leakage

Search Result 584, Processing Time 0.031 seconds

A Study on the Distribution of Heavy Metal Concentrations in Marine Surface Sediments around Samcheonpo Power Plant (삼천포화력발전소 주변해역 표층퇴적물중의 중금속원소함량 분포 연구)

  • Lee, Doo-Ho;Lim, Ju-Hwan;Jeon, Byeong-Yeol;Jeong, Nyeon-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • An environmental geochemical survey of heavy metal distribution in marine surface sediments around the ocean of Samcheonpo coal-fired power plant was conducted to investigate the possibility of coal-ash leakage from ash pond and the associated heavy metal pollution in sedimental deposits due to the operation of the coal-fired power plant. The X-Ray Diffractometry (XRD) analysis showed that the main leakage point of coal-ash was limited to a single site of the first ash pond. It also appeared that the amounts of organic carbon and metal elements were positively correlated to the grain size distribution, and that Co, Cr, Cu, Fe, Ni, and Zn were bounded to organic ligands. However, the distributions of Cd, Hg, and Mn did not have any significant correlation with the sediment grain size and organic matters. In particular, the distribution of Cd appeared to be affected by the concentration of the carbonate materials in the study area.

  • PDF

Electromagnetic Interference Suppression Method of Motor Assembly for Aircraft Application (항공용 모터 조립체의 전자기 간섭 감쇠 방안)

  • Kim, Jee-Heung;Ryu, Hong-Kyun;Park, Beom-Jun;Park, Young-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.351-358
    • /
    • 2018
  • In this study, we propose a method of suppressing the leakage noise signal of motor assembly through the test. The motor assembly is mounted on outside of the aircraft to rotate an antenna and must satisfy RE102 requirement on MIL-STD-461F in terms of electromagnetic interference. It is confirmed by RE102 test result hat the leakage noise signal of the equipment occurs due to external influx through the power and control cable and rotation of the motor. And it is ascertained that the part where internal/external physical shielding is difficult to rotate is the leakage path. To reduce the leakage noise signal, the electrical ground reinforcement and the electric shielding structure considering the operation of the equipment is applied and it is verified that the requirement is satisfied. Finally, we verified that required specification are met by applying circular corrugated choke with interlocking shapes and conductive grease to the noise leakage path.

The Analysis on the Electric Potential Distribution of Dry and Submerged Condition by Electric Leakage in Street Lamp (가로등설비 누전시 건조상태와 침수상태에 대한 전위분포 분석)

  • Hon, Sung-Ho;Park, Sang-Tea;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.44-50
    • /
    • 2008
  • This paper presents study on the electric potential distribution when have a short in street lamp. In order to measure electric potential testing ground is built in. A experiment is conducted to simulate dry and submerged situation of street lamp. The street lamp is leaked by artificial means. And electric potential is measured in grounded street lamp and street lamp alone. The results show that touch voltage of grounded street lamp is possible more high than street lamp alone. And the electric shock hazard is high because high electric potential is distributed near submerged street lamp. Also if street lamp is submerged ground is not useful to decrease electric shock hazard.

Gate Oxide 두께에 따른 NMOSFET소자의 전기적 특성 분석

  • Han, Chang-Hun;Lee, Gyeong-Su;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.350-350
    • /
    • 2012
  • 본 연구에서는 Oxide 두께가 각각 4, 6 nm인 Symmetric NMOSFET의 전기적 특성 분석에 관한 연구를 진행하였다. 게이트 전압에 따른 Drain saturation current (IDSAT), Threshold Voltage(VT) 및 드레인 전압에 따른 Off-states 특성 변화를 분석하였다. 소자 측정 결과 oxide 두께가 4 nm인 경우 Vt는 0.3 V, IDSAT은 73 ${\mu}A$ (@VD=0.05)로, oxide 두께가 6 nm인 경우 Vt는 0.65 V, IDSAT은 66 ${\mu}A$ (@VD=0.05)로 각각 측정되었다. 이는 oxide 두께가 얇은 경우 게이트 전압 인가 시 Electric field 증가에 따른 것으로 판단된다. 또한 드레인 전압 인가에 따른 소자 특성 분석 결과 oxide 두께가 4nm인 경우 급격한 Gate leakage 증가를 보였으며, 이에 따라 Off-state에서의 leakage current가 증가함을 확인하였다. 본 연구는 Oxide 두께에 따른 MOSFET 소자의 전기적 특성 분석을 위해 진행되었으며, 상기 결과와 같이 oxide 두께 가변은 Idsat, Vt, leakage current 등의 주요 파라미터에 영향을 주어 NMOSFET 소자의 전기적 특성을 변화시킴을 확인하였다.

  • PDF

Fabrication of the LDD Structure poly-Si TFT with Excimer Laser Recrystallization Process (Excimer laser로 재결정화한 LDD구조의 poly-Si TFT 제작)

  • 정준호;박용해
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.2
    • /
    • pp.324-331
    • /
    • 1995
  • The leakage current characteristics of the low temperature processed LDD structure poly-Si TFT is analyzed. The excimer laser technology was applied to the recrystallization process of poly-Si film and the maximum processing temperature was retained under 600.deg.C. From the fabricated LDD space 0.3.mu.m to 3$\mu$m, the best on/off current ration could be obtained with the 1.3$\mu$m LDD space. And the threshold voltage did not increase more than 4V over 0.8$\mu$m LDD space. The characteristics of leakage current was compared to non-LDD structure TFT to analyze the mechanism of leakage current. Consequently, it could be concluded that the leakage current is strongly affected by the trap states as well as high electric field between gate and drain.

  • PDF

A Study on the Leakage Current Voltage of Hybrid Type Thin Films Using a Dilute OTS Solution

  • Kim Hong-Bae;Oh Teresa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.21-25
    • /
    • 2006
  • To improve the performance of organic thin film transistor, we investigated the properties of gate insulator's surface according to the leakage current by I-V measurement. The surface was treated by the dilute n-octadecyltrichlorosilane solution. The alkyl group of n-octadecyltrichlorosilane induced the electron tunneling and the electron tunneling current caused the breakdown at high electric field, consequently shifting the breakdown voltage. The 0.5% sample with an electron-rich group was found to have a large leakage current and a low barrier height because of the effect of an energy barrier lowered by, thermionic current, which is called the Schottky contact. The surface properties of the insulator were analyzed by I-V measurement using the effect of Poole-Frankel emission.

  • PDF

Considering design parameters in terms of rail potential and leakage current in DC feeding system (직류급전시스템의 레일전위와 누설전류 관점에서의 설계 파라미터 연구)

  • Han, Moon-Seob;Jung, Ho-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.236-241
    • /
    • 2007
  • DC feeding system is mainly floating but the rail potential and the leakage current are created because of long parallelism between rails and ground. Rail potential causes electric shock to human and leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important recent DC feeding system. Normally during designing DC feeding system in terms of rail potential and leakage current, there are about 10 parameters. Four design parameters among those is analysed based on propagation theory that is utilized in order to simulate grounding system.

  • PDF

The conductive characteristic of oil-immersed paper (유침절연지의 도전특성)

  • 성영권;이헌용
    • 전기의세계
    • /
    • v.25 no.2
    • /
    • pp.87-91
    • /
    • 1976
  • Experimentally to investigate the conductive characteristic of oil-immersed paper, we observed the leakage current-voltage characteristic of oil-immersed paper, the temperature dependence of ionization rate and the effect of metal electrode on the leakage current. The results showed that the leakage current-voltage characteristic generally followed the experimental equation i=i$_{0}$ exp (K.root.E) and the slope K did not change by the temperature and electric strength, but only when the direct voltage was applied. And also the leakage current seemed to depend on the work function of metal electrode. From the above results we concluded that the deterioration of oil-immersed paper was not only caused by the thermionic emission from the cathode but also by the conductive property of oil-immersed paper in itself and the work function of metal electrode.e.

  • PDF

Development of data acquisition and analysis program modules for leakage current of polymeric insulators using the Labview software (Labview를 이용한 배전용 폴리머애자의 누설전류 측정 및 분석 프로그램 개발)

  • Cho, Seong-Soo;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1969-1971
    • /
    • 2000
  • This paper presents a data acquisition and analysis program modules that has been developed using the Labview program. These program modules can use to acquire and analyze leakage current data of insulator under different contamination conditions. The experimental hardware made up salt fog chamber, AC/DC power supply, transducer (shunt resistor), measurement devices and PC with the GPIB (General Purpose Interface Bus). And analysis program modules can calculate pulse level count, accumulated charge, average leakage current, power spectrum, and harmonics. The result of applying these analytical program modules to polymeric insulator is available for evaluation of leakage current characteristic of outdoor insulators.

  • PDF

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.