• Title/Summary/Keyword: Electric fraction

Search Result 210, Processing Time 0.026 seconds

Chemical Composition of Rainwater in Suwon and Ansung Area (수원과 안성지역 빗물의 화학성분 조성)

  • Lee, Jong-Sik;Kim, Bok-Young;Kim, Jin-Ho;Hong, Seung-Gil
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.2
    • /
    • pp.169-173
    • /
    • 1999
  • To investigate the chemical properties of rainwater in the southern part of gyeonggi Province, the rainwater was collected in Suwon and Ansung for six months from May to October in 1998, and analyzed its chemical composition. The ion balance and electric conductivity balance showed confidence to chemical analyses of rainwater. The most frequent pH range of rainwater was pH $5.0{\sim}5.6$ both in Suwon and Ansung area with distribution ratio of 37.9% and 35.3%, respectively. Among the 1mm fraction for initial 5mm of rainfall, ion concentration of initial rainwater (less than 1mm of rainfall) was higher than those of the later terms. The major ions in rainwater were $NH_4^-,\;Ca^{2+}$and $Na^+$ for cations, and $SO_4^{2-}$ and $NO_3^-$ for anions. Monthly variation of pH of rainwater showed low level of 4.2 to 4.5 in Suwon and 4.6 to 4.7 in Ansung in August and September, respectively. The $nss-SO_4^{2-}/NO_3^-$ ratio of rainwater in Suwon and Ansung area were 2.2 and 2.9 which means nonsea salt $SO_4^{2-}$ contrbuted to acidity of rainwater more in Ansung than Suwon area.

  • PDF

Regression of Left Ventricular Hypertrophy after AVR in Aortic Valvular Stenosis (대동맥판막협착증 환자에서 판막치환 후 좌심실심근비후의 변화)

  • 이재원;최강주;송명근
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.586-590
    • /
    • 1998
  • Background: The regression of the left ventricular hypertrophy after prosthetic valve replacement in patients with aortic valvular stenosis is an important factor to determine the appropriateness of the replaced prosthetic valvular size. Methods: To assess the regression of myocardial hypertrophy, a retrospective analysis of Doppler echocardiographic and electrocardiographic data was undertaken before, soon after(7.5$\pm$2.1 day), and late after(10.7$\pm$1.8 months) surgery in 36 patients(22 males, 14 female, mean age 54$\pm$12.1 years, mean BSA 1.61$\pm$0.15m2) with predominant aortic valvular stenosis. The patients underwent St. Jude Medical aortic valve replacement. By the size of the valves used, the patients were divided into three groups(19, 21 and 23+). Results: The mean body surface area(1.48$\pm$0.13) in the patients with the 19 mm valve was smaller than that in the other groups(1.63$\pm$0.12)(p<0.05). No significant changes of ejection fraction were detected in all groups over time. Left ventricular muscle mass index(gm/m2) was reduced significantly in the 21 and 23+ groups over time(p<0.05), but there were no significant changes in the 19 mm valve group. The electric voltage height on EKG at the period of late after surgery was reduced significantly in all groups(p<0.05). Conclusion: Despite clinical improvement, the LVH was not reduced significantly in 19 mm valve group. Thus we suggest that more attention and additional procedures such as annular enlargement should be taken in patients who will undergo the replacement of 19 mm prosthetic valve.

  • PDF

Pollution Characteristics of Rainwater at Jeju Island during 2009~2010 (2009~2010년 제주지역 강우의 오염 특성 연구)

  • Kim, Ki-Ju;Bu, Jun-Oh;Kim, Won-Hyung;Lee, Yoon-Sang;Hyeon, Dong-Rim;Kang, Chang-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.818-829
    • /
    • 2013
  • The collection of rainwater samples was made at Jeju area during 2009~2010, and the major ionic species were analyzed. In the comparison of ion balance, conductivity, and acid fraction for the validation of analytical data, the correlation coefficients showed a good linear relationship within the range of 0.966~0.990. The volume-weighted mean pH and electric conductivity were 4.9 and $17.8{\mu}S/cm$, respectively, at the Jeju area. The volume-weighted mean concentrations of ionic species in rainwater were in the order of $Cl^-$ > $Na^+$ > $nss-SO_4{^{2-}}$ > $NH_4{^+}$ > $NO_3{^-}$ > $Mg^{2+}$ > $H^+$ > $nss-Ca^{2+}$ > $HCOO^-$ > $K^+$ > $PO_4{^{3-}}$ > $CH_3COO^-$ > $NO_2{^-}$ > $F^-$ > $HCO_3{^-}$ > $CH_3SO_3{^-}$. The ionic strength of rainwater was $0.26{\pm}0.21$ mM during the study period. The composition ratios of ionic species were such as 50.1% for the marine sources ($Na^+$, $Mg^{2+}$, $Cl^-$), 30.9% for the anthropogenic sources ($NH_4{^+}$, $nss-SO_4{^{2-}}$, $NO_3{^-}$), and 4.7% for the soil source ($nss-Ca^{2+}$), and 3.1% for organic acids ($HCOO^-$, $CH_3COO^-$). From the seasonal comparison, the concentrations of $NO_3{^-}$, $nss-Ca^{2+}$, and $nss-SO_4{^{2-}}$ increased in winter and spring seasons, indicating a reasonable possibility of long range transport from Asia continent. Especially, the acidifying contributions by major inorganic acids ($nss-SO_4{^{2-}}$ and $NO_3{^-}$) and organic acids ($HCOO^-$ and $CH_3COO^-$) were 87.6% and 12.4%, respectively. In comparison by sectional inflow pathway of air mass during the rainy sampling days, the concentrations of $nss-SO_4{^{2-}}$ and $NO_3{^-}$ were relatively high when the air mass was moved from the China continent into Jeju area.

A Study on Flame Extinction in Oxymethane Combustion (메탄 산소 연소에 있어서 화염 소화에 대한 연구)

  • Kim, Tae Hyung;Kwon, Oh Boong;Park, Jeong;Keel, Sang-In;Yun, Jin-Han;Park, Jong Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.4
    • /
    • pp.34-41
    • /
    • 2015
  • Oxy-methane nonpremixed flames diluted with $CO_2$ were investigated to clarify impact of radiation heat loss and chemical effects of additional $CO_2$ to oxidizer stream on flame extinction. Flame stability maps were presented with functional dependencies of critical diluents mole fraction upon global strain rate at several oxidizer stream temperatures in $CH_4-O_2/N_2$, $CH_4-O_2/CO_2$, and $CH_4-O_2/CO_2/N_2$ counterflow flames. The effects of radiation heat loss on the critical diluent mole fractions for flame extinction are not significant even at low strain rate in nonpremixed $CH_4-O_2/N_2$ diffusion flame, whereas those are significant at low strain rate and are negligible at high strain rate (> $200s^{-1}$) in $CH_4-O_2/CO_2$ and $CH_4-O_2/CO_2/N_2$ counterflow flames. Chemical effects of additional $CO_2$ to oxidizer stream on the flame extinction curves were appreciable in both $CH_4-O_2/CO_2$ and $CH_4-O_2/CO_2/N_2$ flames. A scaling analysis based on asymptotic solution of stretched flame extinction was applied. A specific radical index, which could reflect the OH population in main reaction zone via controlling the mixture composition in the oxidizer stream, was identified to quantify the chemical kinetic contribution to flame extinction. A good correlation of predicted extinction limits to those calculated numerically were obtained via the ratio between radical indices and oxidizer Lewis numbers for the target and baseline flames. This offered an effective approach to estimate extinction strain rate of nonpremixed oxy-methane flames permitting air infiltration when the baseline flame was taken to nonpremixed $CH_4-O_2/N_2$ flame.

Study on the Micellization of CPC/Brij 35 Mixed Surfactant Systems in Water (순수 물에서 CPC/Brij 35 혼합계면활성제의 미셀화에 대한 연구)

  • Gil, Han-Nae;Lee, Byung-Hwan
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.2
    • /
    • pp.118-124
    • /
    • 2009
  • The values of critical micelle concentration (CMC) and counter ion binding constants (B) in a micellar state of CPC (1-hexadecylpyridinium chloride) with Brij 35 (polyoxyethylene(23) lauryl ether) in water were determined as a function of ${\alpha}_1$ (the overall mole fraction of CPC) by the use of electric conductivity method. Various thermodynamic parameters ($X_i,\;{\gamma}_i,\;C_i,\;a_{i}^{M},\;\beta,\;and\;{\Delta}H_{mix}$) were calculated and analyzed by means of the equations derived from the non-ideal mixed micellar model. And thermodynamic parameters (${\Delta}{G^o}_m,\;{\Delta}{H^o}_m,\;and\;{\Delta}{S^o}_m$) for the micellization of CPC/Brij 35 mixtures were also calculated from the temperature dependence of the CMC values. The values of ${\Delta}{G^o}_m$ are all negative, but the values of ${\Delta}{S^o}_m$ and ${\Delta}{H^o}_m$ are positive or negative, depending on the measured temperature and ${\alpha}_1$.

Analysis of Crushing/Classification Process for Recovery of Black Mass from Li-ion Battery and Mathematical Modeling of Mixed Materials (폐배터리 블랙 매스(black mass) 회수를 위한 파쇄/분급 공정 분석 및 2종 혼합물의 수학적 분쇄 모델링)

  • Kwanho Kim;Hoon Lee
    • Resources Recycling
    • /
    • v.31 no.6
    • /
    • pp.81-91
    • /
    • 2022
  • The use of lithium-ion batteries increases significantly with the rapid spread of electronic devices and electric vehicle and thereby an increase in the amount of waste batteries is expected in the near future. Therefore, studies are continuously being conducted to recover various resources of cathode active material (Ni, Co, Mn, Li) from waste battery. In order to recover the cathode active material, black mass is generally recovered from waste battery. The general process of recovering black mass is a waste battery collection - discharge - dismantling - crushing - classification process. This study focus on the crushing/classification process among the processes. Specifically, the particle size distribution of various samples at each crushing/classification step were evaluated, and the particle shape of each particle fraction was analyzed with a microscope and SEM (Scanning Electron Microscopy)-EDS(Energy Dispersive Spectrometer). As a result, among the black mass particle, fine particle less than 74 ㎛ was the mixture of cathode and anode active material which are properly liberated from the current metals. However, coarse particle larger than 100 ㎛ was present in a form in which the current metal and active material were combined. In addition, this study developed a PBM(Population Balance Model) system that can simulate two-species mixture sample with two different crushing properties. Using developed model, the breakage parameters of two species was derived and predictive performance of breakage distribution was verified.

Ionic composition and pollution characteristics of precipitation in Jeju Island during 2009-2014 (2009-2014년 제주지역 강수의 이온조성 및 오염특성)

  • Bu, Jun Oh;Song, Jung Min;Shin, Su Hyun;Kim, Won Hyung;Kang, Chang Hee
    • Analytical Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.19-28
    • /
    • 2016
  • The objective of this study was to determine the acidification of precipitation in the Jeju area. Precipitation samples were collected from the Jeju area from 2009-2014, and the major ionic species were analyzed. In the regression analysis, through a comparison of ion balance, electric conductivity, and acid fraction, the correlation coefficients showed a good linear relationship within the range of 0.927~0.983. The volume-weighted means of the pH and electric conductivity were 4.9 and 22.7 µS/cm, respectively. The ionic strength of precipitation was 0.27±0.38 mM, indicating about 35.9 % of total precipitation within the pure precipitation criteria. The volume-weighted mean concentrations (ìeq/L) of the ionic species in the precipitation were in the order of Na+ > Cl > nss-SO42− > NO3 > NH4+ > Mg2+ > H+ > nss-Ca2+ > PO43− > K+ > HCOO > CH3COO > NO2 > F > HCO3 > CH3SO3 . The acidification contributions by sulfuric and nitric acids were 54.5 % and 36.5 %, respectively. Meanwhile the acidification contributions by formic and acetic acids were 4.8 % and 4.2 %, respectively. Thus, it was found that the acidification of the precipitation in the Jeju area was mainly due to the inorganic acids. The neutralization factors by NH3 and CaCO3 were also 33 % and 20 %, respectively.

Chemical characteristics of wet precipitation in urban and mountainous sites of Jeju Island

  • Bu, Jun-Oh;Song, Jung-Min;Park, Sook-Young;Kang, Hee-Ju;Kang, Chang-Hee
    • Analytical Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.33-41
    • /
    • 2020
  • Wet precipitation samples were collected in Jeju City and Mt. Halla-1100 site (a site at an altitude of 1100 m on Mt. Halla) during 2011-2013, and their major ionic species were analyzed to examine the chemical composition and characteristics. A comparison of ion balance, electric conductivity, and acid fraction of precipitation revealed correlation coefficients in the range of r = 0.950~0.991, thereby implying the high quality of analytical data. Volume-weighted mean pH and electric conductivity corresponded to 4.86 and 25.5 µS/cm for Jeju City, and 4.98 and 15.1 µS/cm for Mt. Halla-1100 site, respectively. Ionic strengths of the wet precipitation in Jeju City and Mt. Halla-1100 site corresponded 0.3 ± 0.5 and 0.2 ± 0.2 mM, respectively, thereby indicating that more than 30 % of total precipitation was within a pure precipitation criteria. The precipitation with a pH range of 4.5 - 5.0 corresponded to 40.8 % in Jeju City, while the precipitation with a pH range of 5.0 - 5.5 corresponded to 56.9 % in Mt. Halla-1100 site, thereby indicating slightly more weak acidity than that in Jeju city. The volume-weighted mean concentration (µeq/L) of ionic species was in the order of Na+ > Cl- > nss-SO42- > NO3- > Mg2+ > NH4+ > H+ > nss-Ca2+ > PO43- > K+ > CH3COO- > HCOO- > NO2- > F- > HCO3- > CH3SO3- at Jeju City area, while it corresponded to Na+ > Cl- > nss-SO42- > NO3- > NH4+ > H+ > Mg2+ > nss-Ca2+ > PO43- > CH3COO- > K+ > HCOO- > NO2- > F- > HCO3- > CH3SO3- at Mt. Halla-1100 site. The compositions of sea salts (Na+, Cl-, Mg2+) and secondary pollutants (NH4+, nss-SO42-, NO3-) corresponded to 66.1 % and 21.8 %, respectively, in Jeju City and, 49.9 % and 31.5 %, respectively, in Mt. Halla-1100 site. The acidity contributions in Jeju City and Mt. Halla-1100 site by inorganic acids, i.e., sulfuric acid and nitric acid, corresponded to 93.9 % and 91.4 %, respectively, and the acidity contributions by organic acids corresponded to 6.1 % and 8.6 %, respectively. The neutralization factors in Jeju City and Mt. Halla1100 site by ammonia corresponded to 29.8 % and 30.1 %, respectively, whereas the neutralization factors by calcium carbonate corresponded to 20.5 % and 25.2 %, respectively. From the clustered back trajectory analysis, the concentrations of most ionic components were higher when the airflow pathways were moved from the continent to Jeju area.

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

Effects of acid-treatment conditions on the surface properties of the RBM treated titanium implants (산-처리 조건이 RBM처리한 티타늄 임플란트의 표면 특성에 주는 영향)

  • Lee, Han-Ah;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.257-274
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of acid-treatment conditions on the surface properties of the RBM (Resorbable Blast Media) treated titanium. Disk typed cp-titanium specimens were prepared and RBM treatments was performed with calcium phosphate ceramic powder. Acid solution was mixed using HCl, $H_2SO_4$ and deionized water with 4 different volume fraction. The RBM treated titanium was acid treated with different acid solutions at 3 different temperatures and for 3 different periods. After acid-treatments, samples were cleaned with 1 % Solujet solution for 30 min and deionized water for 30 min using ultrasonic cleanser, then dried in the electrical oven ($37^{\circ}C$). Weight of samples before and after acid-treatment were measured using electric balance. Surface roughness was estimated using a confocal laser scanning microscopy, crystal phase in the surface of sample was analyzed using X-ray diffractometer. Surface morphology and components were evaluated using Scanning Electron Microscope (SEM) with Energy Dispersive X-ray spectroscopy (EDX) and X-ray Photoemission Spectroscopy (XPS). Values of the weight changes and surface roughness were statistically analyzed using Tukey-multiple comparison test (p=0.05). Weight change after acid treatments were significantly increased with increasing the concentration of $H_2SO_4$ and temperature of acid-solution. Acid-treatment conditions (concentration of $H_2SO_4$, temperature and time) did not produce consistent effects on the surface roughness, it showed the scattered results. From XRD analysis, formation of titanium hydrides in the titanium surface were observed in all specimens treated with acid-solutions. From XPS analysis, thin titanium oxide layer in the acid-treated specimens could be evaluated. Acid solution with $90^{\circ}C$ showed the strong effect on the titanium surface, it should be treated with caution to avoid the over-etching process.