• 제목/요약/키워드: Electric field calculation

검색결과 192건 처리시간 0.027초

효율적 전자상거래를 위한 유한체 서브그룹 기반의 사용자 인증 프로토콜 설계 (Design of GE subgroup based User Authentication Protocol For efficient Electric Commerce)

  • 정경숙;홍석미;정태충
    • 한국전자거래학회지
    • /
    • 제9권1호
    • /
    • pp.209-220
    • /
    • 2004
  • If protocol has fast operations and short key length, it can be efficient user authentication protocol. Lenstra and Verheul proposed XTR. XTR have short key length and fast computing speed. Therefore, this can be used usefully in complex arithmetic. In this paper, to design efficient user authentication protocol we used a subgroup of Galois Field to problem domain. Proposed protocol does not use GF(p/sup 6/) that is existent finite field, and uses GF(p²) that is subgroup and solves problem. XTR-ElGamal based user authentication protocol reduced bit number that is required when exchange key by doing with upside. Also, proposed protocol provided easy calculation and execution by reducing required overhead when calculate. In this paper, we designed authentication protocol with y/sub i/ = g/sup b.p/sup 2(i-1)//ㆍv mol q, 1(equation omitted) 3 that is required to do user authentication.

  • PDF

Calculation of Distributed Magnetic Flux Density under the Stator-Turn Fault Condition

  • Kim, Kyung-Tae;Hur, Jin;Kim, Byeong-Woo
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.552-557
    • /
    • 2013
  • This paper proposed an analytical model for the distributed magnetic field analysis of interior permanent magnet-type blush-less direct current motors under the stator-turn fault condition using the winding function theory. Stator-turn faults cause significant changes in electric and magnetic characteristic. Therefore, many studies on stator-turn faults have been performed by simulation of the finite element method because of its non-linear characteristic. However, this is difficult to apply to on-line fault detection systems because the processing time of the finite element method is very long. Fault-tolerant control systems require diagnostic methods that have simple processing systems and can produce accurate information. Thus analytical modeling of a stator-turn fault has been performed using the winding function theory, and the distributed magnetic characteristics have been analyzed under the fault condition. The proposed analytical model was verified using the finite element method.

Analysis on Temperature Distribution and Current-Carrying Capacity of GIL Filled with Fluoronitriles-CO2 Gas Mixture

  • Chen, Geng;Tu, Youping;Wang, Cong;Cheng, Yi;Jiang, Han;Zhou, Hongyang;Jin, Hua
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2402-2411
    • /
    • 2018
  • Fluoronitriles-$CO_2$ gas mixtures are promising alternatives to $SF_6$ in environmentally-friendly gas-insulated transmission lines (GILs). Insulating gas heat transfer characteristics are of major significance for the current-carrying capacity design and operational state monitoring of GILs. In this paper, a three-dimensional calculation model was established for a GIL using the thermal-fluid coupled finite element method. The calculated results showed close agreement with experimentally measured data. The temperature distribution of a GIL filled with the Fluoronitriles-$CO_2$ mixture was obtained and compared with those of GILs filled with $CO_2$ and $SF_6$. Furthermore, the effects of the mixture ratio of the component gases and the gas pressure on the temperature rise and current-carrying capacity of the GIL were analyzed. Results indicated that the heat transfer performance of the Fluoronitriles-$CO_2$ gas mixture was better than that of $CO_2$ but worse than that of $SF_6$. When compared with $SF_6$, use of the Fluoronitriles-$CO_2$ gas mixture caused a reduction in the GIL's current-carrying capacity. In addition, increasing the Fluoronitriles gas component ratio or increasing the pressure of the insulating gas mixture could improve the heat dissipation and current-carrying capacity of the GIL. These research results can be used to design environmentally-friendly GILs containing Fluoronitriles-$CO_2$ gas mixtures.

중간주파수 대역에서 준정적(Quasi-Static) FDTD 기법을 이용한 인체 유도전류 분석 (Analysis of Body Induced Current in Middle Frequency Range Using Quasi-Static FDTD)

  • 변진규
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.141-149
    • /
    • 2009
  • 본 논문에서는 준정적 FDTD 기법을 FORTRAN 프로그래밍을 통해 직접 구현하고 이를 이용해 중간주파수 대역의 인체유도전류 분포를 해석하였다. 제작된 프로그램의 타당성을 검증하기 위하여 기존 FDTD 기법을 적용하기 어려운 테스트 모델에 대한 계산결과를 이론적 해와 비교하고, 타임스텝이 크게($5.68{\times}10^6$배) 단축되는 것을 확인하였다. 검증된 수치해석 기법을 이용하여 20[kHz] 자기장과 1[MHz] 전기장에 노출된 3차원 고해상도 인체모델에 유기되는 유도전류의 분포를 계산하고, 양 발의 접지조건이 유도전류의 분포와 크기에 미치는 영향을 분석하였다. 본 연구는 인체유도전류의 안전성 평가, 생체전기 응용 진단장치 개발 등을 포함한 다양한 분야에서 활용될 것으로 기대된다.

FIELD EMISSION FROM TRIODE FIELD EMITTER WITH PLANAR CARBON-NANOPARTICLE CATHODE

  • Park, Kyung-Ho;Seo, Woo-Jong;Lee, Soon-Il;Koh, Ken-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.309-312
    • /
    • 2002
  • Triode field emitters with planar-carbon-nanopaticle (CNP) cathodes were successfully fabricated using the conventional photolithography and the hotfilament chemical vapor deposition. Electron emission from a CNP triode emitter with a 12-${\mu}m$-diameter gate hole started at the gate voltage of 45 V, and the anode current reached the level of ${\sim}120$ nA at the gate voltage of 60 V, respectively. For the quantitative analysis of the Fowler-Nordheim (F-N) type emission from a CNP triode emitter, we carried out 2dimensional numerical calculation of electrostatic potential using the finite element method. As it turned out, a radial variation of electric field was very important to account for the emission from a planar emitting layer. By assuming the graphitic work function of 5 eV for CNPs, we were able to extract a consistent set of F-N parameters, together with the radial position of emitting sites.

  • PDF

이방성 매질의 기판과 덮개층을 갖는 마이크로스트립 패치 안테나의 방사패턴 (Radiation Pattern in Rectangular Microstrip Patch Antenna with Anisotropy Substrates and Superstrate)

  • 윤중한;이화춘;곽경섭
    • 전기전자학회논문지
    • /
    • 제7권1호
    • /
    • pp.32-42
    • /
    • 2003
  • 본 논문에서는 이방성 매질의 덮개층과 기판을 갖는 사각 마이크로스트립 패치 안테나의 방사패턴을 full-wave approach와 모멘트 계산법을 이용하여 연구하였다. 이방성 매질내의 구성관계식을 통하여 제안된 구조에서의 파수영역 다이애딕 그린 함수를 유도하였으며 이 결과로부터 전계 적분 방정식을 수식화하였다. 갤러킨 모멘트법을 사용하여 전계 적분 방정식을 이산화 하여 전류밀도의 계수를 구한 후에 구좌표계의 원거리 전계는 고정 위상법(stationary phase method)을 이용하여 얻을 수 있다. 전사모의 실험 결과의 타당성을 검증하기 위해서 기존의 결과와 비교하여 일치된 결과를 얻었으며 이방성 덮개층의 두께 변화 그리고 기판과 덮개층의 이방성 비에 따른 방사패턴이 제시되고 분석되었다.

  • PDF

자장을 이용한 이온화율 증대형 삼극형 BARE에서 이온화율의 증대경향과 QMS를 이용한 이온의 에너지 분포 측정 (Measurement of Ion Energy Distribution using QMS & Ionization Enhancement by usign Magnetic Field in Triod BARE)

  • 김익현;주정훈;한봉희
    • 한국표면공학회지
    • /
    • 제24권3호
    • /
    • pp.119-124
    • /
    • 1991
  • Recently, the trend of research in hard coating is concentrate on developing the process of ionization rate under low operating pressure, to get the thin film with high adhesion and dense microstructures. In this study ionization rate enhancement type PVD process using permanent magnet is developed, which enhances the ionization rate by confining the plasma suppressing the wall loss of electron. By the result to investigate the characteristic of glow discharge, the ionization rate of this process is enhanced about twice as high as that of triod BARE process (about 26%), and more dense TiN microstructures are obtained in this process. Cylindrical ion energy analyzer is made and attached in front of a quadrupole mass filter for the analysis of the energy distribution of reactive gas and activated gas ions from the plasma zone. To analyze the operation mechanism of ion energy analyzer, computer simulation is performed by calculation the electric field environment using finite element method. By these analyses of ion energy distribution of outcoming ions from the plasma zone, it is found that magnetic field enhances ion kinetic energy as well as ionization rate. The other results of this study is that the foundation of feed-back system is constructed, which automatically control the partial pressure of reactive gas. In can be possible by recording the data of mass spectrum and ion energy analysis using A-D converter.

  • PDF

분기선로가 있는 3상 전력선로하의 전자파 자계 계산 (Calculation of Magnetic Fields under 3 Phase Power Lines with Branch Lines)

  • 강대하;이영식;김부규
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.110-119
    • /
    • 2009
  • 본 연구에서는 임의의 각도로 분기되어 있는 전력선로 근방의 자계를 유도하여 정식화 하였으며 이 공식을 이용함으로써 그 자계 계산을 쉽게 할 수 있다. 이 공식들은 분기선로가 있는 배전선로의 설계 시 검토자료로서 활용할 수 있을 것으로 생각된다. 예로서 자계요소에 관한 공식들을 분기선로가 있는 3상 배전선로 모델에 적용하여 메틀랩 프로그램에 의해 계산하였으며 그 결과를 제시하였다. 그 분석결과를 요약하면 다음과 같다. 합성자계는 분기각이 작고 관측점의 높이 z가 낮으면 전 y-축상에 걸쳐 By 요소가 지배적이다. 이 합성자계는 분기각 ${\alpha}=\frac{\pi}{2}$[rad]의 경우 Bx의 영향을 크게 받는다. 또한 이 합성자계는 전력선 높이와 같은 전선로 근방에서 Bz요소가 지배적이며 분기각이 ${\alpha}>\frac{\pi}{2}$[rad]의 경우에는 y축의 분기전선 위치에서 매우 큰 값을 나타낸다.

효율적 균일 방전을 위한 레이저 전극 형상 비교 (Comparison of laser electrodes for efficient uniform disharge)

  • 김동환;주홍;최상삼
    • 한국광학회지
    • /
    • 제3권2호
    • /
    • pp.133-136
    • /
    • 1992
  • 엑시머 레이저나 TEA $Co_2$ 레이저로응용되는 균일 방전을 위한 전극 형상 설계에 중됴한 k 값과 전극의 크기에 고려되는 최소 허용 전기장의 위치와의 관계를 Chnag 형상과 Ernst 형상에 대해 각각 계산, 비교하였다. 이 결과는 전극 형상 설계에 있어서 초기 k 값 설정에 도움표를 제공한다. 전극 표면에서 각각의 전기장 세기를 비교하여 Ernst 형상이 Chang형상보다 2배내지 3배 정도로 균일 전기장 분포가 넓게 설계될 수 있음을 보였다.

  • PDF

HVDC 해저케이블의 연속허용전류 계산에 관한 연구 (A Study on the Calculation of Allowable Continuous Current for HVDC Submarine Power Cables)

  • 임충환;박흥석;문채주
    • 한국전자통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.815-824
    • /
    • 2022
  • 해상풍력발전과 같은 간헐성 재생에너지원의 급격한 성장은 바다를 횡단하는 장거리의 전기에너지의 변환 필요성을 증가시키고 있다. 넓고 깊은 바다에 걸쳐서 장거리 대용량 전력송전을 위한 해법중의 하나는 HVDC 해저 전력케이블을 사용하는 것이다. 그러나 교류자계가 없는 직류전력 케이블의 다양한 해양조건을 갖는 연속허용전류와 관련한 표준이나 연구가 없다. 본 연구에서는 대표적인 두 종류의 해저케이블 모델과 남해안과 서해안 두 지역의 해양 요건을 가정하여 직류케이블의 연속허용전류를 모의하였다. 모의 결과를 보면 직류케이블의 연속허용전류는 해저 지반 깊이에 기반한 감소 구배 특성을 갖고 있는 것을 확인하였다.