• 제목/요약/키워드: Electric fan

검색결과 180건 처리시간 0.023초

전자식 엔진냉각제어 시스템을 위한 팬 클러치 특성 분석 (Analysis of fan clutch characteristics for electronic engine cooling control system)

  • 류혜연;김현희;정성민;고영호;이경창
    • 한국산업융합학회 논문집
    • /
    • 제21권5호
    • /
    • pp.241-246
    • /
    • 2018
  • The engine cooling system is a device that keeps the temperature of the engine room at a proper level by driving the cooling fan when the engine room temperature that occurs during driving is above a certain temperature. Recently, the vehicle cooling system has been changed to electronic system. Therefore, in this paper, we will analyze the clutch operation characteristics for designing a superior electronic fan clutch. For this purpose, an electronic fan clutch was designed and a test bed for performance evaluation was constructed and analyzed.

산업용 유량제어 송풍기 베인댐퍼 개발에 관한 연구 (A Study on Development of Vane Damper for Industry Flow Control Fan)

  • 이중섭;정인국;윤지훈;서정세;장성철
    • 한국생산제조학회지
    • /
    • 제21권1호
    • /
    • pp.137-143
    • /
    • 2012
  • In this study, it was conducted to design each components of vane damper for industrial flow control fan and the flow rates were analysed by experimental and numerical method. Through environmental test, it could be confirmed that the designed vane damper was appropriate. Also, almost identical results with test could be drawn from numerical method. Finally, flow rates of electric and pneumatic actuator were measured by test. As the results, difference of flow rate according to opening ratio was smaller in pneumatic actuator than that in electric actuator.

피치각 조정형 송풍-역풍 겸용 축류팬에서 배연용 피치각 선정을 위한 실험적 연구 (An Experimental Study on Selection Pitch Angle on backward flow of an Axial Fan with Adjustable Pitch Angle Blades)

  • 장택순;허진혁;문승재;이재헌
    • 플랜트 저널
    • /
    • 제5권1호
    • /
    • pp.45-50
    • /
    • 2009
  • In this study, the experimental study has carried out to select pitch angle on the backward flow in an axial fan that has adjustable pitch blades. With the change of pitch angle of axial fan with adjustable blade, air flow rate, pressure and air flow direction can be changed. Because of this merit, adjustable axial fan can be used in the backward flow. For the selection of the backward flow pitch angle, fan performance test method is selected by KS B 6311. Dynamic pressure, static pressure, electric current and voltage are measured in each pitch angles of axial fan that are $36^{\circ}$, $-16^{\circ}$, $-21^{\circ}$, $-26^{\circ}$, $-31^{\circ}$ and $-36^{\circ}$. In the result of test, fan performance curves at several pitch angle has been investigated. Finally, pitch angle of $-26^{\circ}$ has been selected to get largest flow rate at backward flow situation.

  • PDF

2단 축류팬과 엇회전식 축류팬의 공력 특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Two Stage and a Counter-Rotating Axial Flow Fan)

  • 조이상;조진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.541-547
    • /
    • 2000
  • Experiments were done for the comparison of performance and flow characteristics between a two stage axial flow fan and a counter-rotating axial flow fm. The fan performance curves were obtained by the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fan flow characteristics were measured using a five-hole probe by the non-nulling method. Each stage of the two stage axial flow fan used for the present study has an eight bladed rotor and thirteen stator blades. The front and the rear rotor of the counter-rotating axial flow fan have eight blades each and are driven by coaxial counter rotating shafts through a gear box located between the rear rotor and the electric motor. Both of the two axial fan configurations use identical rotor blades and the same operating conditions for the one-to-one comparison of the two. Performance characteristics of the two configurations were obtained and compared by varying the blade setting angles and axial gaps between the blade rows. The passage flow fields between the hub and tip of the fans were measured and analyzed for the particular operating conditions of peak efficiency, minimum and maximum pressure coefficients.

  • PDF

피치각 조정형 송풍-역풍 겸용 축류팬에서 배연용 피치각 선정을 위한 실험적 연구 (An Experimental Study on Selection Pitch Angle on backward flow of an Axial Fan with Adjustable Pitch Angle Blades)

  • 장택순;허진혁;문승재;이재헌;유호선;임윤철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.145-150
    • /
    • 2008
  • In this study, the experimental study has carried out to select pitch angle on the backward flow in an axial fan that has adjustable pitch blades. With the change of pitch angle of axial fan with adjustable blade, air flow rate, pressure and air flow direction can be changed. Because of this merit, adjustable axial fan can be used in the backward flow. For the selection of the backward flow pitch angle, fan performance test method is selected by KS B 6311. Dynamic pressure, static pressure, electric current and voltage are measured in each pitch angles of axial fan that are $36^{\circ}C$, $-16^{\circ}C$, $-21^{\circ}C$, $-26^{\circ}C$, $-31^{\circ}C$ and $-36^{\circ}C$. In the result of test, fan performance curves at several pitch angle has been investigated. Finally, pitch angle of $-26^{\circ}C$ has been selected to get largest flow rate at backward flow situation.

  • PDF

횡류팬 내부의 유동해석 (Flow Analyses in a Cross-Flow Fan)

  • 이형건;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.65-70
    • /
    • 2002
  • Cross-Flow Fan(CFF) are widely used lot industrial equipments and household electric appliances. A design method for CFFs, however, has not been well established because of the complexity of the internal flow. Numerical analysis was performed by using STAR-CD. In this study present the internal flow of CFF, which has varies pin number, and their flowrate were compared

  • PDF

업체탐방 - 삼현CNS(주) (SAMHYUN)

  • 손영선
    • 전기기술인
    • /
    • 통권333호
    • /
    • pp.48-49
    • /
    • 2010
  • 삼현CNS(주)는 1997년 5월 설립되어 FAN TRAY, 정류기 개발 기술을 기본으로 다양한 기술 집약형 특수용도의 전원공급부에 필요한 안정화 장치와 서지보호기를 공급해 한국전력, 수자원공사, 발전회사, KT 등으로부터 높은 기술력과 제품력을 인정받고 있다.

  • PDF

전기오븐의 강제대류 열전달 특성 연구 (A numerical analysis of forced convection heat transfer in an electric oven)

  • 노선종;조성호;김형식;곽동성
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.124-128
    • /
    • 2011
  • The heat transfer rate in an oven is very important for the quality of cooking food. For a robust performance design in an electric oven, forced convection has been used rather than natural convection, in bake and convection mode. Forced convection heat trans for in a vented electric oven has been numerically evaluated using the commercial software FLUENT. CFD modeling of the electric oven involves three-dimensional, steady state, MRF fan model and DO radiation model. In this study, the electric oven cavity and fan modules are not simplified. Other research shows that the boundary condition can often lead to non-physical solutions, such as reverse flaw at the top vent. To remove this non-physical solution, control volume has been expanded at the nearby vent. This numerical analysis has been performed with dedicated experimental support. The results show that there is less than a 2.2% difference between the simulation and experimental data for the temperature profile of food. From this research we can use this oven simulation technique to make a better convection system in an electric oven.

  • PDF

도심항공 모빌리티(UAM)를 위한 틸트 덕티드 팬 형 eVTOL의 초기 사이징 (Initial Sizing of a Tilt Ducted Fan Type eVTOL for Urban Air Mobility)

  • 이상곤;고보성;안성호;황호연
    • 한국항공운항학회지
    • /
    • 제29권3호
    • /
    • pp.52-65
    • /
    • 2021
  • A large amount of time and cost is consumed due to congestions caused by an increasing number of cars which results in a lot of emissions. To overcome these problems, a new electric vertical takeoff and landing (eVTOL) aircraft is being considered. Since vertical take off and landing without a separate runway is realized and electricity is used as a power source, it could solve the saturated ground traffic congestions without emissions. In this paper, the initial sizing was performed based on the Nexus 6HX of Belltextron which is a tilt-ducted fan type. In this study, the electric propulsion system that only uses battery was implemented instead of current Nexus 6HX hybrid electric propulsion. Aerodynamic analyses were performed using OpenVSP and XFLR5. Power-to-weight ratio, wing loading, estimated weight were calculated with these analyses.

Influence of Blade Row Distance on Performance and Flow Condition of Contra-Rotating Small-Sized Axial Fan

  • Shigemitsu, Toru;Fukutomi, Junichiro;Shimizu, Hiroki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제5권4호
    • /
    • pp.161-167
    • /
    • 2012
  • Small-sized axial fans are used as air coolers for electric equipment. There is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices. Therefore, higher rotational speed design is conducted, although, it causes the deterioration of the efficiency and the increase of noise. Then, the adoption of contra-rotating rotors for small-sized fans is proposed for the improvement of the performance. In the case of contra-rotating rotors, blade row distance between the front and the rear rotors influences on the performance and the noise. Therefore, it is important to clarify the optimum blade row distance between front and rear rotors. The performance curves of the contra-rotating small-sized axial fan under the condition of different blade row distances are shown and the blade row interaction between the front and the rear rotors are discussed by the numerical results. Furthermore, the optimum blade row distance of the contra-rotating small-sized axial fan is considered.