• Title/Summary/Keyword: Electric fan

Search Result 180, Processing Time 0.022 seconds

A Study on Physical Characteristics and Plastics Recycling of Used Small Household Appliances (폐소형가전의 물리적 성상 분석 및 플라스틱 재활용에 관한 연구)

  • Choi, Woo Zin;Park, Eun Kyu;Kang, Seok Hwan;Jung, Bam Bit;Kim, Soo Kyung
    • Resources Recycling
    • /
    • v.25 no.1
    • /
    • pp.31-39
    • /
    • 2016
  • Small household appliances such as electric rice cooker, a vacuum cleaner, an electric fan, etc. are diverse and complex due to the materials and components and waste streams from the manufacturing processes. In the present study, physical characterization of small e-wastes was analyzed on major items including electric rice cooker after manual dismantling. Small household appliances is an important potential source of waste plastic, however, recycling plastics from small e-waste is still unusual. The present communication gives results of separation processes on black plastics and the limitations of these sorting processes in used small household appliances.

Analysis of Current Situation for Environmental Facilities and Disinfection in Hanwoo Farms (한우농가의 환경시설관리 및 방역실태 분석)

  • Kim, Gye-Woong;Kim, Kon-Joong
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.61-70
    • /
    • 2011
  • This survey was conducted to investigate the current situation of ground condition of barn, moisture condition, feeding facilities, disinfection tool, etc. The data from a total of 305 farms were collected and analysed for establishment of managemental target in Hanwoo farm. The ground condition of barn was evaluated as a result of "moderate level" (46.4%). The moisture removal on the ground was conducted with the aid of electric fan (36.4%). The natural wind and sunlight should be used gradually for economic effect in farm. The exchange of floor straw was mostly conducted to remove the bad smell of barn (33.7%). 37.0% of farms had no the electric fan in internal barn, this instrument must be installed for control of body temperature and internal moisture in the future. Most of feeding facilities were operated by hand(88.2%). Modern farms should be installed with automatic feeding system. Farmer's skill of management was evaluated as a "2.80" of 5 points. Accordingly, farmers should be trained with high level of technical competitive skill. In conclusion, Hanwoo farms should be promoted and improved for enhancement of income through introduction to scientifically modern feeding skill.

Automatic Control System in Room using Zigbee Sensor and Microcontroller Chip (무선센서와 마이크로 컨트롤러를 이용한 실내 환경 자동 제어 시스템)

  • Jean, Byoung-Chan;Choi, Gyoo-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.5
    • /
    • pp.147-154
    • /
    • 2009
  • Lately, superhigh speed network infra is developing with the fast speed, is evolved by step that existent appliances are digitalised and appliances are become remote control by being gear to network. Also, gearing in Home network and superhigh speed network infra, control appliances in Internet and research that do monitering is proceed. Therefore, describe about indoor environment automatic control system that use Wireless sensor and Microcontroler in this paper. Because using that electric power, Zigbee sensor and Wireless module, embodied system that measured in the room temperature and use ATmega128 Microcontroler and use each device (temperature, illumination, humidity) back in house and control humidifier, electric fan etc. Can use variously in Home network field by this Wireless sensor and Microcontroler base, and also can apply variously to several industry fields as well as Home network field.

  • PDF

Cathodic Reduction of Cu2+ and Electric Power Generation Using a Microbial Fuel Cell

  • Wang, Zejie;Lim, Bong-Su;Lu, Hui;Fan, Juan;Choi, Chan-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.2025-2030
    • /
    • 2010
  • When $Cu^{2+}$ was used as an electron acceptor, removal of $Cu^{2+}$ was achieved from the synthesized wastewater (SW) in the cathode compartment of a microbial fuel cell (MFC). By addition of $KNO_3$, the different initial pH of the SW showed no effect on the removal efficiency of $Cu^{2+}$. For $Cu^{2+}$ concentration of 50 mg/L the removal efficiencies were found to be 99.82%, 99.95%, 99.58%, and 99.97% for the $KNO_3$ concentrations of 0, 50, 100 and 200 mM, and to be 99.4%, 99.9%, 99.7%, and 99.7% for pH values of 2, 3, 4, and 5, respectively. More than 99% $Cu^{2+}$ was removed for the $Cu^{2+}$ concentrations of 10, 50, and 100 mg/L, while only 60.1% of $Cu^{2+}$ was removed for the initial concentration of 200 mg/L (pH 3). The maximum power density was affected by both $KNO_3$ concentration and initial concentration of $Cu^{2+}$. It was increased by a factor of 1.5 (from 96.2 to 143.6 mW/$m^2$) when the $KNO_3$ concentration was increased from 0 to 200 mM (50 mg/L $Cu^{2+}$), and by a factor of 2.7 (from 118 to 319 mW/$m^2$) when $Cu^{2+}$ concentration was increased from 10 to 200 mg/L (pH 3).

Improving Fuel Efficiency of a Hybrid Excavator (하이브리드 굴삭기 연비 개선 연구)

  • Cho, Sungwoo;Yoo, Seungjin;Park, Cheol-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.2
    • /
    • pp.211-217
    • /
    • 2015
  • Emission gas regulations and constantly increasing fuel costs call for the worldwide use of environmentally friendly and energy-efficient machines in industry. To meet these requirements, a hybrid excavator prototype has been developed that incorporates an electric swing motor, engine assist motor, and ultra-capacitor module into a conventional hydraulic excavator of the 22-ton class. This paper mainly describes a few techniques to optimize its energy efficiency. These include 1) controlling the engine speed in proportion to the load torque, 2) controlling the pump displacement when driving the electric swing system, 3) managing the ultra-capacitor voltage to minimize the electrical energy loss, and 4) reducing the cooling fan speed to improve the energy efficiency of the system.

Study Growth Environmental Monitoring and Controlling Platform for Hydroponic (양액재배를 위한 생육환경 모니터링 및 제어 플랫폼에 관한 연구)

  • Yeon, In-won;Lee, Won-cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.9
    • /
    • pp.1132-1140
    • /
    • 2016
  • According to global trend, despite the overall scale of agricultural industry has been downsized, agriculture accommodating cutting-edge ICT technologies has been proliferated, and various timely-issued relevant researches have been on progress to deploy the future food cultivation. In this paper, we propose an effective nutrient management system with web-based monitoring with functionality of controlling temperature, humidity, pH (hydrogen ion), EC (Electric Conductivity), LED and cooling fan to maintain the hydroponic nurturing environment being optimal. In this paper, in order the arduino hardware and java software are employed to control the nurturing environment automatically in optimal fashion. In proposed system, due to the usage of WiFi router with the socket communication and DB-assisted Web server with proper interfaces, it allows to facilitate the management to keep monitoring and controling overall hydroponic nurturing environment. Since the proposed Web-based management system provides the superior reliability, the short nurturing period and the robustness to the pest by controlling LED emitting color rather than conventional system, so it can be applied and appropriate for in-house vegetable factory overcoming limitation of time and location.

Characteristics of Quasi-MFISFET Device Considering Leakage Current (누설전류를 고려한 Quasi-MFISFET 소자의 특성)

  • Chung, Yeun-Gun;Joung, Yang-Hee;Kang, Seong-Jun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1717-1723
    • /
    • 2007
  • In this study , quasi-MFISFET (Metal-Ferroelectric-Insulator-Semiconductor FET) devices are fabricated using PLZT(10/30/70), PLT(10), PZT(30/70) thin film and their drain current properties are investigated. It is found that the drain current of quasi-MFISFET is directly influenced by the polarization strength of ferroelectric thin fan. Also, when the gate voltages are ${\pm}5\;and\;{\pm}10V$, the memory windows are 0.5 and 1.3V, respectively. It means that the memory window is changed with the variation of coercive voltage generated by the voltage applied on ferroelectric thin film. The electric field and the leakage current with time delay of PLZT(10/30/70) thin lam are measured to investigate the retention property of MFISFET device. Some material parameters such as current density constant, $J_{ETO}$, electric field dependent factor K and time dependent factor m are obtained. The variation of charge density with time is quantitatively analyzed by using the material parameters.

Effects of Cooking Method on Physicochemical Characteristics and Qualities of Hamburger Patties (가열처리방법이 햄버거 패티의 이화학적 특성과 품질에 미치는 영향)

  • Lee Chan-Ho;Ha Jong-Soo;Jeong Jong-Yon;Lee Eui-Soo;Choi Ji-Hun;Choi Yun-Sang;Kim Jin-Man;Kim Cheon-Jei
    • Food Science of Animal Resources
    • /
    • v.25 no.2
    • /
    • pp.149-155
    • /
    • 2005
  • This study was conducted to investigate effects of cooking method on physicochemical characteristics and qualities of hamburger patties processed with ground pork/beef meat $(20\%\;fat)$. Hamburger patties were cooked by electric griddling, fan frying, microwave, conventional cooking, and charbroiling. Cooking rates were affected by cooking methods, had the highest in patties cooked in microwave oven. Hamburger patties by microwaving were also higher moisture content, but were lower protein and fat content compared to other methods. Electric griddling and microwaving were higher cooking yield, lower diameter changes in patties than other methods, but pan frying showed the opposite effects. Higher values of hardness and brittleness in pan frying than those of other methods were showed, but pan frying had the highest overall acceptability in sensory evaluations.

The Performance Assessment Study of Solar Energy Cogeneration panel for Building Integrated System (건물통합을 위한 태양에너지 cogeneration panel 특성 분석 연구)

  • Kim, Yong-Hwan;Kang, Eun-Chul;Hyun, Myung-Taek;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.35-42
    • /
    • 2006
  • Solar Thermal-Electric Integrated system can be used to generate heat and electricity simultaneously and can improve indoor all qualify. So, it can save heating and electricity cost as it operates at relatively lower temperatures. In this study, one pv module was fixed on a normal wall and a pv module was mounted on a solarwall. And a ventilation fan in the solar energy cogeneration panel was operated from 12:00 to 17:00 hours. Experimental results are recorded and anaysized. The comparison of results show that the temperature of PV on solar energy cogeneration panel was decreased by $7{\sim}9^{\circ}C$ and the electrical output was improved by $2{\sim}3W$ compared with a PV system without solarwall.

Development of a Drain-Type Electronic Dehumidifier Using Thermoelectric Element (열전소자를 이용한 배수형 전자제습기 개발)

  • Kang, Deok-Hong;Kim, Seong-Hwan;Kim, Ki-Hong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3524-3528
    • /
    • 2007
  • In this study, the Peltier effect was applied to eliminate moistures in the air enclosed by a cabinet. We have developed the new electronic dehumidifier which has a new function of automatically evaporating the condensed water inner cabinet into the outside air. To obtain this function, the processes of dehumidification is that it condensed the moistures on the cold side heat sink and drained it into the hot side heat sink by the both gravitational and capillary forces and the droplets on the hot side heat sink surface was evaporated into the air outside the cabinet by the heat conducted through the hot side heat sink surface and the forced heat convection through the fan for cooling hot side heat sink. Compared to existing electronic dehumidifiers, this manufactured one showed a good performance that the electric power consumption for the same dehumidifying quantity was reduced by 50% compared with that of existing ones.

  • PDF