• 제목/요약/키워드: Electric contact type switch

검색결과 13건 처리시간 0.027초

저압직류용 하이브리드 차단기 (Hybrid LVDC Circuit Breakers)

  • 김효성
    • 전력전자학회논문지
    • /
    • 제27권6호
    • /
    • pp.489-497
    • /
    • 2022
  • This work investigates the commutation characteristics of the current flowing through an electrical-contact-type switch to the semiconductor switch branch during the breaking operation of hybrid DC switchgear. A simple, reliable, low-cost natural commutation method is proposed, and the current commutation characteristics are analyzed in accordance with the conduction voltage drop of the semiconductor switch branch through experiments. A prototype 400 V/10 A class natural commutation type hybrid DC switchgear is set up. Its performance is verified, and its characteristics are analyzed.

A Modeling of Impact Dynamics and its Application to Impact Force Prediction

  • Ahn Kil-Young;Ryu Bong-Jo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권spc1호
    • /
    • pp.422-428
    • /
    • 2005
  • In this paper, the contact force between two colliding bodies is modeled by using Hertz's force-displacement law and nonlinear damping function. In order to verify the appropriateness of the proposed contact force model, the drop type impact test is carried out for different impact velocities and different materials of the impacting body, such as rubber, plastic and steel. In the drop type impact experiment, six photo interrupters in series close to the collision location are installed to measure the velocity before impact more accurately. The characteristics of contact force model are investigated through experiments. The parameters of the contact force model are estimated using the optimization technique. Finally the estimated parameters are used to predict the impact force between two colliding bodies in opening action of the magnetic contactor, a kind of switch mechanism for switching electric circuits.

소음과 불꽃을 제거한 단상유도전동기의 아날로그식 기동기 설계 (Analogue type Starter of Single Phase Induction Motor Removing Noise and Arc)

  • 박수강;조금배;백형래;임양수;이성길;임종연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.654-656
    • /
    • 2001
  • This research used triac that is semi-conductor that act to static contact to overcome happened shortcoming been using mechanical centrifugal force switch usually Detect starting current of single phase induction motor and decided moving time. Therefore, could improve life of switch semipermanently. Also, wish to reduced impact that electric motor suffers at the starting moment and do stable starting which there is no life improvement and noise of electric motor itself, arc.

  • PDF

노내 핵계측 계통 구동기기의 전자식 한계스위치 개발 (Development of Electronic Limit Switch for the Drive Unit of Incore Detector System Application)

  • 박종범;양승권;이상효
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.1-7
    • /
    • 2000
  • 본 논문에서 원전의 핵연료 다발의 중섬자속을 측정할 수 있는 노내중성지속 감시계통의 구동모터를 제어하기 위한 스위치의 오동작 원인 분석 및 이 문제를 해결하기 위한 방안을 제시하고자 한다. 노내중성자속 감시계동은 검출기 안내관을 통해 검출기가 노심으로 삽입되거나 인출될 경우 접점선호를 발생하는 기계식 스위치레버를 장착하고 있다. 그러나 기계적인 열화나 환경적인 요인에 의해 기계식 스위치레버의 특성이 점점 변화되어 마침내 잘못된 접점신호를 발생하게 된다. 그러므로 아들 문제 해결을 위해 기계식 스위지 대선 전자식 스위치를 검출기 안내관 밖에 배치하였고, 공진효과를 이용하여 점점신호를 발생하는 회로개선과 소음 및 전기적 방해를 방지하기 위한 콘데서를 전자회로 전원 입력측에 설치하였다. 이러한 개선을 완료한 후, 여러 조건하에서 이 향상된 스위치 제어회로를 반복적으로 시험하였는데, 결국 이를 통해 원하는 접점신호를 얻게되었을 뿐 아니라 발전소 정상운전 중에 관련시스템의 주기시험을 통해서도 검출기 접점 오동작 신호가 발생되지 않음울 확인할 수 있게 되었다.

  • PDF

전기분전반용 블록형 부스 바의 구조 설계 연구 (The Structural Design of the Bus-bar block type of electrical switch boards)

  • 권영민;황찬규;김근호;한희
    • 한국산학기술학회논문지
    • /
    • 제17권2호
    • /
    • pp.378-385
    • /
    • 2016
  • 전기 분 배전반의 내부 회로 인 부스 바는 충전부의 노출로 인해 전기 사고의 원인이 되며 이로 인한 감전 사고와 단락 사고가 발생된다. 또한 동물 및 이물질 침투로 인한 전기 화재 사고가 발생되는 원인이 되기도 한다. 또한 확장이 불가능한 구조로 무리하게 연결하여 사용하므로 접촉 저항 증가 발생으로 과열 사고를 유발시키기도 하며, 절단과 절곡 등의 제조 공정상의 어려움을 가지고 있기 때문에 주문생산방식을 택할 수밖에 없는 현실이며, 긴급전기 사고 발생시 복구하는데 지연되는 원인이 되기도 한다. 본 논문에서는 이와 같은 문제점을 개선하기 위해서 분 배전반의 모선을 절단하여 개별 블록으로 절연 난연 케이스와 격벽 구조화로 안전성을 높여 모듈 블록화 하였으며, 확장성과 유연성을 구현하였으며, 쉽게 확장이 가능한 구조이며, 또한 쉽게 분 배전반을 조립할 수 있다는 것이며, 이와 같이 전기적 위험 요소를 제거한 전기 분 배전반의 내부 구조는 블록형 부스 바 구조를 가지고 메인차단기와 분기차단기간의 회로 형성 구현 방식의 분 배전반를 제안하고 공인시험기관의 시험을 통해 그 유용성을 입증 하였다.

4-WD 동력전환장치의 변속 모터 구동부 최적화에 관한 연구 (A Study on the Shift Motor Driving System Optimization of 4-WD Power Transformation Device)

  • 염광욱;함성훈;오세훈
    • 한국정밀공학회지
    • /
    • 제30권11호
    • /
    • pp.1187-1192
    • /
    • 2013
  • In the case of 4 wheel drive (4-WD) type car, power switching occurs to 4-WD by operating lever or switch that operates power switching device attached in transfer case which can operate motor by electric signal. So if the RPM of motor is high, power switching will not exactly occur and can cause damage to gear in transfer case according to circumstances. So in this study, we applied 2 level of planet gear type motor spindle of motor drive part of a power train. And conducted decelerating to increase torque to switch power safe and accurately. Also, we researched efficiency of gear by designing reduction gear ratio and gear type and by calculating contact stress and bending strength. Based on researched content, we made drive head of power switching device and a reduction module which uses type that uses motor spindle as sun gear and ring gear as cover.

탠덤형 자석 소호기를 사용한 760V급 직류 개폐기의 차단 특성 (760 V-Class DC Switch Breaking Characteristics Using Tandem Type Magnet Extinguisher)

  • 김효성
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.175-179
    • /
    • 2022
  • Magnetic arc extinguishing technology is effective as an extinguishing device for low-voltage direct current (DC) circuit breakers with a resistive load of ≤4 kW. The separation distance between the magnet and the electrical contact must be shortened to increase the magnetic arc extinguishing force. However, if the magnet is installed too close to the electrical contact points, the magnet is exposed to high temperatures due to the arc current generated when the load current is cut off and the magnetism is lost. To solve this problem, the effective magnetic flux density at the electrical contact can be maintained high by placing the arc extinguishing magnet in a tandem structure with the electrical contact point between them, and the proper separation distance between the contact points and the magnet can be maintained. In addition, an electric arc extinguishing technology that emits arc energy using a series circuit of diode and resistor is used to suppress the continuous arc voltage generated by the inductive load. For the proposed circuit breaker, the breaking characteristics are analyzed through the breaking test for the DC load of the 760 V level, the load power of 4 kW, and the time constant of 5 ms, and an appropriate arc extinguishing design guideline is proposed.

가연물 접촉에 따른 전기히터의 화재위험성에 관한 실험적 연구 (An Experimental Study on the Fire Risk of Electric Heaters According to Contact of Flammable Materials)

  • 이성룡
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.63-71
    • /
    • 2011
  • 본 연구에서는 대표적인 계절용기기인 전기히터에 대하여 발화위험성을 평가하였다. 실험에는 2종류의 전기히터가 사용되었다. 전기히터 가동 시 히터 표면 및 주변의 온도변화를 측정하였으며, 내부 비파괴검사를 통하여 전기히터 내부구조를 파악하였다. 전기히터 화재원인 중 가장 높은 비율을 차지하는 가연물 근접방치에 의한 화재위험성을 평가하였다. 또한 전도 안전스위치 오작동에 의한 발화위험성을 평가하였다. 정상작동 시 전기히터 발열제 주위에서 온도가 $80^{\circ}C$ 이하로 유지되었다. 전기히터 가동 중 가연물 낙하 등으로 인하여 히터를 덮거나 안전장치(전도안전스위치, 과열방지장치)의 오작동 등에 의해 발화위험성이 상존하고 있다.

자동변속기장착 차량의 Shift-By-Wire 시스템 개발 (Development of Shift-By-Wire System for an Automatic Transmission Equipped Vehicle)

  • 김정윤;임충혁;임원식
    • 한국자동차공학회논문집
    • /
    • 제15권4호
    • /
    • pp.41-46
    • /
    • 2007
  • This article deals with the design and prototyping of Shift-By-Wire system for an automatic transmission equipped vehicle. In order to manipulate the shifting action electronically, Shift-By-Wire system consists of an electronic shift lever, an electric shift actuator and position sensors. The shift lever is designed to transform the driver's shifting command into an electric signal; it includes the position sensor using non-contact type hall sensor and an additional shifting switch acting as Tip-tronic. For the design of an electric shifting actuator, we investigated the stroke angles and shifting efforts of the manual control lever in each shifting section. And the position sensor of the shifting actuator is designed by using a potentiometer with an optical encoder. Finally the prototype of Shift-By-Wire system was built in a conventional 2.4L class SUV vehicle, and we performed road tests in order to verify its performance.

전기자동차용 2차전지를 위한 스마트 ICT형 전자식 외부 단락시험기 개발 (Development of Smart ICT-Type Electronic External Short Circuit Tester for Secondary Batteries for Electric Vehicles)

  • 정태욱;신병철
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.333-340
    • /
    • 2022
  • Recently, the use of large-capacity secondary batteries for electric vehicles is rapidly increasing, and accordingly, the demand for technologies and equipment for battery reliability evaluation is increasing significantly. The existing short circuit test equipment for evaluating the stability of the existing secondary battery consists of relays, MCs, and switches, so when a large current is energized during a short circuit, contact fusion failures occur frequently, resulting in high equipment maintenance and repair costs. There was a disadvantage that repeated testing was impossible. In this paper, we developed an electronic short circuit test device that realizes stable switching operation when a large-capacity power semiconductor switch is energized with a large current, and applied smart ICT technology to this electronic short circuit stability test system to achieve high speed and high precision through communication with the master. It is expected that the inspection history management system based on data measurement, database format and user interface will be utilized as essential inspection process equipment.