• Title/Summary/Keyword: Electric apparatus

Search Result 321, Processing Time 0.028 seconds

The Development of a Steering Control Apparatus for the Two Wheel Driving Electric Vehicles (2륜구동 전기차량용 회전 제어 장치 개발)

  • Lim, Dong-gyun;Shon, Min-ho;Choi, Jung-keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1115-1118
    • /
    • 2015
  • Two wheel type electric vehicles driving with the electric motors for guard are used increasingly at the airport and harbor place to move between narrow indoors. This type two wheel electric vehicles are powerd by batteries and using the steering control apparatus including multi sensors and handle operating device for forward and backward, rotating moving. At this research, we design sensor interfacing electronic control system use only the center of foot balance without the handle type steering apparatus. This design is for safety of drivers at one's cornering.

  • PDF

More Reliable Length Composition And Biomass Of EEL Population In The Lagoons Of Arcachon Bay

  • Lee, Tae-Won
    • 한국해양학회지
    • /
    • v.15 no.2
    • /
    • pp.108-111
    • /
    • 1980
  • The sampling was made by a kind of trap nets and an electric fishing apparatus in the lagoons of Arcachon Bay. Length frequency distributions obtained by two gears are combined to propose more reliable length composition of the population. The biomass was estimated by the capture and recapture method in a limited area with electric fishing apparatus, and it was redressed based on the corrected length composition. It showed approximately 638kg/ha in the deeper parts of the lagoons. It suggests that the lagoons of Arcachon Bay contain relatively high density of eels.

  • PDF

An Apparatus for Unbinding the Rope in the Auto Cleaning Apparatus of a Pillar (강관파일 자동 청소장치에서의 로프 풀림 장치)

  • Rhee Hyoung-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.5
    • /
    • pp.438-441
    • /
    • 2004
  • In this paper, an apparatus for unbinding the rope is studied to solve continuous work of the auto cleaning apparatus of a pillar. During operation of the auto cleaning apparatus of a pillar, in order to not swing the apparatus is down by it's weight according as electric motor velocity. We focus on the design and the implementation to upgrade the auto cleaning apparatus of a pillar that had been implemented.

  • PDF

A Study on Auxiliary Control Safety Apparatus for RCD Trip on Electric Arc and Spark Disasters - Using by Power Semiconductor Switching Device - (아크 및 스파크 재해에 대한 누전차단기 트립을 위한 보조제어 전기안전장치에 관한 연구 - 전력용 반도체 스위칭 소자 적용 및 응용 -)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.71-76
    • /
    • 2006
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device(RCD) of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms](KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this paper is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

The Fire Hazard of Screwed Electric Contacts Due to Mechanical Vibration at Low Voltage Equipment

  • Choi, Chung-Seog;Kim, Young-Seok;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.18-23
    • /
    • 2005
  • There are many electrical connections in the electric apparatus and most fires due to a fault contact result from a failure or misuse of electric apparatus and installation. The fault contact happens between electrical connections by the loose and the mechanical vibration. In this paper, we have investigated thermal and electrical properties of screwed electric contacts due to the mechanical vibration. The exciter was connected to a signal generator and power amplifier that provided the vibration frequency and amplitude. The vibration, temperature and voltage data were sent to a data acquisition system (DAQ). In the case that fault contact took place, the arc happened between the screwed electric contact and electric wire, heat due to the arc was transmitted to the adjacent insulators, for which the oxide could be generated more. In addition, a spark was generated and the insulator began to melt. Thus, the possibility of electrical fire became the highest in this case. Finally, when the fault contact takes place due to vibration, the hazard of an electric accident is very high.

Design and Performance Test of Plate Type ER-Valve (평판형 ER-Valve의 제작 및 성능실험)

  • 장성철;염만오
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.29-35
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-valves are measured with varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. If we allow the same electric field in the ER-Valve, we came to how that the pressure drop is effected by the electrode length and electrode width. When the strength of the electric field increased, the pressure drop happened big and the flow rate decreased.

Magnetic Field annealing apparatus for Clamped Amorphous Transformer Core (주상 변압기용 비정질 코어의 자장인가 코일 제작)

  • Song, Jae-Sung;Jeong, Soon-Jong;Kim, Ki-Uk;Kim, Byung-Geol;Hwang, See-Dole;Jeong, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.193-195
    • /
    • 1996
  • In amorphous transformer core, magnetic field annealing is required for inducing uniaxial magnetic anisotropy to circular direction of the core. Generally annealing temperature is about foot, so insulator using in solenoid bed must have a high temperature stability, mechanical strength and good machinability. In this study, we made the magnetic field annealing apparatus using insulators, conductors, connectors and power supply. And then tested the apparatus in annealing process of 50 kVA amorphous transformers.

  • PDF

Effects of Kigong Theraphy in Cocentration of Catecholamines and Cortisol and some Tests on Testing-Stressed (기공외기요법(氣功外氣療法)의 항(抗) 스트레스 효과(效果) 연구(硏究))

  • Kim Ki-Ok
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.1 no.1
    • /
    • pp.95-109
    • /
    • 1996
  • To investigate anti-stress effects of Manual Kigong, Manual-Apparatus Combined Kikong, and Systemic Kigong, this experiments were performed changing of plasma catecholaminess and serum cortisol measured. Also using D.I.T.I(Digital Infrared Thermongraphy Imaging), Pulse Analyzer, Electric Current on Neurometer, and Digital Flicker on Testing-Stressed. And following results were abtained. 1) Menual-Appartus Combined Kikong decreased significantly increasing concentration of plasma epinephrine and norepinephrine level in Testing-stressed. 2) Manual Kigong decreased increasing concentration of serum cortisol level in Testing-stressed. 3) Manual Kigong and Manual-Aparatues Combined Kikong increased decreasing thermomerty on the palm's center caused Testing-stressed. 4) All of three treats are small change in SET(Systolic Ejection Time) by Pulse Analyzer caused Testing-stressed. 5) More changes of Electric Current on the Neurometer Diagnosis caused Testing-stressed are as followed. Manual-Apparatus Combined Kikong >Systemic Kigong >Manual Kigong From the results, it may be concluded that Manual-Apparatus Combined Kikong Theraphy having more anti-stress effects than Manual Theraphy. Systemic Kigong Therapy.

A Study on Development of Over-load Fault Prevention Apparatus using Distribution Line Voltage (배전선로 선로전압을 이용한 과부하 사고 예방장치 개발에 관한 연구)

  • Kwak, D.K.;Park, D.H.;Park, Y.J.;Jung, D.Y.;Kim, D.K.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.617-618
    • /
    • 2012
  • Recently as the inactive response characteristics of the existing RCD(Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is proposed a prevention apparatus using neutral line voltage and semiconductor switching devices for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The proposed prevention apparatus confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker(RCD) through various operation performance analysis.

  • PDF