• 제목/요약/키워드: Electric apparatus

검색결과 321건 처리시간 0.026초

적외선 열화상 카메라를 이용한 수전설비 온도분포해석 (The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System)

  • 정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

신개발 접지장치의 성능평가시스템에 관한 연구 (A study on the system to evaluate the performance of novel ground apparatus)

  • 박상만;장상옥;박창호;강문호;최종기;이문석;최하옥;이용한;황광수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2666-2668
    • /
    • 2003
  • The most widely employed grounding apparatus in distribution systems is a driven rod. But this method has some difficulties to get a specified ground resistivity in cities or islands. Recently, the new ground apparatus are proposed. This paper describes the research which relates with the system to evaluate the performance of novel grounding apparatus.

  • PDF

국내 평가 가이드라인 제시를 위한 전기식 온구기의 열특성에 관한 연구 (Study on the Thermal Properties of Electric Moxibustion Apparatus for Presenting Assessment Guideline in Korea)

  • 이승호;강중원;남동우;김은정;이혜정;김갑성;이재동
    • Journal of Acupuncture Research
    • /
    • 제26권6호
    • /
    • pp.31-39
    • /
    • 2009
  • Objectives : To characterize the thermal properties of several Korean electric moxibustion apparatus and to suggest methods for improving their quality for related industry as well as the welfare of Korean. Methods : We reviewed previous literatures on traditional moxibustion to find necessary factors for electric moxibustion apparatus. We measured the thermal characteristics of electric moxibustion apparatus commercially available by using an automatic temperature acquisition system in a controlled environment. Uniformity and heat loss of the apparatus were also analysed. We followed the user's manuals of apparatus provided by manufacturers. Results : Temperature control of all apparatus could not be achieved by automatic manners. Most of them were dependent on user's discretion. Maximum temperatures obtained were barely in the therapeutic temperature of $40-45^{\circ}C$. Unnecessary heating of moxibustion parts was detected. Chemicals from moxa were not properly delivered to the human skin. Conclusions : Temperature control of all apparatus needs to be improved in terms of temperature setting, retention time and maximum temperature. Design should be altered to utilize pharmacological effects from moxa to obtain its maximum efficacy. User's manuals should be revised for its clarity.

  • PDF

Glass beads 제조에 관하여 (The Preparation of Glass Beads)

  • 김진일
    • 대한화학회지
    • /
    • 제17권3호
    • /
    • pp.198-206
    • /
    • 1973
  • 이형제와 유리분말의 혼합물을 회전시킬 수 있는 원형전기로 장치(장치 1), 유리분말을 자유낙하 시킬 수 있는 관형 전기로 장치 (장치 2) 및 유리분말을 propane gas의 화염과 함께 분사시킬수 있는 관형장치 (장치 3)를 사용하여 glass beads를 제조하였다. 사용한 기재는 한국산 sodium silicates glass 1,2, boro silicates glass 및 lead silicates glass 이며 cullet의 크기는 60mesh-300mesh이다. P.G.를 기재로 하여 이들 장치에 의하여 glass beads를 제조할 경우, 장치 1의 최적온도는 880$^{\circ}C$이고 장치 2의 최적온도는 980$^{\circ}C$이며 장치 3의 최적온도는 1100$^{\circ}C$이었다. 그렇지만 처리시간과 응착률 등으로 보아 장치 3의 방법이 가장 효율적이었다.

  • PDF

ECG 생체신호 측정을 위한 실용적 U-헬스케어 의복개발 (Development of the Practical Garment Apparatus to Measure Vital Sign of ECG for U-Health Care)

  • 박혜준;홍경희;김승환;신승철
    • 한국의류학회지
    • /
    • 제31권2호
    • /
    • pp.292-299
    • /
    • 2007
  • Development of portable device measuring the vital sign continuously with no limit of time and space is absolutely prerequisite for the U-health care that grafts the ubiquitous concept into medical system. Accordingly, it requires to develop a garment style apparatus for measuring vital-sign that is easy to wear on for a long time period. This study suggests a method to improve the insulation of electric cable and the skin adhesion of electrode by integrating the electric conductive material to garment, in order to develop a garment apparatus for measuring ECG for U-health care. Results of the research are as follows; In order to provide the adjacent conductive yarns with insulation, braid with narrow woven end was interlaced using polyester yarn. As a result, the direct contact between electric conductive yarns was restrained, which would be interposed into pin-tuck structured cable. Washable silicone gel applied around the electrode made of electric conductive fabric improved the adhesion, which prevents electrodes from dropping off from the skin surface during body movement. ECG signals on the human subject were tested using the garment apparatus developed by the above method. And the result was that the clear QRS wave formation in the typical form of ECG could be measured in both conditions of still and moving state as well. The result of this study is expected to contribute for the production of U-health care related medical apparatus by accelerating the practical uses of the garment measuring vital sign at a reasonable price.

고전압 전력기기 개발을 위한 기중 절연파괴특성 분석에 관한 연구 (A Study on the Lightning Impulse Dielectric Characteristics of Air for the Development of Air-Insulated High Voltage Apparatuses)

  • 남석호;강형구
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1005-1010
    • /
    • 2011
  • The accidents caused by dielectric instability have been increasing in power grid. It is important to enhance the dielectric reliability of a high voltage apparatus to reduce the damage from electrical hazards. To develop an electrically reliable high voltage apparatus, the experimental study on the electrical breakdown field strength is indispensable, as well as theoretical approach. In this paper, the lightning impulse breakdown characteristics considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only maximum electric field intensity but also utilization factors of electrode systems. The results are expected to be applicable to designing the air-insulated high voltage apparatuses.

유한요소법을 이용한 초정밀 미동스테이지 설계에 관한 연구(I) (A Study on the Design of Ultra Precision Positioning Apparatus using FEM (I))

  • 김재열;윤성운;김항우;한재호;곽이구
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.190-194
    • /
    • 2001
  • Because, Piezo-electric transducer(PZT) transform electric energy into mechanical energy, it is a adequate material for positioning control and force control, take excellent properties as actuator with high speed and high performance. Recently, researches of ultra precision positioning using this PZT are advanced in. In this paper, we use a actuator of PZT, design a positioning apparatus with ultra precision position apparatus as hinge structure. Because of this purpose, before, we were confirmed in control properties of ultra precision stage by FEM method.

  • PDF