• 제목/요약/키워드: Electric and Magnetic Field

Search Result 768, Processing Time 0.03 seconds

Study on Heat Generation of a Bulk HTS for Application to a 100 kWh SFES Superconductor Bearing

  • Jung, S.Y.;Lee, J.P.;Han, Y.H.;Han, S.C.;Jeong, N.H.;Ko, J.S.;Jeong, S.K.;Sung, T.H.
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.122-126
    • /
    • 2006
  • This paper presents experimental and numerical investigation on heat generation of a bulk HTS for application to a 100 kWh Superconductor Flywheel Energy Storage System(SFES) bearing. An experimental device is manufactured to reproduce varying magnetic field conditions that a bulk HTS may experience during the operation of the 100 kWh SFES. The bulk HTS is directly cooled by a cryocooler while the heat is generated by the eddy currents created by varying magnetic fields induced by a coil. In order to design the cryocooling system for the 100 kWh SFES project, a preliminary experiment to investigate the actual cooling load variation under AC magnetic field has been carried out. In the experiment, two different copper holders were designed and tested. Several temperature sensors were installed on each component of the assembly and the temperatures were measured for several operating conditions of the 100 kWh SFES. The experimental investigation on the thermal response of the bulk HTS and its holder is considered to be a valuable step fur the successful materialization of a large-scale SFES.

  • PDF

A Study on Development of Current Map Model Based on Electromagnetic Field Design (전자계 설계 기반 전류맵 모델 개발에 관한 연구)

  • Park, Gui-Yeol;Hwang, Yo-Han;Choi, Jong-Sil;Lee, Ju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.454-461
    • /
    • 2021
  • To control the torque of the IPMSM, a lookup table is generally used in control system because of its nonlinear characteristics. However, the method of generating the lookup table data has the disadvantage of having difficulty accurately analyzing the changing parameters, generating the current or magnetic flux map is complicated and long test time taken due to motor temperature differences at each test points. In this paper, on the basis of the electromagnetic field design of IPMSM, we devised an electromagnetic field-based magnetic flux map model that can compensate for the pre-generated magnetic flux map through a quick and simple test.

EQUIVALENT CIRCUIT REPRENSENTATION OF MAGNETIC FIELDS BASED ON FINITE ELEMENT MODELLING

  • Y. Kagawa;N. Wakatsuki;Kim, A. ura
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.205-208
    • /
    • 2001
  • A lumped electrical circuit is an approximate representation of the field within a curtain frequency range. The finite element modelling is a synonym of the equivalent circuit. The electric conduction field and electric potential wave field have been modelled by an admittance network and an LC low-pass filter network. Here in the present paper, the equivalent magnetic circuit representation is created for a magnetostatic field by the finite element modelling in two dimension.

  • PDF

Magnetic field effect on the positive column of fluorescent lamp (형광등 Positive column에 대한 자장인가 효과)

  • 지철근;김창종
    • 전기의세계
    • /
    • v.31 no.3
    • /
    • pp.197-203
    • /
    • 1982
  • The effects on the characteristics of 20-W fluorescent lamp were studied when applying magnetic field to its positive column. First, when the direction of the magnetic field is axial, i.e., along the lamp, if the magnitude of the field is stronger than the critical field, lamp voltage is increased, lamp current decreased, luminous flux increased, starting voltage decreased, as increasing the applied magnetic field. At the magnetic flux density is 130 gauss, luminous flux is increased to about 6 percents and starting voltage is increased to about 45 percents. Second, when the direction of the magnetic field is transverse to the lamp axis, as increasing the applied magnetic field, lamp voltage is increased, lamp current decreased, luminous flux increased and starting voltage is nearly constant, but the rates of increase or decrease of this case is different from those of the first. At the magnetic flux density is 300 gauss, luminous flux is increased about 45 percents. In both cases, electric power dissipated by lamps is the same as that of the lamp which magnetic field is not applied to.

  • PDF

Induced Current Calculation in a Human Body Model due to Magnetic field in High Speed Railway (고속철도내 자기장에 의한 인체 모델에서의 유도 전류 계산)

  • Han, In-Su;Lee, Tae-Hyung;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.208-213
    • /
    • 2008
  • In recent society, the quality of human life has improved due to the use of electric appliances and the high powered electrical equipments. However, lots of electric appliances and equipments generate the electromagnetic field hazard. Many studies have been made about the wrong behavior of machines due to electromagnetic fields, the interferences in communication equipments, the possibility of the electromagnetic field hazard in human body, etc. There exist international standards about the RF equipments (ex. mobile phone, antenna, etc.). But, many researchers involved in power frequency electric and magnetic field only propose the prudential avoidance. In this paper, induced currents in a human body model due to magnetic fields in high speed railway are calculated by two dimensional impedance method. Power frequency(60Hz) magnetic fields are calculated and induced currents are simulated by Faraday's law. Induced currents are simulated with induced voltage, human body model impedances due to Ohm's law, magnetic fields derived from Biot-Savart's law and Transmission Line Method in high speed railway.

  • PDF

Survey on Magnetic Field around Substations and Proposals to Broaden Understanding of the Magnetic Field Characteristics (변전소 주변 자계 실태조사 및 자계 특성이 이해증진 방안)

  • Rhee, Seong-Su;Shin, Heon-Shik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.6
    • /
    • pp.526-534
    • /
    • 2009
  • The magnetic field of the extremely low frequency that occurs in the substation facilities was surveyed to present ways to broaden understanding of the magnetic field characteristics. We have investigated the level of the magnetic fields in the substation areas and control rooms of 25 substations in the metropolitan area in accordance with the measurement method of IEC CISPR(IEC/TC106 PT 62110). We propose objective and reliable policy approaches such as the electromagnetic field certification system to more accurately understand the property of magnetic field.

Research about design and manufacture of own nerve system for core formation rehalititation treatment (근조직 재활치료를 위한 자기신경 시스템의 설계 및 제작에 관한 연구)

  • Kim, Whi-Young;Choe, Jin-Yeong;Park, Seong-Jun;Kim, Jin-Yeong;Park, Seong-Jun;Kim, Hui-Je
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2171-2172
    • /
    • 2006
  • Magnetic nerve stimulation treatment is much backward real condition than other field. Specially, successful medical treatment introduction of magnetic field (MF) can was refered long ago in Avicenna's work, and is thought as age of medicine magnetology development recently. These development is achieved through biologist and biophysicist and clinician's joint effort, but, new mountings and relationship air tassel are developed steadily. Magnetic nerve stimulation treatment field designs treatment system by each function during long wave high-amplitude (traditional magneto therapy of greatly great that strong that) short time that CMF, VMF, PMF field etc. are representative but are HPMT technology in this research and manufacture and special quality did comparative analysis.

  • PDF

Optical Current Measuring System for Compensating Interference by Adjacent Electric Wires

  • Cho, Jae-Kyong
    • Journal of Magnetics
    • /
    • v.12 no.4
    • /
    • pp.156-160
    • /
    • 2007
  • In this paper, we analyze the errors associated with magnetic field interference for fiber-optic current sensors working in a three-phase electric system and provide a solution to compensate the interference. For many practical conductor arrangements, the magnetic filed interference may cause errors unacceptable for the accuracy requirements of the sensors. We devised a real time compensation method for the interference by introducing geometric and weight factors. We realized the method using simple electronic circuits and obtained the real time compensated outputs with errors of ${\pm}1%$.

A Study on the Analysis of the Magnetic Fields Generated by the operation of Electric Appliances (전기기구의 운전중에 발생되는 자계성분해석에 관한 연구)

  • Lee, Bok-Hee;Park, Hyung-Ki;Chung, Seung-Soo;Paek, Yong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.575-577
    • /
    • 1993
  • In this study, the reponse characteristic of the time-changing magnetic field measurement system by using the self-integrated magnetic sensor is investigated. The measurement system has the frequency bandwidth of 40[Hz]-50[kHz]. The time-changing magnetic fields generated by the operations of small-size electric machines are investigated. The magnetic field generated by the starting and/or the operation of electric appliances mainly includes the odd harmonics such as the third, the fifth, the seventh, and so on.

  • PDF

Measurement and Analysis of Electromagnetic field for DC electric railway train (직류철도차량에 대한 자계측정 및 분석)

  • Jang, Dong-Uk;Kim, Min-Cheol;Lee, Chang-Mu;Han, Moon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1637-1639
    • /
    • 2005
  • The measurement of magnetic field is performed about DC and AC magnetic field in test track of depot. The test point is cap, on the converter/inverter box, on the traction motor, on the APSE and on the line filter, the height of measurement is bottom and 50 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through RS-232C and notebook PC. The DC magnetic field is measured by using the Hall Probe, test result is saved and analysis by PXI system. On the line filter, the maximum value is 1.4 mT in case of DC magnetic field and 0.044 mT in case of AC magnetic field at 50 Hz.

  • PDF