• Title/Summary/Keyword: Electric Wires

Search Result 181, Processing Time 0.028 seconds

Catenary Measurement System for Real-Time Automated Diahnosis (실시간 자동화 진단을 위한 전차선 검측시스템)

  • Kim, Jeong-Yeon;Park, Jong-Gook;Lee, Byeong-Gon;Hong, Hyun-Pyo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1020-1026
    • /
    • 2011
  • In this paper, we propose a method that measures the height and stagger of an catenary using the laser profile images. One line laser and area scanner CCD cameras are used. To quickly and accurately extract, from a photographed image, the area of the overhead line on which the line laser is shone, we consider the established fact that the catenary is the lowest among the electric wires. Here we are solving the the distance to the catenary if we know the distance the camera is from the ground and the angle of the catenary in the field of view. The angle will be related to the number of pixels in the image. This pixels per degree is a constant for the camera. Also, because of the different pixel resolution of the camera according to the overhead line position, we compensate the measurement result through camera calibration.

  • PDF

Analysis of Return Current by Common Earth on Electrical Line of the Gyeongbu Line (경부선 전철화 구간에서의 공동접지에 의한 귀선전류 분석)

  • Kim, Yong-Kyu;Baek, Jong-Hyen
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4968-4974
    • /
    • 2010
  • Electrical Railroads provide electric power, which can operate vehicles, via feeder wires. And the supplied current returns to the transformer substation through lines and ground net. In domestic cases, the configuration of ground net affecting such a return current mostly uses an exclusive earth method. However, along with the introduction to Gyeongbu HSL(High Speed Line), the concept of Common Earth was applied to Electrical Railroads. In this paper, based on the return currents analyzed to be measured in the electrified sections for the operation of High Speed Rails in existing lines, we analyze the relations between earth methods and return currents in electrified sections. For analysis, we utilize the measured values of return currents measured in track circuits in Gyeongbu HSL, and predictive values of those compared to the earth methods between Gyeongbu HSL and the existing electrified sections.

Fiber Optic Displacement Sensor System for Structural Health Monitoring (구조 건전성 모니터링을 위한 광섬유 변위 센서 시스템 개발)

  • Lee, Kun-Ho;Ahn, Byung-Jun;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.374-381
    • /
    • 2011
  • It has been doing to research on novel techniques for structural health monitoring by applying various sensor techniques to measure the deflection in mechanical and civil structures. Several electric-based displacement sensors have many difficulties for using them because of EMI (Electro-Magnetic Interference) noise of many lead-wires when they are installed to many points in the structures. In this paper, it is proposed an affordable intensity-based fiber optic sensor to measure small displacement solving the problems of conventional sensors. In detail, the sensor head was designed on the basis of the principle of bending loss and a basic experiment was performed to obtain the sensitivity, the linearity and the stroke of the sensor. Moreover, a prototype was designed and manufactured to be easily installed to a structure and a real-time control software was also successfully developed to drive the fiber optic sensor system.

The Feasibility Study of a Light Rail Transit Development (경량전철 개발에 따른 경제적 파급효과 분석 연구)

  • Nam, Doo-Hee;Lim, Kwan-Su;Lee, Jin-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.1
    • /
    • pp.119-124
    • /
    • 2010
  • Light rail is an electric railway system, characterized by its ability to operate single or multiple car consists (trains) along exclusive rights-of-way at ground level, on aerial structures, in subways or in streets, able to board and discharge passengers at station platforms or at street, track, or car-floor level and normally powered by overhead electrical wires. Depending upon the specific system, the light rail lends some major advantages to urban settings. The evaluation of light rail technology as a potential component of regional transit systems has been the subject of extensive studies throughout the country in the past decade. For the study, feasibility was defined as "the ability of an LRT system to achieve certain level of transportation market in comparison with other transportation alternatives." This paper describes the feasibility study to evaluate a proposed light rail development project. The minimum are those LRT systems that would met to make a project feasible for further evaluation.

Development of Parallel Plate Avalanche Counter for heavy ion collision in radioactive ion beam

  • Wei, Xianglun;Guan, Fenhai;Yang, Herun;Wang, Yijie;Zhang, Junwei;Ma, Peng;Diao, Xinyue;Lu, Chengui;Li, Meng;Guan, Yuanfan;Duan, Limin;Hu, Rongjiang;Zhang, Xiuling;Xiao, Zhigang
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.575-580
    • /
    • 2020
  • We have developed a position-sensitive Parallel Plate Avalanche Counter (PPAC) to detect the fission fragments and reconstruct the fission reaction plane in the experiment of studying nuclear equation of state (nEOS) by means of heavy ion collision (HIC). This experiment put forward high requirements for the performances of PPAC, such as the time resolution, efficiency and position resolution. According to these requirements we designed the PPAC with an active area of 240 mm × 280 mm working at low gas pressure. The results show that time resolution could be less than 300 ps. Position resolution is consistent with the theoretical calculation about 1.35 mm. Detection efficiency could be approaching 100% gradually with the voltage increasing in different gas pressures. The performances of PPAC have also been verified in beam experiment. Each set of anode wires can be accurately separated in the position spectrum. In the beam experiment, we also got the back-to-back correlation of fission fragments which is one of the direct signals characterizing binary decay.

Analysis on the dielectric characteristics of a composite insulation system composed of LN2 and GN2

  • Kim, Junil;Lee, Onyou;Mo, Young Kyu;Bang, Seungmin;Kang, Jong O;Lee, Hongseok;Nam, Seokho;Kang, Hyoungku
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.33-36
    • /
    • 2015
  • A liquid nitrogen ($LN_2$) is usually used to be a coolant and insulant for a HTS coil system. HTS wires for a superconducting apparatus may be surrounded by gaseous nitrogen ($GN_2$) due to film boiling generated by a quench or voids occurred by electrical breakdown. The increased maximum electric field intensity at $GN_2$ may result in the degradation of dielectric strength of a HTS coil system. In this paper, a study on the dielectric characteristics of a composite insulation system composed of $LN_2$ and $GN_2$ is performed. A sphere-to-plane electrode system made with stainless steel is used to perform the experiments under AC and lightning impulse voltage condition. A sphere electrode is surrounded by $GN_2$ and a plane electrode is immersed into $LN_2$ to conduct dielectric experiments with a composite insulation system. The dielectric experiments are performed according to the level of $LN_2$ from the plane electrode to a sphere electrode. It is found that the dielectric characteristics of a composite insulation system are dependent on the level of $LN_2$ and the field utilization factor of an electrode system.

Current Sharing of Parallel Connected Bi-2223 High-$T_{c}$ Superconducting paths

  • Bae, Duck-Kweon;Hyoungku Kang;Ahn, Min-Cheol;Kim, Yeong-Sik;Yoon, Kyung-Yong;Yoon, Yong-Soo;Bae, Jun-Han;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.20-24
    • /
    • 2004
  • Bi-2223 wire, the first-generation high temperature superconducting (HTS) wire, was successfully commercialized and various electrical machinery and equipment are actively being developed in many countries. Because its critical current is too small to realize the lossless conducting part of electric power system with a HTS wire, multi-HTS paths are used to enlarge the critical current of HTS system. Though the resistance generated in HTS wire by transport current is very small, the difference of it in multi-path is the additional reason which causes the non-uniform current sharing in multi-HTS path except the well known reason, the difference of inductance between each path. In this paper, experimental research on current sharing of multi-strand and multi-stacked HTS wire was implemented. The whole critical current of multi-HTS paths is not equal to sum of critical current of each path because of non-uniform current sharing occurred in this paths. It was verified experimentally that Bi-2223 wires have different resistance generated by same transport current even if they was manufactured in same progress of work. Current sharing phenomenon was affected by difference of resistance and self and mutual inductance.

Performance and analysis of wireless power charging system from room temperature to HTS magnet via strong resonance coupling method

  • Chung, Y.D.;Lee, C.Y.;Lee, S.Y.;Lee, T.W.;Kim, J.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.41-45
    • /
    • 2016
  • The technology of supplying the electric power by wireless power transfer (WPT) is expected for the next generation power feeding system since it can supply the power to portable devices without any connectors through large air gap. As such a technology based on strongly coupled electromagnetic resonators is possible to deliver the large power and recharge them seamlessly; it has been considered as a noble option to wireless power charging system in the various power applications. Recently, various HTS wires have now been manufactured for demonstrations of transmission cables, motors, MAGLEV, and other electrical power components. However, since the HTS magnets have a lower index n value intrinsically, they are required to be charged from external power system through leads or internal power system. The portable area is limited as well as the cryogen system is bulkier. Thus, we proposed a novel design of wireless power charging system for superconducting HTS magnet (WPC4SM) based on resonance coupling method. As the novel system makes possible a wireless power charging using copper resonance coupled coils, it enables to portable charging conveniently in the superconducting applications. This paper presented the conceptual design and operating characteristics of WPC4SM using different shapes' copper resonance coil. The proposed system consists of four components; RF generator of 370 kHz, copper resonance coupling coils, impedance matching (IM) subsystem and HTS magnet including rectifier system.

Development of Moving Objects Monitoring and Transforming Personal Robot System Based on Remote Controls (원격제어기반 이동체 감지 및 변형 퍼스널 로봇시스템 설계 및 구현)

  • Lee, Dong-Myung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.159-165
    • /
    • 2010
  • The moving object monitoring and transforming personal robot system based on remote controls is designed and implemented, and the performance of the system is analyzed in this paper. The major considering factors in the system design are such as 1) the control scheme design (button based and the remote control schemes); 2) the operation modes design (wheel driving mode/pedestrian mode/auto driving mode/observation mode); 3) the remote control function design; 4) the design of the monitoring function of the changes in neighbor environments; 5) the design of the detection of obstruction. From the experiments, it is assured that the developed personal robot can walk to the grounds that covered with doorsill or electric wires in indoors by control the leg articulations, and can escape from the obstruction using three infrared sensors in the 30cm*30cm obstruction styled space under the auto driving mode.

Review of SQUID Sensors for Measuring Magnetocardiography (심자도 측정을 위한 SQUID 센서 기술의 개발 현황)

  • Lee, Y.H.;Kim, J.M.;Yu, K.K.;Kim, K.;Kwon, H.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.