• Title/Summary/Keyword: Electric Service

Search Result 708, Processing Time 0.033 seconds

An Evaluation of Weather Model for Increasing Ampacity in KEPCO's Overhead Transmission Lines (한국전력 가공송전선의 허용전류를 증가시키기 위한 기상모델의 평가)

  • 김성덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.125-134
    • /
    • 2004
  • The new deregulated economic environment in the power utility market is forcing fundamental changes in the investment and operational decisions regarding transmission lines. Hence, it has come to be an important issue to evaluate their current utility in order to increase conductor ampacity based on conservative assumptions of worst case weather conditions. Static thermal rating has born still applied in most power companies worldwide, however some of them have been done various trials such as monitoring dynamic line ratings to increase line ratings in real time. This study is an attempt to access the static line ratings in Korea Electric Power Corporation(KEPCO) transmission lines, which were specified by weather model. Several environmental performances for determining static line ratings are examined by using the past weather data of Korean Meteorological Administration. As a result, it is shown that seasonal or regional line ratings could be adopt to the KEPCO's transmission lines, and their line ratings could be more increased without refurbishing current conductors in service to new high-temperature ones.

Design and Implementation of an Interface Module for the ETC System using Mobile Phone (휴대폰 기반 ETC시스템을 위한 인터페이스 모듈 설계 및 구현)

  • Shin Song-Ah;Yim Joe-Hong
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.881-889
    • /
    • 2004
  • Using the ETC Service, it is now possible to charge a vehicle for driving pass a specific toll booth electronically, without the vehicle even having to slow down. The smart card and card reader used to collect tolls electronically have a serious problem which it dose not have a standard for the ETC system. In this paper, we suggest the ETC system using mobile phone to collect tolls efficiently instead of existing system which is consist of a Interface Module to connect between a mobile phone and OEE, a mobile phone to send the information of tollgate fees and OEE to communication with RSE of roadway in the vehicle. This primary focus of this system is the IM functions and protocol to assist of the existing mobile phone and OBE.

Evaluation of Grooving Corrosion and Electrochemical Properties of H2S Containing Oil/Gas Transportation Pipes Manufactured by Electric Resistance Welding

  • Rahman, Maksudur;Murugan, Siva Prasad;Ji, Changwook;Cho, Yong Jin;Cheon, Joo-Yong;Park, Yeong-Do
    • Corrosion Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.109-115
    • /
    • 2018
  • Electrical Resistance Welding (ERW) on a longitudinal seam-welded pipe has been extensively used in oil and gas pipelines. It is well known that the weld zone commonly suffers from grooving corrosion in ERW pipes. In this paper, the grooving corrosion performances of API X65 grade non-sour service (steel-A) and API X70 grade sour gas resistant (steel-B) steel electrical resistance welding pipelines were evaluated. The microstructure of the bondline is composed of coarse polygonal ferrite grains and several elongated pearlites. The elongated pattern is mainly concentrated in the center of the welded area. The grooving corrosion test and electrochemical polarization test were conducted to study the corrosion behavior of the given materials. A V-shaped corrosion groove was found at the center of the fusion zone in both the steel-A and steel-B ERW pipes, as the corrosion rate of the bondlines is higher than that of the base metal. Furthermore, the higher volume fraction of pearlite at the bondline was responsible for the higher corrosion rate at the bondline of both types of steel.

Improvement Method of Regional Insulation Standard through the Regional Heating Energy Demand Analysis (권역별 난방에너지 요구량 분석을 통한 단열기준 개선방안)

  • Kim, Jeong-Gook;Ahn, Byung-Lip;Jang, Cheol-Yong;Jeong, Hak-Geun;Haan, Chan-Hoon
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.43-48
    • /
    • 2013
  • The effect of climate change has influenced humanity and ecosystem with tremendous changes in temperature. For the past 150 years, the national annual average temperature is 0.6 degree increased and the heating degree day reduced from April to November. However, December to January, the climate change was generated and the heating degree day increased. The blackout occured in 2011 and 2012 by increasing electricity consumption of heating and cooling equipment to the effects of climate change. That is because heating load accounted for 20% of building electric use. In this study, strengthening measures to reduce heating energy consumption is presented due to climate change in winter since 1980 to prevent blackout and reliable power supply for the building energy-saving design standards by Meteorological data provided by the National Weather Service were calculated using the heating degree days in order to present eighteen cities from 1980 to 2012. Insulation standards are presented to prevent black-out by the heating degree days. the heating energy demand was reduced almost 6% including 10% in Central, 5% in South and Jeju area based on strengthening of the insulation. It is applied to the entire country an annual economic effect of 250 billion won, and black-out can be prevented.

Analysis of Harmonic Effects on Substation Power System and its Countermeasure (지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.

The Evaluation of Energy Saving using Ultrathin Heat Insulation in Railway Electrification Substation (철도전기실의 초박형 액체단열재 적용을 통한 에너지 절감효과)

  • Kim, Hyungchul;Jang, Junghoon;Shin, Sungkwon;Park, Yongsub;Kim, Sangam;Kim, Hyeong Rae;Hyun, Byungsoo;Kim, Jinho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.171-175
    • /
    • 2015
  • In this paper, because of global environmental problems such as energy shortage and abnormal climate, green energy development and energy saving technology development is being magnified. Heat insulation, the most basic and traditional energy saving method, is highly expected. Especially, simple and advanced heat insulation technique based on Nano material is promising future technology. The railway system also requires heat insulation. Especially, traditional heat insulator such as glass wool has been adopted frequently to rolling stock. The heat insulator is also adopted in general railway service buildings. Take account of cost-effective heat blocking performance, the heat insulator shall be adopted in diverse fields such as electric power, railroad, signal and communication. The only and direct solution for this problem is installing heat insulator with outstanding endurance, corrosion resistance and heat resistance to block outer heat Upgrading heat specification of equipment can be a solution, but since price and maintenance cost rise severely, this plan might be incongruous. In this research, energy saving effect of ultrathin heat insulator film was demonstrated by installing the film on roof of electrical room.

Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes (구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수)

  • Eem, Seung-Hyun;Choi, In-Kil;Jeon, Bub-Gyu;Kwag, Shinyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

Degradation Damage Evaluation for Turbine Structural Components by Electrochemical Reactivation Polarization Test (전기화학적 재활성화 분극시험에 의한 터빈부재의 열화손상 평가)

  • Kwon, Il-Hyun;Baek, Seung-Se;Lyu, Dae-Young;Yu, Hyo-Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1241-1249
    • /
    • 2002
  • The extent of materials deterioration can be evaluated accurately by mechanical test such as impact test or creep test. But it is almost impossible to extract a large test specimen from in-service components. Thus material degradation evaluation by non-destructive method is earnestly required. In this paper, the material degradation for virgin and several aged materials of a Cr-Mo-V steel, which is an candidated as structural material of the turbine casing components for electric power plant, is nondestructively evaluated by reactivation polarization testing method. And, the results obtained from the test are compared with those in small punch(SP) tests recommended as a semi-nondestructive testing method using miniaturized specimen. In contrast to the aged materials up to 1,000hrs which exhibit the degradation behaviors with increased ${\Delta}[DBTT]_{SP}$, the improvement of mechanical property can be observed on the 2,000hrs and 3,000hrs aged materials. This is because of the softening of material due to the carbide precipitation, the increase of ferritic structures and the recovery of dislocation microstructure by long-time heat treatment. The reactivation rates($I_R/I_{Crit},\;Q_R/Q_{Crit}$) calculated by reactivation current densityt ($I_R$) and charge($Q_R$) in the polarization curves exhibit a good correlation with ${\Delta}[DBTT]_{SP}$ behaviors.

Analysis of impact of CATV leakage on CDMA Mobile Communication Systems (CDMA 이동통신시스템에 대한 케이블 방송 전송설비 누설전자파 영향 분석)

  • Park, Seong-Gyoon;Han, Chan-Kyu
    • Journal of IKEEE
    • /
    • v.15 no.3
    • /
    • pp.218-226
    • /
    • 2011
  • In this paper, the leaky electric field intensity of outdoor CATV facilities on CDMA mobile service band defined in technical regulation related with CATV is investigated if appropriate or not. From experimental and theoretical analysis results, Maximum allowable power level of CATV leakage should be -110dBm/1.23MHz. Also, the CATV leakage intensity thresholds, which may not nearly give an impact on the uplink performance of CDMA mobile base station for outdoor background noise of -100~-80dBm/1.23MHz to be measured in outdoor environment, couldn't conform to the current CATV technical regulation. Therefore, the leakage intensity in the current CATV technical regulation is rated as a too much low level in view of an overly worst case.

SD(Short Data) Performance Measurement in D-TRS Wireless Network Environment (D-TRS 무선망환경에서의 SD(Short Data) 성능측정)

  • Song, Byung-Kwen;Kim, Geon-Ung
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.80-86
    • /
    • 2009
  • TETRA is the standard of Digital Trunked Radio System developed by the ETSI(European Telecommunications Standards Institute). It is adopted as Electric Power IT Wireless Backbone Network in Korea. To use TETRA wireless network, TETRA modem is very necessary. In this paper, the performance measurements of modem and its results are analyzed according to traffics in TETRA network. In this paper, SDS type-4 transmission method is used in the transmission standards suggested by PEI(Peripheral Equipment Interface) of ETSI. Performance measurements are done by varying the data size and transmission interval. The data size is increased by 10 bytes from 10-byte to 140-byte, and it is measured 1,000 times for each transmission interval of 0.5, 1.0, and 1.5 seconds. MU-1000MD of Unimo is used for TETRA modem, and SwMI(Switching and Management Infrastructure) of Teltronic is used for switching system in this paper.

  • PDF