• Title/Summary/Keyword: Electric Range

Search Result 1,647, Processing Time 0.038 seconds

Growth and optical properties for MgGa2Se4 single crystal thin film by hot wall epitaxy (Hot wall epitaxy법에 의한 MgGa2Se4 단결정 박막 성장과 광학적 특성)

  • Moon, Jong-Dae;Hong, Kwang-Joon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.3
    • /
    • pp.99-104
    • /
    • 2011
  • A stoichiometric mixture of evaporating materials for $MgGa_2Se_4$ single crystal thin films was prepared from horizontal electric furnace. The crystal structure of these compounds has a rhombohedral structure with lattice constants $a_0=3.953\;{\AA}$, $c_0=38.890\;{\AA}$. To obtain the single crystal thin films, $MgGa_2Se_4$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the Hot Wall Epitaxy (HWE) system. The source and substrate temperatures were $610^{\circ}C$ and $400^{\circ}C$, respectively. The crystalline structure of the single crystal thin films was investigated by the double crystal X-ray rocking curve and X-ray diffraction ${\omega}-2{\theta}$ scans. The carrier density and mobility of $MgGa_2Se_4$ single crystal thin films measured from Hall effect by van der Pauw method were $6.21{\times}10^{18}\;cm^{-3}$ and 248 $cm^2/v{\cdot}s$ at 293 K, respectively. The optical absorption of $MgGa_2Se_4$ single crystal thin films was investigated in the temperature range from 10 K to 293 K. The temperature dependence of the optical energy gap of the $MgGa_2Se_4$ obtained from the absorption spectra was well described by the Varshni's equation, $E_g(T)=E_g(0)-({\alpha}T^2/T+{\beta})$. The constants of Varshni's equation had the values of $E_g(0)=2.34\;eV$, ${\alpha}=8.81{\times}10^{-4}\;eV/K$ and ${\beta}=251\;K$, respectively.

Safety and Efficacy of Peripherally Inserted Central Catheters in Terminally Ill Cancer Patients: Single Institute Experience

  • Park, Kwonoh;Lim, Hyoung Gun;Hong, Ji Yeon;Song, Hunho
    • Journal of Hospice and Palliative Care
    • /
    • v.17 no.3
    • /
    • pp.179-184
    • /
    • 2014
  • Purpose: We investigated the safety and efficacy of peripherally inserted central catheters (PICCs) in terminally ill cancer patients. Methods: A retrospective review was conducted on patients who underwent PICC at the hospice-palliative division of KEPCO (Korea Electric Power Corporation) Medical Center between January 2013 and December 2013. All PICCs were inserted by an interventional radiologist. Results: A total of 30 terminally ill cancer patients received the PICC procedure during the study period. Including one patient who had had two PICC insertions during the period, we analyzed a total of 31 episodes of catheterization and 571 PICC days. The median catheter life span was 14.0 days (range, 1~90 days). In 25 cases, catheters were maintained until the intended time (discharge, transfer, or death), while they were removed prematurely in six other cases (19%; 10.5/1000 PICC days). Thus, the catheter maintenance success rate was 81%. Of those six premature PICC removal cases, self-removal due to delirium occurred in four cases (13%; 7.0/1000 PICC days), and catheter-related blood stream infection and thrombosis were reported in one case, each (3%; 1.8/1000 PICC days). Complication cases totaled eight (26%; 14.1/1000 PICC days). The time to complication development ranged from two to 14 days and the median was seven days. There was no PICC complication-related death. Conclusion: Considering characteristics of terminally ill cancer patients, such as a poor general condition, vulnerability to trivial damage, and a limited period of survival, PICC could be a safe intravenous procedure.

The Effect of Heating Rate by Ohmic Heating on Rheological Property of Corn Starch Suspension (Ohmic Heating에 의한 가열속도 변화가 옥수수전분의 물성특성에 미치는 영향)

  • Lee, Seok-Hun;Jang, Jae-Kweon;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.438-442
    • /
    • 2005
  • Granule swelling is essential phenomenon of starch gelatinization in excess water, and characteristic of heated starch dispersion depends largely on size and distribution of swelled starch granule. Although swelling characteristic of starch granules depends on type of starch, heating rate, and moisture content, influence of heating rate on swelling phenomenon of starch granule has not been fully discussed, because constant heating rate of starch dispersion cannot be obtained by conventional heating method. Ohmic heating, electric-resistant heat generation method, applies alternative current to food materials, through which heating rate can be easily controlled precisely and conveniently at wide range of constant heating rates. Starch dispersion heated at low heating rates below $7.5^{\circ}C/min$ showed Newtonian fluid behavior, whereas showed pseudoplastic behavior at heating rates above $16.4^{\circ}C/min$. Apparent viscosity of starch dispersion increased linearly with increasing heating rate, and yield stress was dramatically increased at heating rates above $16.4^{\circ}C/min$. Average diameter of corn starch granules during ohmic heating was dramatically increased from $30.97\;to\;37.88\;{\mu}m$ by increasing heating rate from $0.6\;to\;16.4^{\circ}C/min$ (raw corn starch: $13.7\;{\mu}m$). Hardness of starch gel prepared with 15% corn starch dispersion after heating to $90^{\circ}C$ at different heating rates decreased gradually with increasing heating rate, then showed nearly constant value from $9.4\;to\;23.2^{\circ}C/min$. Hardness increased with increase of heating rate higher than $23.2^{\circ}C/min$.

The Profile of Milling Plants in Korea (우리나라 양곡가공공장의 현황분석)

  • 정창주;금동혁;강화석
    • Journal of Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.47-63
    • /
    • 1978
  • This study was conducted to obtain a basic information necessary to assess present rice milling technology in Korea The profiles for milling plants was analyzed by survey work.For the private custom-work mills, which process about 80 percent of domestic rice consumption ,their actual milling test for the identical samples as used for filed mills was conducted. Two rice varieties Japonica and Tongil-type were associated with the experiments. The results are summarized as follows: 1. Analyses for private custom-work mills showed their general aspects as; about 91 percent of the mills belonged to an individual owner ship ; more than 93 percent of the mills was established earlier than 1950 ; about 80 percent of the mills was powered with electric motor; mills having less than two employees were about 75 percent; about 45 percent of the mills provided for warehouse in storing customers cereal grains. 2. The polishers installed in 1,255mills within the surveyed area (7 counties) have been supplied by 44 different domestic manufacturers ;in but about 60 percent of which was supplied by 6major manufacturers. The polishers could be classified into two categories in terms of principles of their polishing actions ;jet-pearler and friction types. About 51 percent of the mills was equipped with the former which has been recognized as giving greater milling recovery than the friction types. 3. Reason for owners of private mills to supplement new machines was due mainly to pgrading their mills to meet the requirements that established by the Government. However, about 60 percent of the mill owners intended to replace with new pearler by their own needs to meet with new high yielding varieties. 4. Processing systems of each previate rice mills surveyed could be classified into three categories, depending upon whether the systems posessed such components as precleaner and paddy separator or not. Only 36.7 percent of mills was installed with both precleanr ad paddy seperrator, 5.0 percent of mills did have neither percleaner nor paddy seperator, and rest of them equipped only one of the two. Hence,it is needed for about 63% of rice miils to be supplemented with these basic facilities to meet with the requirements for the standaized system. 5. Actual milling capacity measured at each field rice mills was shown a wide variation, having range from about 190 to 1,210 kg/hr. The percentages of mills classified according to daily milling capacity based on this hourly capacity were 24.3% for the capacity less than 3 M/T a day; 20.0% for 3-4 M/T; 15.6% for 4-5 M/T; 6.7% for 5-6 M/T; 22.3% for 6-7 M/T; and 11.0% for more than 7 M/T a day. 6. Actual amount of rice processed was about 310 M/T a year in average. About 42% of total milled rice was processed during October to Decembear, which formed a peak demand period for rice mills. The amount of rice milled during January to May was relatively small, but it had still a large amount compared to that during June to September. 7. Utilization rate of milling facility, i. e., percentage of the actual amount of milled rice to the capacity of rice mills, was about 18% on the year round average, about 41% in the peak demand season, and about 10% during June to September. Average number of operating days for mills surveyed was about 250 days a year, and about 21 days a month. 8. Moisture contents of paddy at the time of field mill tests were ranged 14.5% to 19.5% for both Japonica and Tong-i] varieties, majority of paddy grains having moisture level much higher than 1530. To aviod potential reduction of milling recovery while milling and deterioration of milled rice while storage due to these high grain mJisture contents, it may be very important for farmers holding rice to dry by an artificial drying method. 9. Milling recovery of JapJnica varieties in rice mills was 75.0% in average and it was widely ranged from 69.0% to 78.0 % according to mills. Potential increase in milJing recovery of Japonica variety with improvement of mill facilities was estimated to about 1.9%. On the other hand, milling recovery of Tong-il varieties in the field mill tests was 69.8% in average and it ranged from 62% to 77 %, which is much wider than that of Japonica varieties. It is noticed that the average milling recovery of Tong-il variety of 69.8% was much less than that of the Japonica-type. It was estimated th3.t up to about 5.0% of milling recovery for Tong-il variety could be improved by improving the present lo'.ver graded milling technology. 10. Head rice recoveries, as a factor of representing the quality of commercial goods, of Japonica and Tong-il varieties were 65.9% and 53.8% in average, and they were widely ranged from 52% to 73% and from 44% to 65% , respectively. It was assessed that head rice recovery of Japonica varieties can be improved up 3.3% and that of Tong-il varieties by 7.0% by improving mill components and systems.

  • PDF

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area - (큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 -)

  • Yoon Yong Cheol;Suh Won Myung;Yu Chan
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.217-225
    • /
    • 2004
  • This study was performed to provide the basic knowledge about the mushroom cultivation facilities. Classified current status of cultivation facilities in Gyeongnam province was investigated by questionnaire. The structure of Pleurotus eryngii cultivation facilities can be classified into the simple and permanent frame type. The simple frame structures were mostly single-span type, on the other hand, the permanent frame structures were more multi-span than simple structures. And the scale of cultivation facilities was very different regardless of structural type. But as a whole, the length, width and ridge height were prevailing approximately 20.0 m, $6.6\~7.0m$ and $4.6\~5.0m$ range, respectively. The floor area was about $132\~160\;m^2$, and floor was built with concrete to protect mushrooms from various harmful infection. The roof slope of the simple and permanent type showed about $41.5^{\circ}\;and\;18.6\~28.6^{\circ}$, respectively. The width and layer number of growing bed for mushroom cultivation were around $1.2\~1.6m$, 4 layers in common, respectively. Most of year round cultivation facilities were equipped with cooler, heater, humidifier, and ventilating fan. Hot water boiler was the most commonly used heating system, the next was electric heater and then steam boiler. The industrial air conditioner has been widely used for cooling. And humidity was controlled mostly by ultra-wave or centrifuging humidifier. But some farmers has been using nozzle system for auxiliary purpose. More then $90\%$ of the mushroom house had the independent environment control system. The inside temperature was usually controlled by sensor, but humidity and $CO_2$ concentration was controlled by timer for each growing stage. The capacity of medium bottle was generally 850 cc and 1100cc, some farms used 800 cc, 950 co and 1,250 cc. Most of mushroom producted has been usually shipped to both circulating company and joint market.

Nonthermal Plasma-assisted Diesel Reforming and Injection of the Reformed Gas into a Diesel Engine for Clean Combustion (디젤의 청정연소를 위한 저온 플라즈마 연료개질 및 개질가스의 디젤엔진 첨가에 관한 연구)

  • Kim, Seong-Soo;Chung, Soo-Hyun;Kim, Jin-Gul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.394-401
    • /
    • 2005
  • A nonthermal plasma-assisted fuel reformer was developed and the effects of operating variables on the performance of this reformer were studied. The $H_2$-rich reformed gas from the reformer was injected into a diesel engine under an idle condition and the effects of the amount of injected gas on the NO and soot reduction were investigated. It was found that with increasing electric power consumption, the degree of facility of ignition of the reforming reaction in the reformer could be enhanced. The performance of the reformer including $H_2$ concentration, $H_2$ recovery, and energy conversion was affected only by the O/C mole ratio. This was because the equilibrium reaction temperature was governed by the O/C mole ratio. With increasing O/C mole ratio, the $H_2$ recovery and energy conversion passed through the maximum values of 33.4% and 66%, respectively, at an O/C mole ratio between 1.2 and 1.5. The reason why the $H_2$ recovery and energy conversion increased with increasing O/C mole ratio when the O/C mole ratio was lower than $1.2{\sim}1.5$ appeared to be that the complete oxidation reaction occurred more enough with increasing O/C mole ratio in this low O/C mole ratio range and accordingly the reaction temperature increased. Whereas the reason why the $H_2$ recovery and energy conversion decreased with increasing O/C mole ratio when the O/C mole ratio was higher than $1.2{\sim}1.5$ appeared to be that the complete oxidation reaction was further advanced and the $H_2$ recovery and energy conversion decreased. As the weight ratio of reformed diesel to total diesel which entered the diesel engine was increased to $18.2{\sim}23.5%$, NO and soot reduction efficiencies increased and reached as values high as 68.5% and 23.5%, respectively.

Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse (온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선)

  • Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.

Physicochemical Changes of Swine Manure by the Treatment of Acid and Alkali for Inactivation of Pathogenic Microorganisms (병원성미생물의 불활성화를 위한 산·알칼리처리가 양돈분뇨의 이화학적 성상에 미치는 영향)

  • Kim, Cho-Long;Kim, Soo-Ryang;Kim, Ha-Je;Jeon, Sang-Joon;Han, Ho;Kim, Dong-Kyun;Lee, Myung-Gyu
    • Journal of Animal Environmental Science
    • /
    • v.18 no.3
    • /
    • pp.229-234
    • /
    • 2012
  • Disinfecting contaminated swine manure with FMD (Foot-and-Mouth Disease) and pathogenic viruses is very important for maintaining sanitized environment. However, very few research reported on this subject, especially post-disinfection to utilize the wastes as a renewable resource. This research is carried out to obtain basic information for chemical treatment in FMD SOP (Standard Operating Procedure, Korea) of contaminated swine manure. Using lime, sodium hydroxide, citric acid and hydrochloric acid, described in FMD SOP, the effects of chemical treatments on livestock manure were compared in this paper. Four combinations of alkali-acid treatments and four kinds of acid-alkali combinations were tested to find out the effective method. Total coliform bacteria in contaminated swine manure, $1.6{\times}10^4$ CFU/100 ml, decreased to the range of 1/1000~1/100 in all treatments. Some specific disinfectants increases BOD (Biochemical Oxygen Demand) and EC(Electric Conductivity), especially, alkaline treatments increases ammonia level than acid treatments. These findings suggest that the treatment methods should be considered as an important environmental factor in post-disinfection of contaminated animal manure with pathogenic microorganisms.

Distribution and Behavior of $^{137}Cs$ According to topography and nature of the soil around Yeong-Gwang NPPs, (영광원자력발전소 주변의 지형 및 지질에 따른 $^{137}Cs$ 분포 및 거동에 관한 연구)

  • Han Sang-Jun;Lee Goung-Jin;Kim Hee-Geun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.4
    • /
    • pp.271-278
    • /
    • 2004
  • This paper shows our experiment is performed to understand the exposure tendency of $^{137}Cs$ according to the height of area and also, to supplement it by considering chemical characters of $^{137}Cs$ exposed to the soil. The samples we use for this experiment are from the general flat area of Yeonggwang county where it has NPPs, the high places of Keumjung & Bulgap mountains, and Naejan mountain where it is quite far from the NPPs. The data from this experiment show that the exposure of $^{137}Cs$ is not harmful since its range is around 252 Bq/kg-dry in most of sampled soils such as from the general flat area, the high place of Keumjung mountain where is 2 km away from the NPPs, the other high place of Bulgap mountain where is about 20 km away from the NPPs, and Naejan mountain where it is far from the NPPs. Not like the general flat area, however, the data show that the higher the area is the more $^{137}Cs$ is exposed. That is, at the top of mountains, the more $^{137}Cs$ is exposed compared to at the bottom area. It is almost $2{\~}6$ times more than the general flat area of Yeonggwang county where it has NPPs. The data also show that the spread of $^{137}Cs$ is deeply related to the geographical(the height of area, rainfall, etc..) factors and chemical factors of soils. As the geographical factors, there are far more chances to be exposed of $^{137}Cs$ at the high area of mountains through the air compared to at lower area and therefore, we can get more high-leveled readings of $^{137}Cs$ at the high area while it is low-leveled ones at the general flat area even if both of them have the same soil conditions. Regarding the chemical factors of soil, it is clarified that the CEC is the key factor. The CEC means the capability of sticking $^{137}Cs$ accumulated into the soil. Hence, the more CEC it has the more high-leveled readings of $^{137}Cs$ we get under the same geographical condition.

  • PDF