• Title/Summary/Keyword: Electric Multiple Unit

Search Result 143, Processing Time 0.025 seconds

Vibration Reduction for the High-Speed EMU under Development (동력분산형 고속전철의 진동저감기술 연구)

  • Shin, Bum-Sik;Chun, Kwang-Wook;Choi, Yeon-Son
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1154-1159
    • /
    • 2008
  • Type of the high-speed train under development has been decided to be EMU(electric multiple Units) following the trend of the times, which is weak for vibration and noise due to the distributed traction unit of motors and gears than that of the articulated high-speed train. Also, passengers may feel uncomfortable at high-speed running due to the various vibration of vehicle itself and bogie, especially due to hunting, snake motion of the high-speed train. In this paper, explained was the program to develop the high-speed EMU at every step of basic and detail design and running test, predict and try to reduce the vibration.

  • PDF

A Study on Lateral Vibration Control Method of High-speed Train (고속열차의 횡진동 제어 특성 연구)

  • Kim, Sang-Soo;Kim, Ki-Hwan;Park, Choon-Soo;Mok, Jin-Yong;Choi, Sung-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.969-974
    • /
    • 2008
  • As the railway becomes higher, the reliable stability and riding comfort of higher railway are required. To improve the riding comfort of high-speed trains, it is very helpful to use active suspension system for railway. In Japan, the high-speed train, Shinkansen has adopted semi-active suspension system and now it is running in the main trunk. In this paper, the authors introduce several technical trends of vibration control methods of Japanese Shinkansen. And the installation of semi-active suspension to HSR 350x and the test result of test run on the Kyoung-Bu high speed ling are also explained. After development of HSR 350x, new R&D national project of high speed train is progressed by Ministry of Land, Transport, and Maritime Affairs. This project is the development of Electric Multiple Unit of high speed train with 400km/h of maximum test speed. These result would be helpful to progress next generation high speed project.

  • PDF

A Study on a Measurement Scheme for the Development Goals of the Next Generation EMU (차세대전동차 개발목표에 대한 계량화 방안연구)

  • Oh, Seh-Chan;Park, Sung-Hyuk;Kim, Gil-Dong
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.713-720
    • /
    • 2009
  • The development goals of the next generation EMU are to improve the system maintainability, transportation capacity, reliability, passenger service and energy efficiency. In this paper, we propose a measurement scheme for the development goals of the next generation Electric Multiple Unit(EMU). To achieve that, we drew meaningful characteristics for each development goal, which mainly affect effectiveness and performance of vehicle system. Finally, the measurement scheme for the development is obtained by using the characteristics, which could be a numerical values such as maximum velocity, acceleration of the vehicle and so on or subjective values such as a results of surveys from passengers and so on. We expect the proposed measurement scheme will be used to measure the development goals of other similar system as well as the next generation EMU.

  • PDF

Investigation of Source Modelling for External Noise Prediction of Railway Vehicles (철도차량 외부소음 예측을 위한 음원모델에 관한 고찰)

  • Kim, Jong-Nyeun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1069-1077
    • /
    • 2009
  • For external noise prediction of railway vehicles, sophisticated individual source modelling as well as appropriate noise propagation model from the sources is necessary to ensure the accuracy of the predicted results and contributions of each equipment to the overall noise levels. Accurate and reasonable identification procedures of sound sources of equipment including source strength, directivity and positions installed in the train play an important role in a prediction model, since it is not easy to establish a simple model for the sources with a single rule due to the complexity of source characteristics of equipment in size and directivity pattern. This paper guidelines practical considerations for identification of noise sources in railway vehicles including typical source characteristics of several sub-systems that emits noise to the environment, particularly for electric multiple unit(EMU), and verify effectiveness of assumptions used in the modelling of equipment by measurement with a simple part. The predicted external noise level of a complete train using Exnoise, which was developed by Hyundai-Rotem and has been verified in the a lot of field-tests, incorporating source modelling considered in this paper shows close correlation with the measured ones.

  • PDF

Estimation of Curving Performance and Running Safety of Gwangju Electric Multiple Unit for City Subway (광주도시철도 전동차의 곡선추종성 및 주행안전성 평가)

  • Ham, Young-Sam;Oh, Taek-Yul
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.745-750
    • /
    • 2004
  • For the safety of railway, it should be evaluated for the running safety by measuring the derailment coefficient. Although railway has run the fixed and maintained rail, some of railway is derailed. This report shows the results that performed the static load test, wheelset manufacturing for test, main line running test on the basis of the derailment theory and experience. It is executed main line test into more than 80km/h for estimating the curving performance and running safety of Gwangju EMU. As the test results, could confirm the curving performance and running safety of Gwangju EMU from the results of the wheel unloading, lateral force, derailment coefficient etc. Derailment coefficient was less than 0.8, and lateral force allowance limit and wheel load reduction ratio were enough safe.

  • PDF

Properties of Thermal Performance on Stator Coil of Traction Motor by Accelerated Test (견인전동기 고정자 코일의 열적 열화특성)

  • Park Hyun-June;Lee Chang-Moo;Lee Han-Min;Jang Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.606-610
    • /
    • 2003
  • The 200 class insulation system which adopted to traction motor have excellent dielectric strength but weaken to thermal stress therefore deterioration phenomena analysis according to thermal stress is necessary. Accelerated thermal aging tests have been used to determine thermal reliability of stator coils used as traction motor in electric multiple unit. The conventional aging test is carried on according to IEC 60034-18-31 and IEEE Std. 275-1992. Variation in insulation resistance, P.I, capacitance, dielectric loss($tan{\delta}$) and partial discharge are measured during the aging cycle. Sample coils for traction motor were tested by accelerated aging test which composed of heat, vibration and moisture. Reliability and expected life were evaluated on the insulation system for traction motor.

  • PDF

Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated Test (견인전동기 고정자 코일의 전기적 열화특성)

  • Park Hyun-June;Jang Dong-Uk;Kim Gil-Dong
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.623-627
    • /
    • 2003
  • Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the severity of the stresses. The electrical aging by transient surge is very important to traction motor in EMU(electric multiple unit). This paper presents the insulation characteristics of stator coil by transient surge from inverter. There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of leakage current, dielectric loss($tan{\delta}$), capacitance, polarization index(PI) and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor in EMU.

  • PDF

Optimal Operation for Minimizing Energy Consumption in Electric Multiple Unit (전동열차의 주행에너지 소비를 최소화하는 최적운전)

  • 김치태;김동환;한성호;박영일
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.431-436
    • /
    • 2002
  • Train driving should be satisfied to run fixed distance within given time, and it is desirable to minimize energy consumption. Minimizing energy consumption depends on the train operation modes by driver or automatic operation. In this article, an optimal operation to minimize energy consumption by changing modes of train operation by a driver is investigated. First, powering model, braking model and consumed energy calculation model are introduced by using Matlab software. The accuracy of the model established by simulation is compared with the real experimental data, which is obtained from an authorized institution. Second, several simulations under a variety of operations in the ideal track are executed, and then the optimal pattern of train driving is found.

  • PDF

A study on passive safety regulations of Korean standard urban train (도시철도 차량의 충돌안전 기준에 관한 연구)

  • 구정서;노규석;조현직;권태수;최성규
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.645-651
    • /
    • 2000
  • In this paper, numerically evaluated is the regulations for crashworthy design of the Korean standard urban train suggested by KRRI. The 4-car consist of K-EMU(Korean Electric Multiple Unit) train developed in recent is analyzed under various collision conditions such as normal coupling, heavy shunt, light and heavy collisions. The collision conditions are assumed as K-EMU collides against another stationary one at 5 kph, 10 kph, 25 kph and 32 kph. According to the numerical results and bibliographical study, it is necessary that the regulations by KRRI be complemented from crashworthy point of view. Furthermore, the K-EMU train is recommended to adopt a new coupler with an additional energy absorber or a mechanical fuse.

  • PDF

The study for Resolution of flicker problems in Electric Multiple Unit fluorescent lamp (전동차 형광등 시스템의 플리커 문제 해결방안에 관한 연구)

  • Cho, Yun-Ok;Lee, Sang-Soo;Park, Chan-Woo
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1477-1482
    • /
    • 2006
  • 플리커란 형광등의 광 출력 변동폭이 큼으로 인해 인간의 눈과 뇌로 이루어진 감각시스템이 불유쾌한 감각을 인지하는 현상이다. 이러한 플리커 현상에 대한 저감 및 감소 대책이 미흡한 실정이며, 인간의 인지 능력 향상을 위해 플리커 문제 해결방안에 대한 연구 수행이 필요하다. 본 논문에서는 플리커를 감소시키기 위한 방법으로 정전력 단권 변압기 회로를 이용한 안정기 적용 방법을 제시하였다. 이 방법은 형상시스템의 전압원이 가변되더라도 형광등에 인가되는 전압을 허용범위 내에서 제어함으로 감소시킬 수 있다. 플리커 현상을 감소시키기 위하여 정전력 단권 변압기 회로를 이용한 안정기 적용법과, 전자식 안정기의 적용법을 제시하였으며, 본 연구에서 제시한 방법을 사용한다면 허용 한계 및 그 이하로 감소시킬 수 있을 것이며, 이를 이용한 장치를 사용하는 곳에서는 인간의 인지 능력을 향상 시킬 수 있을 것으로 사료된다.