• 제목/요약/키워드: Electric Heater

검색결과 261건 처리시간 0.029초

연료전지 자동차용 수소센서의 히터 조건에 따른 열전달 특성에 관한 연구 (Study on Heat Transfer Characteristics by Heater Conditions of Hydrogen Sensor for Fuel Cell Electric Vehicle)

  • 서호철;박경석
    • 한국자동차공학회논문집
    • /
    • 제21권1호
    • /
    • pp.23-29
    • /
    • 2013
  • In recent years, development of energy conversion systems using hydrogen as an energy source has been accelerated globally. Even though hydrogen is an environment-friendly energy source, safety and effectiveness issues in storage, transportation, and usage of hydrogen should be clearly resolved in every application. Therefore, sensors for detecting hydrogen leakage, especially for fuel cell electric vehicles, should be designed to have much higher resolution and accuracy in comparison with conventional gas sensors. In this study, we conducted to determine the design parameters for the semiconductor hydrogen sensor with optimized sensing conditions under the thermal distribution characteristic and thermal transfer characteristic. The heat generation study on power supply voltage was studied for correlation analysis of thermal energy according to the power supply voltage variation from 1.0 voltage to 10.0 voltage every 0.5 voltage. And we studied for the temperature coefficient of resistance with hydrogen sensor.

저압배선계통에서 직렬아크의 검출에 관한 연구 (A Study on the Series Arc Detection in Low-voltage Wiring Systems)

  • 김일권;박대원;최수연;박찬용;김황국;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.182-187
    • /
    • 2008
  • This paper dealt with the detection algorithm of series arcing, which is a cause of electric fires in low-voltage wiring systems. To find the distinguished electrical features of series arc, we simulated series arcing by the arc generator specified in UL1699. An electric heater, an inverter-controlled vacuum cleaner, and a phase-controlled incandescent lamp were used as loads to generate series arcing. A high-pass filter (HPF) with the low cut-off frequency of 3 kHz at -3 dB was fabricated and applied to separate the series arc signal from the AC voltage source. The experiment showed that the high frequency signal generates randomly during series arcing, and the phase-controlled incandescent lamp produces high frequency pulses even in normal state. In this case, the magnitude, the width, and the randomness of high frequency signal should be analyzed to estimate series arcing precisely.

Chiller용 냉매 CFC-11과 대체냉매 HCFC-123의 전기장을 사용한 핵비등 열전달 촉진에 관한 연구 (An Experimental Study of Nucleate Boiling Heat Transfer With EHD Technique in CFC-11 and HCFC-123)

  • 곽태희;김주형;정동수;김종보;차태우;한창섭
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.365-379
    • /
    • 1994
  • Pool boiling experiments were carried out to study the effect of electric field on nucleate boiling heat transfer. CFC-11 and its alternative HCFC-123 were used as working fluids. Boiling on both single tube and a bundle of five tubes was investigated. Heat flux varied from 5 to $25kW/m^2$ while the applied voltage changed from 0 to 1kV. The results showed that at low heat flux where boiling was not present or very weak, electric field-induced forced convection helped increase the heat transfer coefficients of CFC-11 and HCFC-123 significantly(4-15 times increase). However, at higher heat flux, nucleate boiling of CFC-11 which is a highly dielectric fluid, was not affected significantly by the application of electric field. In contrast to CFC-11, even at high heat flux, nucleate boiling of CFC-11 which has a relatively larger electric conductivity than CFC-11, was vigorously increased up to 2-4 times. The additional power required to apply the electric field was 1-2% of the total power consumption by the heater. The increase in overall heat transfer coefficient of evaporators with HCFC -123 was about 40%, suggesting a considerable reduction in evaporator size with EHD technique.

  • PDF

전기가열장치를 이용한 연약지반개량 (Improvement of Soft Ground using Electric Heating Equipment)

  • 한희수;임은상;이금성;장동훈
    • 한국지반환경공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.5-12
    • /
    • 2014
  • 본 논문은 심층연약지반 개량용 전기가열장치를 개발하여 경기도 화성시 인근 연약지반에 적용한 것이다. m당 1 kW의 전기를 소비하는 니켈-크롬선으로 구성된 길이 4.0 m의 전기가열장치를 지표하 3.5~6.5 m 사이에 설치하여 48시간의 지반가열을 2회, 총 96시간 실시하였으며, 온도계와 압력계를 지표하 5.0 m 지점에 매설하여 지반가열에 의한 온도 및 증기압 변화를 측정하였다. 실험결과 가열원으로부터 횡방향 거리의 온도분포 및 선단지지력의 변화는 이차함수를 나타내었으며, 둘 다 R2값은 1로 산정되었다. 또한, 전기가열로 인해 수증기가 배출됨에 따라, 함수비 및 간극수압이 감소함을 관찰할 수 있었다.

직렬아크에 대한 전류 및 전압 신호분석이 가능한 Monitoring Program 개발 (Development of Monitoring Program for Detecting Current and Voltage Signals for Series Arc)

  • 김두현;박종영;김성철;이종호
    • 한국안전학회지
    • /
    • 제25권2호
    • /
    • pp.29-34
    • /
    • 2010
  • This paper is aimed to develop monitoring software for detecting the characteristics of current and voltage signals for series arc on electric wire. In order to attain this purpose, the characteristics of series arc were analyzed by the current and voltage signals on electric wire which were installed, and also analyzed by the changes of RMS, instantaneous of waveform value in time domain and THD in frequency domain. Monitoring program which analyze the signal was developed by Labview which can analyze in time domain and frequency domain, and save data. Experimental setup for detecting verification of monitoring program was composed loads of a lamp, an electric heater and an electric fan loads which were usually using. Measurement points for detecting verification of monitoring program were selected at both the panel board and the arc generator at the same time. As results of the experiments by monitoring program, the arc current waveform showed the same characteristic in all measurement points of all load. But the arc voltage waveform was different in each measurement point. When arc occurred, the THD of current value increased above 20%. The results of this study will be effectively used in developing the preventive system of electric fire by series arc.

$\mu$SMES마그네트용 초전도도체의 안정성 및 퀀치 특성 (Stability and Quench Charcteristics of the SC Conductor for a $\mu$SMES Magnet)

  • 김해종;성기철;조전욱;권영길;류강식;최병주;류경우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.19-23
    • /
    • 2000
  • We are developing a small-sized superconducting magnetic energy storge ($\mu$SMES) magnet with the storage capacity of a few megajoules, which provides electric power with high quality to sensitive electric loads. A kA class superconductor with a high coppe $r^erconductor ratio was selected as a candidate conductor. The superconductor was tested in two points of view, which are basic and important in development of the $\mu$SMES magnet. First, stabilities of the superconductor against localized disturbances such as wire motions were estimated by using a wire heater. Second, the quench current characteristics for different charge rates were also tested. The stability data showed that the short heat pulses made the conductor more unstable. The superconductor had relatively high recovery currents ranging between 40% and 50% of its critical currents. The quench tests indicated that the quench currents of the conductor were independent of current ramp rates up to 3000 A/s and nearly equal to its cuitical current data.ta.

  • PDF

Emission Characteristics of Odors and Odorants Released from Grilling Mackerel and Pork Belly by Different Cooking Tools

  • Kim, Hyun-Jeong;Yu, Mee-Seon;Yang, Sung-Bong
    • 한국환경과학회지
    • /
    • 제23권10호
    • /
    • pp.1763-1773
    • /
    • 2014
  • It is known that mackerel and pork belly release a strong odor in the process of roasting. We evaluated a dilution factor of odor arising during roasting mackerel or pork belly and the relative odor strength using several cooking tools and analyzed compounds causing odors with gas chromatograph/mass detector. Roasting pans used were grill with lid, electric grill without lid and general roasting pan, and a grill with lid can attach the activated carbon charcoal deodorant at the inside of lid. And all electric grills have a drip tray under the heater. We investigated characteristics of odor emission depending on the presence of water and deodorants in these cooking tools. Study has shown that roasting mackerel produces approximately 36 time more odors than roasting pork belly, and the reduced odor emission when roast with water. And it shows the reduced deodorant effect when cooked with water after attaching activated carbon charcoal in the cooking pan. Major odor causing compounds arising when cooking mackerel and pork belly were aldehydes with high boiling point such as octyl aldehyde with a low odor threshold value.

고압축 폐열회수장치를 구비한 증기보일러에 관한 연구 (A study on the steam boiler with high compression waste heat recovery system)

  • 한규일;조동현
    • 수산해양기술연구
    • /
    • 제53권3호
    • /
    • pp.302-307
    • /
    • 2017
  • An electric steam boiler equipped with a condensate recovery system, which stores the condensate generated after using steam in steam washers, steam cookers, steam irons, and steam cleaners in a condensate tank and supplies compressed air to the condensate tank so that the condensate is recovered to the boiler by the pressure of the compressed air, was studied. In the results of this study, the heat energy balance between the quantity of the heat generated by the non-metallic surface heating element and the quantity of the heat absorbed by the water was good in a range of ${\pm}5%$. In addition, the heat transfer rate increased in proportion to the electric power of the surface heating element heater, the waste heat energy was normally recovered by the recovery of the condensate of the steam boiler equipped with the high compression waste heat recovery system, and the recovery rate of the waste heat exhibited 23%.

전기자동차용 히트펌프의 열 부하 조건에 따른 캐빈온도 특성 (Characteristic of Cabin Temperature According to Thermal Load Condition of Heat Pump for Electric Vehicle)

  • 박지수;한재영;김성수;유상석
    • 대한기계학회논문집B
    • /
    • 제40권2호
    • /
    • pp.85-91
    • /
    • 2016
  • 내연기관 자동차와 달리 전기자동차는 배터리 폐열이 부족하여 실내 난방을 위해 추가적으로 PTC 히터를 사용하고 있지만 전력소모가 큰 단점이 있다. 최근 이러한 단점을 보완할 수 있는 히트펌프 적용에 관한 연구가 활발히 진행되고 있다. 본 연구에서는 히트펌프의 운전특성 해석을 위해 MATLAB/SIMULINK$^{(R)}$환경에서 R134a 히트펌프 모델과 캐빈 모델을 개발하였다. 모델은 여름과 겨울에서 히트펌프의 작동 특성에 따른 실내 온도변화를 나타낼 수 있으며, 모델 검증은 구성품 수준에서 응축기와 증발기의 용량 비교를 수행하였다. 또한 동일한 냉방조건에서 캐빈온도 변화 비교를 통해 캐빈 모델을 검증하였다. 해석 결과 전동압축기 소비전력은 모든 외기온도 조건에서 PTC 히터 보다 낮은 것으로 나타났다. 또한 영하조건에서 히트펌프의 난방용량이 부족한 현상에 대해 폐열회수를 적용하여 효율적인 난방 작동을 할 수 있는 조건을 분석하였다.

온실설비 작동용 태양광발전시스템의 발전 성능 분석 (Power Generating Performance of Photovoltaic Power System for Greenhouse Equipment Operation)

  • 윤용철;배용한;유영선;이성현;서원명
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.177-184
    • /
    • 2009
  • 본 연구는 온실 운영에 필요한 전력량을 확보함으로서 온실경영비 절감을 목적으로 우선 태양광발전시스템을 온실의 인접한 건물의 옥상에 설치하여 기상상태에 따른 발전량을 실험적으로 검토하였다. 연구결과를 요약하면 다음과 같다. 실험기간 동안 최고, 평균 및 최저온도는 각각 $0.4{\sim}34.1,\;-6.1{\sim}22.2$$-14.1{\sim}16.7^{\circ}C$ 정도의 범위에 있었다. 그리고 일사량의 경우, 최대, 평균 및 최저값은 각각 $28.8MJ{\cdot}m^{-2}$, $14.9MJ{\cdot}m^{-2}$$0.6MJ{\cdot}m^{-2}$ 정도였고, 전력은 일사량에 비례해서 증가하지 않고 약 750W 전후에서 거의 일정한 것을 알 수 있었다. 일일 최대, 평균 및 최소 소비전력량은 각각 약 5.2kWh, 2.5kWh및 0kWh정도였다. 본 실험에 사용된 시스템의 평균 소비전력량을 기준으로 보면, 온풍기의 용량 및 작동시간이 작은 경우는 충분하지만 큰 경우는 부족한 것으로 나타났다. 온풍기의 용량이 큰 경우, 어레이 면적이 현재의 약 3배인 약 $21m^2$ 정도이면 평균 전력량으로 충분할 것으로 판단되었다. 물론 어레이의 온도가 높아지는 한 여름철에는 일사량에 비례해서 발생 전력이 증가하지 않은 것으로 나타났지만, 현재까지 실험결과로 보면, 두 인자간에 상관계수가 0.84 정도로 상관관계가 높은 것으로 나타났다.