DOI QR코드

DOI QR Code

A study on the steam boiler with high compression waste heat recovery system

고압축 폐열회수장치를 구비한 증기보일러에 관한 연구

  • HAN, Kyu-il (Department of Mechanical System Engineering, Pukyong National University) ;
  • CHO, Dong-Hyun (Department of Computer Aided Mechanical Engineering, Daejin University)
  • 한규일 (부경대학교 기계시스템공학과) ;
  • 조동현 (대진대학교 컴퓨터응용기계공학과)
  • Received : 2017.07.18
  • Accepted : 2017.08.29
  • Published : 2017.08.31

Abstract

An electric steam boiler equipped with a condensate recovery system, which stores the condensate generated after using steam in steam washers, steam cookers, steam irons, and steam cleaners in a condensate tank and supplies compressed air to the condensate tank so that the condensate is recovered to the boiler by the pressure of the compressed air, was studied. In the results of this study, the heat energy balance between the quantity of the heat generated by the non-metallic surface heating element and the quantity of the heat absorbed by the water was good in a range of ${\pm}5%$. In addition, the heat transfer rate increased in proportion to the electric power of the surface heating element heater, the waste heat energy was normally recovered by the recovery of the condensate of the steam boiler equipped with the high compression waste heat recovery system, and the recovery rate of the waste heat exhibited 23%.

Keywords

References

  1. Karl S and Hein A. 1981. Correlations for nucleate boiling heat transfer in forced convection. Int J Heat Mass Transfer 24, 99-107. https://doi.org/10.1016/0017-9310(81)90097-1
  2. Liao Q and Xin MD. 2000. Augmentation of convective heat transfer inside tubes with three-dimensional internal extended surfaces and twisted-tape inserts. Chemical Engineering Journal 78, 95-105. (DOI:10.1016/S1385-8947(00)00134-0)
  3. Yu BH, Kum SM, Lee CE and Lee SR. 2013. Study on the combustion characteristics of premixed combustion system with exhaust gas recirculation. Energy 61, 345-353. (DOI:10.1016/j.energy.2013.08.057)
  4. Han JW and Kee CE. 2002. Numerical study on flame structure and NO formation characteristics in oxidizer-controlled diffusion flames. Transactions of the KSME B 25(5), 742-749.
  5. Knaani A and Zvirin Y. 1994. Bifurcation phenomena in two-phase natural circulation, Int J Multiphase Flow 19(6), 1129-1151. https://doi.org/10.1016/0301-9322(93)90081-5
  6. Chen KS and Chang YR. 1988. Steady-state analysis of two-phase natural circulation loop. Int J Heat Mass Transfer 31(5), 931-940. https://doi.org/10.1016/0017-9310(88)90082-8
  7. Faghri A, Chen MM and Morgon M. 1989. Heat transfer characteristics in two-phase closed conventional and concentric annular thermosyphons. ASME J of Heat Transfer 111, 611-618. https://doi.org/10.1115/1.3250726
  8. Hallanger and Erling C. 1980. Design principles of boiler optimization. ASHARE J. 22(5), 28-31.
  9. Annaratone and Donatello. 1977. Investigation on optimizing the water tube boiler design for the production of saturated steam. Termotecnica, 31(4) 204-210.
  10. Chang SY and Shen YT. 1987. Integral optimization of small-size industrial boiler. Power Engineering 5, 24-30.
  11. Kum KB. 2016. The thermal efficiency and pollutant emissions characteristics of condensed water recirculation waste heat recovery condensing boiler. Master's degree in engineering, 27-29.