• Title/Summary/Keyword: Electric Erosion

Search Result 39, Processing Time 0.023 seconds

Application of Optical Method for Quantitative Investigation of MgO Erosion in AC-PDP

  • Choi, Seung-Ho;Lee, Soon-Il;Oh, Soo-Ghee;SunWoo, Jin-Ho;Kim, Jae-Gak;Lee, Gol-Hee;Kim, June-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.185-186
    • /
    • 2000
  • For the quantitative investigation of the erosion of MgO layers in real ac-PDP cells, we constructed a microscopic spectrophotometer which is capable of measuring transmission spectra from the area as small as 20 ${\times}$ 20 ${\mu}m^2$. In the test on the sputtered MgO films with a thickness gradient, we were able to probe the thickness variation of 1000 nm over $1000-{\mu}m$ distance. Using this instrument, we were able to determine not only the erosion rate at the particular position of ac-PDP cells but also the relative erosion rate at different positions in a single ac-PDP cell.

  • PDF

Influence of Current Waveform on Anode Erosion in Wire Electric Discharge Machining (와이어 방전가공에서 전류파형이 양극침식에 미치는 영향)

  • Cho, Sung-San;Oh, Jin-Hyuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.7
    • /
    • pp.127-133
    • /
    • 2001
  • The effects of triangular and rectangular discharge current waveforms on anode erosion in wire electric discharge machining is investigated based on heat transfer analysis of half-space subject to time and space-dependent heat flux. The thermal load on the anode is simulated by a hear flux that is calculated from time-dependent discharge channel radius and energy. Evolution of the melting front during discharge, the molten volume at the experimental result for qualitative verification of the analysis. It is demonstrated that the triangular current waveform is more efficient in eroding the anode than the rectangular one.

  • PDF

Premature Failure Analysis of Servovalve Components for a Thermal Power Plant

  • Chang, Sung-Yong;Chang, Joong-Chel;Kim, Bum-Soo;Seo, Min-Woo;Choi, Chel-Jong
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.9
    • /
    • pp.708-714
    • /
    • 2011
  • The premature failure of a servovalve used for six months in a thermal power plant has been analyzed. The servovalve was made of stainless steel, containing 16Cr-0.44Mo, along with other elements. An overload of oil-supply pumping and an abnormal increase in the oil flux were observed during operation. A study revealed that erosion and corrosion could be the main causes of the failure. The visual examination of the servovalve did not show any appreciable damage. However, corrosion and erosion of the servovalve were observed using scanning electron microscopy (SEM). Upon examination of the servovalve, the corrosion was found to have occurred throughout the bushing and spool; however, erosion occurred at only the edge-side. In addition, the condition of the electrohydraulic control system (EHC) oil was investigated with respect to its satisfaction of the management standard.

Development of Inspection Methodology for a Nuclear Piping Wall Thinning Caused by Erosion Using Ultrasonic B-Scan Measurement Device (B-Scan 초음파 측정장비를 이용한 원전 배관 침식손상 검사법 개발)

  • Lee, Dae Young;Suh, Heok Ki;Hwang, Kyeong Mo
    • Corrosion Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.89-95
    • /
    • 2012
  • U.S. Electric Power Research Institute (EPRI) has developed CHECWORKS program and applied it to power plant piping lines since some lines were ruptured by flow-accelerated corrosion (FAC) in 1978. Nowadays the CHECWORKS program has been used to manage pipe wall thinning phenomena caused by FAC. However, various erosion mechanisms can occur in carbon-steel piping. Most common forms of erosion are cavitation, flashing, liquid droplet impingement erosion (LDIE), and Solid Particle Erosion (SPE). Those erosion mechanisms cause pipe wall thinning, leaking, rupturing, and even result in unplanned shutdowns of utilities. Especially, in two phase condition, LDIE damages a wide scope of plant pipelines. Furthermore, LDIE is the major culprit to cause such as power runback by pipe leaking. This paper describes the methodologies that manage wall thinning and also predict LDIE wall thinning area. For this study, current properties of two-phase condition are investigated and LDIE areas are selected. The areas are checked by B-Scan method to detect the effect of wall thinning phenomena.

Characteristics of Cavitation-Erosion Damage with Amplitude in Seawater of 5052-O Al Alloy for Ship (선박용 5052-O 알루미늄 합금의 해수 내 진폭 변수에 따른 캐비테이션-침식 손상 특성)

  • Yang, Ye-Jin;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.239-249
    • /
    • 2020
  • The characteristics of cavitation-erosion damage with changes in the amplitude of 5052-O aluminum alloy for ships were investigated in a seawater environment. In the cavitation-erosion experiment, the cavitation environment was created using a vibration-generating device with a piezo-electric effect. The amplitudes of 5 ㎛, 10 ㎛, and 30 ㎛ were created by changing the geometric shape of the cavitation horn. The resistance characteristics of cavitation-erosion damage were evaluated by weight loss and pitting area. The damaged surface was analyzed using scanning electron microscopy (SEM) and 3D optical microscopy. As the amplitude increased, the amount of damage and the area of the damaged surface increased, and the damage was concentrated at the center and edge of the specimen. The pit was created after the initial incubation period with increasing experimental time, and then the pits were merged to grow and propagate into craters, and eventually, the surface was detached and damaged. The cavitation-erosion damage after 30 minutes with amplitude of 10 ㎛ and 30 ㎛ was 1.48 and 2.21 times compared to 5 ㎛, respectively.

Study on the Cavitation Damage of Cupronickel(70/30) Tube for Gas Absorption Refrigeration Machine

  • Lim, Uh-Joh;Jeong, Ki-Cheol;Yun, Byoung-Du
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.332-337
    • /
    • 2004
  • The use of gas absorption refrigeration machine has considerably increased because of the shortage of the electric power in the summer and the regulation of freon refrigerant. Gas absorption refrigeration machine consists of a condenser, a heat exchanger. supplying pipes, a radiator etc, This system is likely to be corroded by acid. dissolved oxygen and gases, Cavitation erosion-corrosion by flow velocity of cooling water may happen in absorption refrigeration machine. In these cases. erosion and corrosion occur simultaneously. Then, it makes a serious damage with synergy effect. Therefore, this paper was studied on the cavitation damage of cupronickel(70/30) tube for gas absorption refrigeration machine, In the $30^{\circ}C$ tap water, linear polarization test and anodic polarization test were carried out for copper(C1220T-OL) and cupronickel(70/30) tube. Also, cavitation erosion-corrosion behavior of cupronickel (70/30) tube was considered, The main results are as following: (1) In the linear test, the corrosion current density of cupronickel(70/30) is higher than that of copper. (2) The erosion-corrosion rate of cupronickel(70/30) displayed later tendency than that of copper by vibratory cavitation in cooling water. (3) In cooling water, the progress mechanism of erosion-corrosion rate of copper and cupronickel(70/30) follows a pattern of incubation, acceleration, attenuation and a steady state period.

The Analysis of Temperature and Electric Field due to Contact Failure in Power Substation (수변전설비에서 접점 불량에 따른 열 및 전계 분포 해석)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.307-311
    • /
    • 2016
  • Although there are existing Residual Current Protective Device (RCD) including detect electric leakage and elements such as short circuit and surge, the occurrence of incidents caused by electric faults, including fire, are still constant. The purpose of this study is to analyze the causes of accidents through the electric field distribution in the interpretation of the fault contact breaker. Simulation results by the arc fault has shown the convergence of temperature and electric field to the defect. Through their simulation results, the main cause of erosion phenomena in circuit breaker bar is the electric arc by concentration of electric field not due to dissolve by temperature.

A Characteristic of Tracking Progress Happened at the End of the VCTFK (VCTFK 끝단에서 발생되는 트래킹의 진전특성)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Ok, Kyung-Gea;Lee, Chun-Ha;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.78-83
    • /
    • 2010
  • This paper describes the characteristic of tracking progress happened at the end of the polyvinyl chloride insulated cabtyre oval cord(VCTFK) that is widely used for distribution cord. Tracking is occurred owing to the drop of electrolyte at the end of the VCTFK. The tracking progress and its characteristic happened at the end of the VCTFK are as follow; Carbonization and electrical erosion are happened at the end of the VCTFK. Electrical erosion is begun at the insulation layer near conductors. After that, it is also happened at the sheath layer. Accumulation of carbonized insulation and sheath materials at the end of the VCTFK is begun after progress of electrical erosion. When the accumulation is progressed arc discharge is appeared and finally it goes to tracking breakdown.

Seoul World Cup Stadium Electric Plan (서울월드컵경기장 전기설계)

  • 최용민
    • Journal of the Korean Professional Engineers Association
    • /
    • v.34 no.5
    • /
    • pp.40-43
    • /
    • 2001
  • In order for the World cup football game to be operated stably with duplicate service electric power supply, It is done, emergency generator and the U.P.S it establishes. the electric power system power control, lighting control, integrated monitoring. rue fighting. obstruction light, the searchlight, snow melting, electric erosion shield. grounding, the lightening protection and viewable lighting, stadium floodlight and an electric bulletin board it composed of the back which it sells.

  • PDF

Analysis of Influence on Stream Water Quality by Soil Erosion Control Structures (사방공작물이 계류수질에 미치는 영향 분석)

  • Park, Jae-Hyeon;Kim, Choonsig
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.4
    • /
    • pp.571-577
    • /
    • 2013
  • This study was carried out to establish the construction guidelines of soil erosion control structures for a restoration of mountain stream with analysis of water quality around constructed soil erosion control structures in mountain streams. Water pH of the Uidong valleys in Bukhansan (Mt.) was similar between the constructed soil erosion control structures of lower stream areas [pH 6.53(6.25~6.82)] and the non-constructed areas of upper stream areas [pH 6.32(5.73~6.90)]. Mean concentration of dissolved oxygen was also similar between the constructed soil erosion control structures of lower steam areas [10.2 mg/L(9.9~10.4 mg/L)] and the non-constructed areas of upper stream areas [10.3 mg/L (9.6~10.6 mg/L)]. Mean electric conductivity was similar between the lower [$63.9{\mu}S/cm$ ($32.6{\sim}120.4{\mu}S/cm$)]a nd the upper stream areas [$62.2{\mu}S/cm$ ($40.3{\sim}89.5{\mu}S/cm$)]. Mean concentration of anions was also similar between the lower [15.94 mg/L (3.43~7.98 mg/L)] and the upper stream areas [14.51 mg/L (2.56~4.29 mg/L)]. Water pH of the Honggei valleys in Sancheong-gun was similar between the lower [pH 6.86(6.50~7.10)] and the upper stream areas [pH 6.89(6.61~7.12)]. Mean concentration of dissolved oxygen was also similar between the lower [11.9 mg/L(11.5~12.3 mg/L)] and the upper stream areas [12.2 mg/L (11.6~12.6 mg/L)]. Mean electric conductivity was similar between the lower [$633.4{\mu}S/cm$ ($31.6{\sim}34.6{\mu}S/cm$)] and the upper stream areas [$32.7{\mu}S/cm$ ($31.4{\sim}34.3{\mu}S/cm$)]. Mean concentration of anion was also similar to both stream areas [1.0 mg/L (0.1~2.2 mg/L)]. Water quality in the Uidong and the Honggei valleys was not significantly different between the constructed soil erosion control structures of lower stream areas and the non-constructed areas of upper stream areas. It will be needed to study the time-series analysis of water quality before and after the construction of soil erosion control structure the restoration of mountain streams because the water quality in mountain streams could be affected during the construction processes of structures.