• Title/Summary/Keyword: Electric Discharge Machining

Search Result 96, Processing Time 0.027 seconds

Inspection of Heat Exchanger Tubing Defects with Ultrasonic Guided Waves (유도초음파를 이용한 열 교환기 튜브 결함 탐상)

  • Shin, Hyeon-Jae;Rose, Joseph L.;Song, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • This study shows the defect detection and sizing capability of ultrasonic guided waves in the nondestructive inspection of heat exchanger and steam generator tubing. Phase and group velocity dispersion curves for the longitudinal and flexural modes of a sample Inconel tube were presented for the theoretical analysis. EDM(Electric Discharge Machining) wears in tubing under a tube support plate and circumferential laser notches in tubing were detected by an axisymmetric and a non-axisymmetric transducer set up, respectively. EDM wears were detected with L(0, 2), L(0, 3) and L(0, 4) modes and among them L(0, 4) mode was found to be the most sensitive. It was also found that the flexural modes around L(0, 1) mode could be used for the detection and sizing of laser notches in the tubing.

  • PDF

Problems and Solutions for Ultra-compact LED Package Development (극소형 LED 패키지 개발의 문제점과 해결 방안)

  • Lee, Jong Chan
    • Journal of Industrial Convergence
    • /
    • v.17 no.4
    • /
    • pp.9-14
    • /
    • 2019
  • This paper presents several problems that can occur in the development of the ultra-compact LED package of less than 1.0mm and introduces the solution to them. In the existing mold structure, since the upper and lower core parts are integrated, various errors have occurred due to the roughness of EDM in the small model, which is a limiting factor in further reducing the mold size. As a countermeasure, the prefabricated model was presented in an earlier study to overcome the obstacles to the development of a ultra-compact LED package. In this paper, several problems have been found during the fabrication of prototypes as a starting work to produce the results for the presented model. The types are suggested and the solutions are discussed. And by changing the existing 2-row structure to 3-row structure in the same size lead frame, the aspect of efficient production is considered. The experimental procedure verifies the proposed solution and conducts a test to produce a prototype to confirm that a good product can be produced.

Signal Characteristics of Eddy Current Test for Intergranular Attack of Steam Generator Tubes (증기발생기 전열관의 입계부식에 대한 와전류검사 신호특성)

  • Choi, Myung-Sik;Lee, Deok-Hyun;Cho, Se-Gon;Yim, Chang-Jae;Han, Jung-Ho;Hur, Do-Haeng
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.198-202
    • /
    • 2002
  • Beacuse intergranular attack (IGA), one of the locallized corrosion forms occurring on steam generator tubes, can not be fabricated by an electric discharge machining method, there are few data for the eddy current test (ECT) characteristics of IGA. In this paper, the characteristics of eddy current signals are evaluated using nonexpanded tubes with IGA defects formed in 0.1 M sodium tetrathionate solution at $40^{\circ}C$. The detectability and sizing accuracy of IGA were discussed in terms of the coil type and frequency of the ECT probes.

A Research on Lengthening the Life of Warm Forging Die (온간단조금형의 수명연장에 관한 연구)

  • Kim, Sei-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2010
  • Rotor pole for AC(alternating current) generator is manufactured through transfer warm forging die. As soon as the material is heated at the warm manufacturing process, it is transferred to the first stage for upsetting work and then to the second stage for lateral extrusion work. The processes at the lateral extrusion work such as die block, die bushing, center punch, and side punch make severe condition and abrasion which leads to shorten the die life. This causes production decrease, long maintenance time, and low level of precision. Research on the die material selection, heat process cycle improvement, electric discharge machining trouble solution, and re-construction of main parts is expected to find a method to lengthen the die life up to 40 - 50%.

Residual Stress Analysis of New Rails Using Contour Method (굴곡측정법을 이용한 신 레일의 잔류응력 분석)

  • Song, Min Ji;Choi, Wookjin;Lim, Nam-Hyoung;Kim, Dongkyu;Woo, Wanchuck;Lee, Soo Yeol
    • Journal of The Korean Society For Urban Railway
    • /
    • v.6 no.4
    • /
    • pp.393-399
    • /
    • 2018
  • It is well recognized that residual stresses of the rails, generated from the manufacturing process including roller straightening and heat treatment, play an important role in determining fatigue and fracture properties of the rails. Thus, it has been a challenge to measure the residual stresses accurately. In this work, contour method was employed to evaluate the residual stresses existing in interior of the rails. The cross section perpendicular to the longitudinal direction of the rail was cut at a very slow rate using electric discharge machining (EDM), after which a laser-based flexural measuring instrument enabled us to precisely measure the flection of the cross section. The measured data were converted into the residual stresses using the commercial finite element package, ABAQUS, through a user-defined element (UEL) subroutine, and the residual stresses of the new rails (50N, KR60, UIC60) with three different specifications were compared.

Quantitative EC Signal Analysis on the Axial Notch Cracks of the SG Tubes (SG Tube 축방향 노치 균열의 정량적 EC 신호평가)

  • Min, Kyong-Mahn;Park, Jung-Am;Shin, Ki-Seok;Kim, In-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.374-382
    • /
    • 2009
  • Steam generator(SG) tube, as a barrier isolating primary to the secondary coolant system of nuclear power plants(NPP), must maintain the structural integrity far the public safety and its efficient power generation capacity. And SG tubes bearing defects must be timely detected and taken repair measures if needed. For the accomplishment of these objectives, SG tubes have been periodically examined by eddy current testing(ECT) on the basis of administrative notices and intensified SG management program(SGMP). Stress corrosion cracking(SCC) on the SG tubes is not easily detected and even missed since it has lower signal amplitude and other disturbing factors against its detection. However once SCC is developed, that can cause detrimental affects to the SG tubes due to its rapid propagation rate. Accordingly SCC is categorized as prime damage mechanism challenging the soundness of the SG tubes. In this study, reproduced EDM notch specimens are examined for the detectability and quantitative characterization of the axial ODSCC by +PT MRPC probe, containing pancake, +PT and shielded pancake coils apart in a single plane around the circumference. The results of this study are assumed to be applicable fur providing key information of engineering evaluation of SCC and improvement of confidence level of ECT on SG tubes.