• Title/Summary/Keyword: Electric Current Consumption

Search Result 155, Processing Time 0.031 seconds

Electrical Properties and Far-infrared Ray Emission of Ceramics Manufactured with Sawdust and Rice Husk (톱밥과 왕겨로 제조된 세라믹의 전기적 성질과 원적외선 방사특성)

  • Oh, Seung Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.106-112
    • /
    • 2016
  • This study investigated electrical properties and far-infrared ray emission according to the carbonizing temperature and phenol-formaldehyde (PF) resin impregnation ratio of ceramics manufactured using sawdust and rice husk. The far-infrared ray emission values and emission energy values decreased as the carbonizing temperature increased. The far-infrared ray emission values of the ceramics manufactured using a carbonizing process at $600^{\circ}C$ and a board with a PF resin impregnation ratio of 60 percent was 0.930; the emission energy presented the highest value of $4.32{\times}10w/m^2$. The electric resistance decreased as the carbonizing temperature increased. For the increase in the carbonizing temperature above $1200^{\circ}C$, ceramics was very close to a conductor due to the small resistance. The power consumption increased by the decrease of electric resistance and increase of the electric current in the case of a higher resin impregnation ratio.

Design of Self-Starting Hybrid Axial Flux Permanent Magnet Synchronous Motor Connected Directly to Line

  • Eker, Mustafa;Akar, Mehmet;Emeksiz, Cem;Dogan, Zafer;Fenercioglu, Ahmet
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1917-1926
    • /
    • 2018
  • In view of the current state of the reserves of electric energy generated resources and the share of electric motors in electricity consumption, many researches and studies related to efficiency in electric motors are being made. The presented work is related to the Axial Flux Permanent Magnet Synchronous Motor (AF-PMSM), which has recently undergone significant work based on the development of magnet and motor technology. In this study, a novel AF-PMSM was designed analytically through Finite Element Method (FEM) which can be started by connecting to a line such as an asynchronous motor in a transient state and can operate with high efficiency and power factor after synchronization in steady state without the need for an expensive motor drive. According to the obtained FEM results, a design with an efficiency class of IE4 of 5.5 kW shaft power, a 4 poles motor was obtained. As a result, economic calculations indicate that the extra cost of the designed Line start AF-PMSM with respect to the asynchronous motor is rapidly compensated by energy saving due to a more efficient operation, especially constant speed operations. As a result of the analysis obtained, the targeted values are reached. For induction motors and radial flux permanent magnet synchronous motors, a good alternative motor that can operate with high efficiency and power factor has been obtained.

Investigation of the Effect of Solution Acidity and Organic Additives on the Electrodeposition of Trivalent Chromium Ions (3가크롬 이온의 전착 반응에 용액 산도 및 유기물 첨가제가 미치는 영향 연구)

  • Lee, Joo-Yul;Van Phuong, Nguyen;Kang, Dae-Keun;Kim, Man;Kwon, Sik-Chol
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.6
    • /
    • pp.297-303
    • /
    • 2010
  • The effect of solution acidity and organic additives, polyethylene glycol (PEG), on the trivalent chromium electroplating was systematically investigated in the view point of electroreduction of trivalent chromium ions and solution stability. It was found that solution acidity controlled at pH 2.5 showed the widest current range for bright electrodeposits in the presence of PEG additives, which reduced the local current intensification at high current densities. Through complex interaction between PEG additives and hydrogen ion, that is, solution acidity, electrode potential was moved in the negative direction in the bulk solution, while it shifted in the positive when electric potential was scanned. In conjunction with electrochemical quartz crystal microbalance (EQCM), it was found that PEG additives had a role in promoting the electron transfer to trivalent chromium ion complexes in bulk solution and their adsorption at the electrode surface as well as interfering with hydrogen ion reduction process below pH 2.5. The PEG additives developed the nodular morphology during electroreduction of trivalent chromium ions with the increase of solution acidity and enhanced its current efficiency by maintaining the consumption of complexant, formic acid, at low speed.

Assessment of Theoretical Annual Energy Production in the Coast of South Korea Using Tidal Current Energy Converters Utilizing Flow Induced Vibration (한국 해안에서 유동유발진동 현상을 이용한 조류에너지 발전기술의 이론적 연간 발전량 산정연구)

  • Kim, Eun Soo;Oh, Kwang Myung;Park, Hongrae
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.65-72
    • /
    • 2019
  • The Korean government is aiming to produce 20% of the electricity using renewable energy sources by 2030. Ocean renewable energy sources which are abundant in South Korea can do an important role to achieve the goal. This paper introduces a tidal current energy converter utilizing flow induced vibrations which can efficiently work even in the currents slower than 1.0m/s and suggests optimal designs of the tidal energy converter based on speeds of the tidal currents in seven different coastal regions in South Korea. Moreover, the theoretical annual energy production by the tidal converter is estimated at theses costal areas. The total amount of the annual energy production by the tidal energy converter is predicted as 221.77 TWh which is equivalent to 42.3% of the electric consumption of South Korea in 2013. The result shows that the tidal current energy converter can be an important role to achieve the goal of the Korean government.

A Study on Energy Savings of a DC-based Variable Speed Power Generation System (직류기반 가변속 발전 시스템을 이용한 에너지 절감에 관한 연구)

  • Kido Park;Gilltae Roh;Kyunghwa Kim;Changjae Moon;Jongsu Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.666-671
    • /
    • 2023
  • As international environmental regulations on ship emissions are gradually strengthened, interest in electric propulsion and hybrid propulsion ships is increasing, and various solutions are being developed and applied to these ships, especially stabilization of the power system and system efficiency. The direct current distribution system is being applied as a way to increase the power. In addition, verification and testing of safety and performance of marine DC distribution systems is required. As a result of establishing a DC distribution test bed, verifying the performance of the DC distribution (variable speed power generation) system, and analyzing fuel consumption, this study applied a variable speed power generation system that is applied to DC power distribution for ships, and converted the power output from the generator into a rectifier. A system was developed to convert direct current power to connect to the system and monitor and control these devices. Through tests using this DC distribution system, the maximum voltage was 751.5V and the minimum voltage was 731.4V, and the voltage fluctuation rate was 2.7%, confirming that the voltage is stably supplied within 3%, and a variable speed power generation system was installed according to load fluctuations. When applied, it was confirmed through testing that fuel consumption could be reduced by more than 20% depending on the section compared to the existing constant speed power generation system.

A Study on Power LED driving constant Current-type DC-DC converter Driven using microcontroller (마이크로컨트롤러를 이용한 Power LED 구동용 정전류형 DC-DC컨버터 구동에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Choi, Gi-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1797-1805
    • /
    • 2012
  • In this paper, Power LED(Light Emitting Diodes) is studied to driver as a new lighting system in the spotlight, replacing a large existing lighting system with fluorescent and incandescent lighting. To take advantage a variety of DC power as the boost DC-DC converter design specifications through the inductor L and capacitor C through PSPICE to calculate the best estimate of the value. Converter's switching frequency is 50[kHz], the first Duty Rate was made to increase gradually depending on the value of the detection were, 10[%] in the output voltage. As a result, the simulated Boost Power LED driver characteristics is in comparison with the design specifications, 5[%] or less as the error was approximated. So, when input 15[V] were offered, a stable output 24[V] were obtained, and Dimming Control through the adjustment of brightness and current consumption were obtained to possible result.

A High Linear And Low Noise COMOS RF Front-End For 2.4GHz ZigBee Applications (지그비(ZigBee) 응용을 위한 고선형, 저잡음 2.4GHz CMOS RF 프론트-엔드(Front-End))

  • Lee, Seung-Min;Jung, Chun-Sik;Kim, Young-Jin;Baek, Dong-Hyun
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.604-610
    • /
    • 2008
  • A 2.4 GHz CMOS RF front-end using for ZigBee application is described The front-end consists of a low noise amplifier and a down-mixer and uses a 2 MHz IF frequency. A common source with resistive feedback and an inductive degeneration are adopted for a low noise amplifier, and a 20 dB gain control step is digitally controlled. A passive mixer for low current consumption is employed. The RF front-end is implemented in 0.18 ${\mu}m$IP6M CMOS process. The measured performance is 4.44 dB NF and -6.5 dBm IIP3 while consuming 3.28 mA current from a 1.8 V supply.

  • PDF

Influence of Sputtering Conditions on Properties of Copper Oxide Thin Films (스퍼터링 공정 조건이 산화 구리 박막 특성에 미치는 영향)

  • Cho, Jae Yu;Heo, Jaeyeong
    • Current Photovoltaic Research
    • /
    • v.5 no.1
    • /
    • pp.15-19
    • /
    • 2017
  • The fossil fuel power consumption generates $CO_2$, which causes the problems such as global warming. Also, the increase in energy consumption has accelerated the depletion of the fossil fuels, and renewable energy is attracting attention. Among the renewable energies, the solar energy gets a lot of attention as the infinite clean energy source. But, the supply level of solar cell is insignificant due to high cost of generation of electric power in comparison with fossil fuels. Thus several researchers are recently doing the research on ultra-low-cost solar cells. Also, $Cu_2O$ is one of the applied materials as an absorption layer in ultra-low-cost solar cells. Cuprous oxide ($Cu_2O$) is highly desirable semiconductor oxide for use in solar energy conversion due to its direct band gap ($E_g={\sim}2.1eV$) and a high absorption coefficient that absorbs visible light of wavelengths up to 650 nm. In addition, $Cu_2O$ has several advantages such as non-toxicity, low cost and can be prepared with simple and cheap methods on large scale. In this work, we fabricated the $Cu_2O$ thin films by reactive sputtering method. The films were deposited with a Cu target with variable parameters such as substrate temperature, rf-power, and annealing condition. Finally, we confirmed the structural properties of thin films by XRD and SEM.

Comparison of operational efficiency between sand-filtration process and membrane filtration process (모래여과 공정과 막여과 공정의 운영효율 비교)

  • Byeon, Kwangjin;Jang, Eunsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.529-537
    • /
    • 2017
  • Membrane filtration process is an advanced water treatment technology that has excellently removes turbidity and microorganisms. However, it is known that it has problems such as low economic efficiency and the operating stability. Therefore, this study was to evaluate on the economical feasibility and operational stability comparison of membrane and sand filtration process in Im-sil drinking water treatment plant. For the economic analysis of each process, the electricity cost and chemical consumption were compared. In the case of electric power consumption, electricity cost is $68.67KRW/m^3$ for sand filtration and $79.98KRW/m^3$ for membrane filtration, respectively. Therefore, membrane filtration process was about 16% higher than sand filtration process of electricity cost. While, the coagulant usage in the membrane filtration process was 43% lower than the sand filtration process. Thus, comparing the operation costs of the two processes, there is no significant difference in the operating cost of the membrane filtration process and the sand filtration process as $85.94KRW/m^3$ and $79.71KRW/m^3$ respectively (the sum of electricity and chemical cost). As a result of operating the membrane filtration process for 3 years including the winter season and the high turbidity period, the filtrated water turbidity was stable to less than 0.025 NTU irrespective of changes in the turbidity of raw water. And the CIP(Clean In Place) cycle turned out to be more than 1 year. Based on the results of this study, the membrane filtration process showed high performance of water quality, and it was also determined to have the economics and operation stability.

Development of Eco-Efficiency Indicators for Yeosu Industrial Park (여수산업단지의 생태효율성지표 개발에 관한 연구)

  • Kim, Jung-In;Yun, Chang-Han;Yoon, Hyung-Sun
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.229-237
    • /
    • 2010
  • The industrial ecology indicators(IEI) for Yeosu Industrial Park were developed using eco-efficiency indicator(EEI). The key factors for the creation of IEI were two parts. One part is the value of the products which is selected as the total production value, the amount of ethylene production, the amount of light oil production instead of the total sales volume for Yeosu Industrial Park, since the currency exchange and the price of raw materials varied every year. The other part is the environmental burden. The electric consumption, the industrial water consumption, and the amount of discharged waste water are all officially opened to the public, were used in the calculation. Based on the value for the year of 2004, the IEI value for 2006 became worse to 0.954, but, was expected to be 1.153, a 15% improvement, for 2015 if the current EIP project is successfully performed.