ERW 강관 용접부의 홈부식거동에 미치는 입열량의 영향 (The Effect of Heat Input on Grooving Corrosion Behavior in the Welds of Electric Resistance Welding Steel Pipe)

  • 이병우;이재식;박화순
    • 동력기계공학회지
    • /
    • 제11권3호
    • /
    • pp.41-46
    • /
    • 2007
  • The microstructure and electrochemical analysis of welds of electric resistance welding(ERW) pipe were investigated. The direction of metal flow line in HAZ of ERW pipe shifted to the inner(or outer) surface of pipe by plastic deformation during welding. The lowest heat input welds of ERW pipe was showed crack by liquid penetrant testing. Accelerated corrosion test by constant current density of 20mA/$cm^{2}$ developed groove at the welds of ERW pipe and the measured grooving factors were about $1.2{\sim}1.5$. Corrosion potential of base metal obtained by cyclic polarization in artificial sea water(3.5wt.% NaCl solution) was 100mV higher than that of weld metal of ERW pipe.

  • PDF

전기저항형 센서 및 전기화학적 방법을 이용한 철근콘크리트 구조물의 부식속도 측정 방법에 관한 연구 (Study on The Corrosion Rate Monitoring of Steel in Concrete Using Electric resistance Sensor and Electrochemical Methods.)

  • 조용범;김용철;장상엽;고영태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1185-1192
    • /
    • 2001
  • This paper reviews available techniques for monitoring corrosion of steel in concrete. The need for early detection and diagnosis of corrosion related deterioration in reinforced structures is widely acknowledged. This is particularly important in reinforced concrete structures on account of the economic and social significance of the problem. The current generally used on-site procedure for corrosion monitoring of reinforced structures employs a method of half-cell surface potential measurements. While the technique has provided a useful means of delineating areas of high or low corrosion risk, there are difficulties in its use and interpretation when assessing rates of deterioration. Electrochemical techniques are by far the most suitable for corrosion monitoring purpose and meet most of the requirements. The aim of this paper is to describe the electric resistance sensor(ER sensor) and electrochemical techniques employed to monitor and estimate corrosion rates of reinforcement. Early detection and diagnosis of corrosion hazards allows preventive measures to be taken, hence the typically expensive repair of severely deteriorated structures can be avoided.

  • PDF

전차선로 가선재의 수용액 부식 특성 (The Aqueous Corrosion Characteristics of Catenary Materials of Electric Railway System)

  • 김용기;장세기;조성일;이재봉
    • 한국철도학회논문집
    • /
    • 제4권2호
    • /
    • pp.62-70
    • /
    • 2001
  • Pure copper, Cu-1.1wt%Cd and ACSR(Aluminum Conductor Steel Reinforced) have been used as catenary materials of the electric railway system. Since these materials may be exposed to the corrosive environments like polluted air, acid rain and sea water, it is important to investigate the corrosion rates in various corrosive environments. The aqueous corrosion characteristics of catenary materials in aerated acid, neutral and alkali solutions were studied by using immersion corrosion tests, electrochemical measurements and analytical techniques. In order to examine corrosion characteristics according to the dissolved oxygen content, pH, chloride ion concentration ion, and the addition of Cd to Cu, a series of tests such as potentiodynamic polarization, a.c impedance spectroscopy and galvanic corrosion tests were carried out with these materials. Results showed that the addition of Cd to Cu and chloride ion in the solution have an adverse effects on the resistance to corrosion. Additionally, Galvanic currents between Al and steel wires of ACSR were confirmed by using ZRA(zero resistance ammeter) method.

  • PDF

귀선자동개폐장치를 이용한 차량기지 전식방지법 (Electrolytic Corrosion Protection Methods of Depots using Silicon Rectifier for the Rail)

  • 이현구;하윤철;하태현;최정희;김대경;배정효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.211-213
    • /
    • 2007
  • Current of DC traction systems flows from the positive busbar of the substation, through the overhead contact system, to the vehicle, and returns through the running rails. Because the rails are not very effectively insulated from the earth a certain amount of current flows into the earth, especially in the area near the load and depots. At the place where the stray current leaves the rail and pipe, corrosion may take place. In this paper we introduce the electrolytic corrosion protection methods of depots using silicon rectifier for the rail.

  • PDF

일정 변위 진폭조건에서의 은도금한 커넥터의 미동마멸부식 거동 (Fretting Corrosion Behavior of Silver-Plated Electric Connectors with Constant Displacement Amplitude)

  • 오만진;김민정;김택영;강세형;김호경
    • Tribology and Lubricants
    • /
    • 제30권2호
    • /
    • pp.99-107
    • /
    • 2014
  • Fretting corrosion tests are conducted with a constant displacement amplitude using silver-plated brass coupons to investigate the effect of contact pressure on fretting corrosion. Three behaviors are identified based on the change in electric resistance and friction coefficient during the fretting test period, and the identified behaviors are dependent on the magnitude of the applied load. The failure cycle ($N_f$) with an electric resistance of 0.1 D cannot be achieved due to the adhesion behavior of the metal and metal contact under the higher applied load of 0.45 N. This suggests that an average contact pressure higher than 159 MPa for the silver-coated connector is desirable to gain an almost infinite lifetime. The relationship between the electric contact resistance (R) and the average contact pressure (p) can be written as $p=106.2{\times}{\Omega}^{-1.5}$.

Synthesis of Polyamine Grafted Chitosan Copolymer and Evaluation of Its Corrosion Inhibition Performance

  • Li, Heping;Li, Hui;Liu, Yi;Huang, Xiaohua
    • 대한화학회지
    • /
    • 제59권2호
    • /
    • pp.142-147
    • /
    • 2015
  • Two new chitosan derivatives, polyamine grafted chitosan copolymers have been synthesized for corrosion protection of carbon steel in acidic medium. First, methyl acrylate graft chitosan copolymer (CS-MAA) was prepared by the reaction of chitosan (CS) and methyl acrylate (MAA) via the Michael addition reaction. Then, CS-MAA was reacted with ethylene diamine (EN) and triethylene tetramine (TN) respectively to synthesize ethylene diamine grafted chitosan copolymer (CS-MAA-EN) and triethylene tetramine grafted chitosan copolymer (CS-MAA-TN), and the structures were characterized by Fourier-transform infrared spectroscopy (FT-IR). At last, the corrosion inhibition activities on Q235 carbon steel were investigated by using gravimetric measurements, metallographic microscope, potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) measurements. The compounds CS-MAA-EN and CS-MAA-TN show an appreciable corrosion inhibition property against corrosion of Q235 carbon steel in 5% HCl solution at $25^{\circ}C$. It has been observed that CS-MAA-EN shows greater corrosion inhibition efficiency than CS-MAA-TN. The inhibition efficiency of CS-MAA-EN was close to 90% when the mass fraction concentration was 0.2%~0.3%; the inhibition efficiency of CS-MAA-TN was close to 85% when the mass fraction concentration was 0.02%. The present work provided very promising results in the preparation of green corrosion inhibitors.

주석 도금한 전기 접촉부의 미동마멸 부식에 대한 윤활유의 영향 (Effects of Lubricant on Fretting Corrosion of Tin-Coated Electric Contacts)

  • 김광수;오만진;한동운;김호경
    • Tribology and Lubricants
    • /
    • 제32권3호
    • /
    • pp.88-94
    • /
    • 2016
  • We conduct a series of fretting corrosion tests on tin-coated electric contact to evaluate the effects of lubricant on fretting corrosion behavior. We perform these tests with a constant contact force at 25℃ 50℃, 75°C, and 100℃. In the tests with a span amplitude of 30 μm, we could not determine the conventional behavior of the first, second, and third stages of the change in electric resistance during fretting corrosion and observed that the contact resistance continuously increases with the cycles. This behavior is due to the fact that the generation of oxides on the tin-coated contact is controlled and stabilized by the presence of lubricant. SEM observations on samples with a span amplitude of 77 μm at all testing temperatures confirm that there is less oxide debris on the fretting damaged surface. Hence, for tin-coated electric connector, the effect of lubrication on the lifetime of the electric contact increases as the fretting span decreases and testing temperature increases, compared to those for connector without lubricant. Especially, for a specimen with a span amplitude of 30 μm at 100℃, the increment in contact lifetime due to lubricant is found to be more than 20 times, compared to that without lubricant.

The influence of EAF dust on resistivity of concrete and corrosion of steel bars embedded in concrete

  • Almutlaq, Fahad M.
    • Advances in concrete construction
    • /
    • 제2권3호
    • /
    • pp.163-176
    • /
    • 2014
  • Essentially, when electrical current flows easily in concrete that has large pores filled with highly connective pore water, this is an indication of a low resistivity concrete. In concrete, the flow of current between anodic and cathodic sites on a steel reinforcing bar surface is regulated by the concrete electrical resistance. Therefore, deterioration of any existing reinforced concrete structure due to corrosion of reinforcement steel bar is governed, to some extent, by resistivity of concrete. Resistivity of concrete can be improved by using SCMs and thus increases the concrete electrical resistance and the ability of concrete to resist chloride ingress and/or oxygen penetration resulting in prolonging the onset of corrosion. After depassivation it may slow down the corrosion rate of the steel bar. This indicates the need for further study of the effect of electric arc furnace dust (EAFD) addition on the concrete resistivity. In this study, concrete specimens rather than mortars were cast with different additions of EAFD to verify the electrochemical results obtained and to try to understand the role of EAFD addition in influencing the corrosion behaviour of reinforcing steel bar embedded in concrete and its relation to the resistivity of concrete. The results of these investigations indicated that the corrosion resistance of steel bars embedded in concrete containing EAFD was improved, which may link to the high resistivity found in EAFD-concrete. In this paper, potential measurements, corrosion rates, gravimetric corrosion weight results and resistivity measurements will be presented and their relationships will also be discussed in details.

A New Technology of Anti-corrosive of Metals in Atmospheric Environment

  • Chen, Ke Zhong
    • Corrosion Science and Technology
    • /
    • 제2권4호
    • /
    • pp.194-196
    • /
    • 2003
  • In this paper, a newest kind of anti-atmospheric corrosion method is introduced. This method does not adopt organic coating, plastic layer or metal plating, instead it adopts a kind of aqueous emulsion containing numerous tine solid compounds that are absorbed onto the component surface, which play the role of anti-electrochemical corrosion.

산성비 환경을 모사한 수용액에서 염화물 농도에 따른 전기자동차 배터리 하우징용 재료의 전기화학적 특성 연구 (Investigation on Electrochemical Characteristics of Battery Housing Material for Electric Vehicles in Solution Simulating an Acid Rain Environment with Chloride Concentrations)

  • 신동호;김성종
    • Corrosion Science and Technology
    • /
    • 제21권2호
    • /
    • pp.147-157
    • /
    • 2022
  • Electrochemical characteristics and damage behavior of 6061-T6 aluminum alloy used as a battery housing material for electric vehicles were investigated in solution simulating the acid rain environment with chloride concentrations. Potentiodynamic polarization test was performed to analyze electrochemical characteristics. Damage behavior was analyzed through Tafel analysis, measurement of damage area, weight loss, and surface observation. Results described that corrosion current density was increased rapidly when chloride concentration excceded 600 PPM, and it was increased about 7.7 times in the case of 1000 PPM compared with 0 PPM. Potentiodynamic polarization experiment revealed that corrosion damage area and mass loss of specimen increased with chloride concentrations. When chloride concentration was further increased, the corrosion damage area extended to the entire surface. To determine damage tendency of pitting corrosion according to chloride concentration, the ratio of damage depth to width was calculated. It was found that the damage tendency decreased with chloride concentrations. Thus, 6061-T6 aluminum alloy damage becomes larger in the width direction than in the depth direction when a small amount of chloride is contained in an acid rain environment.