• 제목/요약/키워드: Electric Charge-discharge

검색결과 241건 처리시간 0.025초

리튬 폴리머 전지용 Flyash 부극의 충방전 특성 (Charge/discharge Properties of Flyash as a Anode for Lithium Polymer Battery)

  • 송희웅;김종욱;박계춘;구할본
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.968-970
    • /
    • 1999
  • The trend of increasing of portable electric devices and demand for global environmental conservation have demands the development of high energy density rechargeable batteries. Lithium polymer battery has excellent theoretical energy density and energy conversion efficiency. Lithium polymer battery, included solid polymer electrolyte(SPE), can be viewed as a system suitable for wide applications from thin film batteries for microelectronics to electric vehicle batteries. The purpose of this paper is to research and development of flyash anode for lithium polymer battery. We investigated AC impedance response and charge/discharge characteristics of flyash/SPE/Li cells. The radius of semicircle associated with the interfacial resistance of flyash/SPE/Li cell increased very slowly during discharge process from 3.11V to 0.478V. And then the cell resistance was decreased at discharge process from 10% SOC to 0% SOC. Also, The radius of semicircle associated with the interfacial resistance of flyash/SPE/Li cell decreasing very slowly during charge process. And then the cell resistance was increased after 20th discharge precess. The discharge capacity based on flyash of 1st and 20th cycles was 276mAh/g and 143mAh/g.

  • PDF

EPR의 열화에 의한 충.방전 전류 특성에 관한 연구 (A Study on Properties of Charge & Discharge Current by Degrade in EPR)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제21권7호
    • /
    • pp.679-685
    • /
    • 2008
  • This paper describes the degraded properties of between the charge and discharge current for ${\gamma}$-ray irradiated in electric power cable rubbers using in nuclear power generating station. The charge and discharge current of degradation in EPR(Ethylene Propylene Rubber), which were irradiated with the radiant capacity of 0.033 Mrad/h, have been measured in order to investigate the influence of the atmosphere(in amount of reinforcing agent, moisture absorption and heat treatment) on electrical properties. When ${\gamma}$-ray were irradiated on the EPR with more reinforcing agent from 4 to 40 Phr, charge and discharge currents was increase due to the amount of reinforcing agent. It was verified that the discharging and charging currents irradiated by ${\gamma}$-ray were higher than those that was not irradiated. The amount of the degraded current was more after moisture absorption than before moisture absorption. The charge and discharge current after heat treatment was similar to that of before heat treatment and it was decreased with the time elapsed. As these properties related with ${\gamma}$-ray irradiation dose, it is suggested that these properties can be utilized as a index of irradiation degradation.

방전현상 해석을 위한 전자장 및 전하이동 방정식의 비선형 결합 알고리즘 (Electric Discharge Analysis Using Nonlinarly-Coupled Equation of Electromagnetic Field and Charge Transport)

  • 이세연;박일한;이세희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1494-1495
    • /
    • 2006
  • A complete finite element analysis method for discharge onset process, which is governed and coupled by charge transport equation and electric field equation, was presented. The charge transport equation of first order was transformed into a second-order one by utilizing the artificial diffusion scheme. The two second-order equations were analyzed by the finite element formulation which is well-developed for second-order ones. The Fowler-Nordheim injection boundary condition was adopted for charge transport equation. After verifying the numerical results by comparing to the analytic solutions using parallel plane electrodes with one carrier system, we extended the result to blade-plane electrodes in 2D xy geometry with three carriers system. Radius of the sharp tip was taken to be 50 ${\mu}m$. When this sharp geometry was solved by utilizing the space discretizing methods, the very sharp tip was found to cause a singularity in electric field and space charge distribution around the tip. To avoid these numerical difficulties in the FEM, finer meshes, a higher order shape function, and artificial diffusion scheme were employed.

  • PDF

VRFB-ESS용 전해질의 이온가수 분석방법 및 SOC 분석 (Analysis of Vanadium Ions and SOC in the Electrolytes of VRFB-ESS)

  • 서혜경;박원식;김강산
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권2호
    • /
    • pp.309-316
    • /
    • 2021
  • For the detection of the state of charge in VRFB-ESS, the analyses of UV-Visible spectrometry and the measurements of potential between the anolyte and catholyte were used in parallel. This paper includes the production of 4-valant ion from VOSO4 powder, 3- and 5-valant ions from electrochemical charge of 4-valant ion and 2-valant ion from 3-valant ion. It also includes the analyses of these valance ions and unknown electrolyte at any time using UV-Visible spectrometry. Through the analyses of the valance ions in samples, the SOCs of the samples at any charge-discharge times were verified.

EDLC를 위한 성능시험용 충방전기 개발 (Development of Charger/Discharger to Test Performance for EDLC)

  • 김금수;문종현;조현철;김동희
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.16-22
    • /
    • 2012
  • With the increase of consumption of new renewable energy, the use of Electric Double Layer Capacitor(EDLC) is being gradually widened as the next generation energy storage device. In order to expand the market of EDLC which is recently receiving a lot of attraction as a new promising area, development of a charge/discharge cycle tester to measure and test performance, is essential. Therefore, this research designed a circuit to measure capacity and internal resistance and a circuit to measure voltage maintenance properties, based on EDLC's basic charging/discharging properties so it is able to measure the state of charge and discharge at high speed. When evaluating performance characteristics, the 5[V]/100[A] prototype-EDLC charge/discharge testing system developed for this research showed ${\pm}0.1$[%] of accuracy of voltage and current measurement. It was also proved that the developed charge/discharge testing system for EDLC can be applied to the actual industry, when testing the entire system using a program produced for data monitoring and acquisition.

부분방전 전자파 측정용 광대역 주파수 분석 시스템 개발 (The Development of wide frequency analyzing system by partial electric discharge electromagnetic-wave Receiver)

  • 박두용;신영진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.547-549
    • /
    • 2004
  • This system is monitors the degree of aging happened at the electric machine. It detects electromagnetic wave generated from the insulator when the voltage is applied to the machine. By analyzing the internal and external factors make the electric, mechanic, or thermal characteristics of the electric machinery deteriorate the electric insulation and eventually cause the partial electric discharge. The continuous partial electric charge accelerates the insulation aging and the insulation breakdown happens at last. This system consists of the relays connected with 10 sensors (40 total) detecting the partial electric discharge ans the temperature, the server, ans the program analyzing and storing the data.

  • PDF

표면 방전형 AC PDP의 셀 구조와 방전특성의 상관관계에 관한 연구 (A Study on the Relationship between Cell Structure and Discharge Characteristics of Surface Discharge AC PDP)

  • 신중홍;이우근;김준호;김규섭;유충희;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.133-140
    • /
    • 1999
  • The relationships between discharge characteristics and sustain electrode shape are studied in AC PDP by calculating the electric field and measuring discharge voltage, luminance and current. The maximum electric field is obtained for the triangle shape electrode. It is 1.8 times larger than uniform electric field type. It has been shown thatthe firing voltage is largely affected by the degree of electric field concentration. But, as the difference of the maximum and minimum value of electric field in a cell increases, the luminance and luminance efficiency decrease. And, the charge variation during discharge is proportional to the area of electrode.

  • PDF

A New Type of Nonthermal Plasma Reactor

  • Geum, Sang-Taek;Moon, Jae-Duk;Jun, Sun-Gon
    • The Korean Journal of Ceramics
    • /
    • 제5권3호
    • /
    • pp.245-249
    • /
    • 1999
  • A new type of nonthermal plasma reactor utilizing ferroelectric pellets is proposed to generate nonthermal plasma efficiently, which is used for simultaneous control of various pollutant gases. Electric charges stored on ferroelctric pellets by corona discharge between a corona tip and a mesh electrode provide partial electrical discharges among ferroelectric pellets. These partial electrical discharges can enhance partial discharges around the surface of ferroelectric pellets. This method utilizes wide reacting area of ferroelectric pellets and partial discharge. Positive and negative dc voltage are applied to the corona tip to generate partial discharges, and corona currents are estimated to investigate charge storage on ferroelectric pellets as function of time and charge relaxation time constants of ferroelectric pellects. As a result, charge relaxationtime, dielectric constants of ferroelectric pellets, polarity of applied voltage and applied time influence partial discharges among ferroelectric pellect.

  • PDF

절연진단을 위한 기중방전에서의 방사전자파 측정과 분석 (The Measurement and Analysis The Electromagnetic Wave by Discharge in Air for Insulation Diagnosis)

  • 이상훈;이현동;이춘하;윤영대;김기채;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.141-144
    • /
    • 1999
  • This paper offer fundamental ones about insulation diagnosis with electromagnetic wave, when discharges occurred. To simulate Partial-Discharge(PD), It is used needle-plane electrode in air. As the voltages applied, measure the electromagnetic wave with monopole antenna and analysis its fundamental characteristics, then, acquired data were operated. The results presented as the form of graph, and the magnitude of charge when occurred PD simultaneously. In conclusion, when the magnitude of charge over 100[pC], the electric field strength changed, and then the magnitude of charge and the electric field strength increased samely.

  • PDF

2단 평행판 전기집진기의 방전부 특성 실험 (Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner)

  • 김익생;이재옥;김용진;최헌오
    • 설비공학논문집
    • /
    • 제5권1호
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF