• Title/Summary/Keyword: Electric Bus

Search Result 319, Processing Time 0.027 seconds

A Study on the Circuit Breaker Transient Recovery Voltages on Large Commercial Customer using EMTP-RV Program (EMTP-RV를 이용한 대용량 전기설비의 차단기 TRV에 관한 연구)

  • Cho, Kyeh-Sool;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.59-66
    • /
    • 2011
  • In electric power system, the circuit breaker is not operated when the higher voltage then the rated TRV(transient Recovery Voltage) appeared in the circuit breaking, The TRV of a circuit breaker means the characteristics of reignition by the arc between two poles. and is decided by the value of connecting Impedance. In this paper we of carried out many kinds of experiments varying the types of bus, the types of installation, the length of installation between 22.9 [kV] level circuit breaker and MTR in general 154/22.9[kV] system, We also simulated the characteristics of TRV using EMTP-RV program. The suitability of TRV in assessed by Uc, RRRV(Rate of Rise of Recovery Voltage) which are defined by the international guide, IEC62271-100. The values of RRRV gained from the cable-made bus are 590[%] lesser than those from the NSPB-made bus respectively. So the triangled type is more rational in the aspect of TRV.

Process Optimization for Life Extension of Electropolishing Solution using Half Round Bus Bar (반구형 부스바를 이용한 전해연마액 수명연장을 위한 공정 최적화)

  • Kim, Soo Han;Lee, Seung Heon;Cho, Jaehoon;Lim, Dong-Ha;Choi, Joongso;Park, Chulhwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.5
    • /
    • pp.447-453
    • /
    • 2016
  • In this study, we intended to extend the life of electropolishing solution through the reduction of electric resistance by improving the electrolysis efficiency. The optimum conditions were obtained by half round bus bar and Taguchi method. As the main control factors in the electropolishing process, current density, polishing time, electrolyte temperature and flow rate were selected. The electrolyte temperature was the most significant to the electrolysis efficiency. The optimum conditions for the life extension of electropolishing solution were as follows: current density, $45A/dm^2$; polishing time, 6 min; electrolyte temperature, $70^{\circ}C$; flow rate, 11 L/min. As a results of ANOVA of SN ratios, it was found that the electrolyte temperature was significant factor at the 90% confidence level.

Comparison of Fault Current Limiting Characteristics According to Facility in Power System (전력계통의 사고전류 저감 설비별 특성 비교)

  • Park, Hyoung-Min;Choi, Hyo-Sang;Cho, Yong-Sun;Lim, Sung-Hun;Hwang, Jong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.127-129
    • /
    • 2005
  • We investigated the fault current limiting characteristics according to the various facilities in power system. Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such as short circuits are increasing higher, which causes the ratings of circuit breakers(CBs) to increase. Upgrading or replacement of CBs is not difficult from the technical and economical point of view. Bus split is being adopted into a part of 154 kV power systems, but it has adverse effects such as overload to neighboring power systems, increased voltage fluctuation, and decreased power system stability. For 345 kV power systems, the bus split measure is not feasible and dc reactors are being suggested. The superconducting fault current limiter is a protection gear of new concept that limits fault current automatically in a few milliseconds. It can also provide the effect of CB capacity increase, relaxation of power machine criteria, enhancement in power system reliability, and flexible power system operation.

  • PDF

Current Status of Hydrogen Consumption and Promotion Plan for the Deployment of Fuel Cell Bus in Changwon City (창원시 수소버스 운행에 따른 수소소비 현황 및 보급 활성화 방안)

  • KANG, BOO MIN;KANG, YOUNG TAEC;KIM, MIN WOO;LEE, SANG HYUN;PARK, MIN-JU;JEONG, CHANG-HOON;JEONG, DAE-WOON
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.6
    • /
    • pp.479-484
    • /
    • 2019
  • Environmental problems were related to human life from second industrial revolution. Recently, peoples are interested in solving global warming problem and improving air quality. Therefore, we request for eco-friendly vehicles such as fuel cell electric vehicles using eco-friendly hydrogen energy. In order to reduce particulate matter in Korea, we have established a plan to promote the deployment of eco-friendly vehicles. In this paper, we analyzed the average monthly charging status and hydrogen consumption by introducing fuel cell bus.

Development of a Flash Memory Drive for ATA bus (ATA 버스 방식을 위한 Flash Memory Drive 개발)

  • Kang, Kyung-Sik;Jang, Moon-Kee;Hwang, Yeon-Bum;Jung, Nam-Mo;Park, Jin-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.547-550
    • /
    • 2005
  • This treatise studies and developed flash memory drive of ATA bus that use flash memory which is employment amount memory semiconductor to improve problem of hard-disk that is existing ATA bus. While general hard-disk is sensitive external impact or shock, but flash memory drive do save chapter as well as is strong in external impact using semiconductor memory element that disk is not low electric power, light weight possible . Practical use is expected do save chapter for embedded system or black box for vehicles, soldiers hereafter therefore.

  • PDF

Three-Port Converters with a Flexible Power Flow for Integrating PV and Energy Storage into a DC Bus

  • Cheng, Tian;Lu, Dylan Dah-Chuan
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1433-1444
    • /
    • 2017
  • A family of non-isolated DC-DC three-port converters (TPCs) that allows for a more flexible power flow among a renewable energy source, an energy storage device and a current-reversible DC bus is introduced. Most of the reported non-isolated topologies in this area consider only a power consuming load. However, for applications such as hybrid-electric vehicle braking systems and DC microgrids, the load power generating capability should also be considered. The proposed three-port family consists of one unidirectional port and two bi-directional ports. Hence, they are well-suited for photovoltaic (PV)-battery-DC bus systems from the power flow viewpoint. Three-port converters are derived by combining different commonly known power converters in an integrated manner while considering the voltage polarity, voltage levels among the ports and the overall voltage conversion ratio. The derived converter topologies are able to allow for seven different modes of operation among the sources and load. A three-port converter which integrates a boost converter with a buck converter is used as a design example. Extensions of these topologies by combining the soft-switching technique with the proposed design example are also presented. Experiment results are given to verify the proposed three-port converter family and its analysis.

Efficiency Analysis for Differential Power Processing Converter Configurations in Photovoltaic Electric Vehicles (태양광 발전차량의 차동전력 조절기 배열에 따른 효율분석)

  • Kwon, Kyoungjun;Kim, Katherine A.
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.215-216
    • /
    • 2016
  • 최근 전기자동차(EV)의 수요가 높아짐에 따라, 그와 관련된 연구가 많이 진행되고 있다. 특히 기존 EV dc-bus에 쉽게 결합할 수 있는 photovoltaic-전기자동차(PV-EV)의 개발이 진행되었지만, 낮은 시스템 효율로 인해 상용화에 어려움을 겪었다. PV-EV의 특성상 태양광 시스템이 불균일한 태양빛의 변화에 노출되기 때문에, 차동전력 조절기(differential power processing (DPP) 컨버터)가 없는 기존의 시스템에서는 시스템 효율이 매우 저하된다. 이러한 문제점을 해결하기 위해, 본 연구에서 차동전력 조절기가 적용된 PV-EV 시스템을 제안하였다. 본 논문에서는 차동전력 조절기 시스템의 새로운 배열인 DPP to Load 배열을 제안하며 기존의 차동전력 조절기 시스템 배열과 비교분석 하였다. 또한 각각의 차동전력 조절기 배열에서 태양빛의 세기, 보조 부하의 크기, 컨버터의 효율을 변화시키며 각 배열의 시스템 효율을 비교하였다. 주어진 대부분의 조건에서 가장 높은 시스템 효율을 보여준 배열은 Isolated bus 배열 이었다. 맑은 날, 모든 컨버터의 효율은 85%, 보조부하가 250 W라고 가정하였을 때, Isolated bus 배열은 가장 높은 시스템 효율인 74%의 효율을 나타내었다.

  • PDF

Study on Scoring of Hypoid Gear Set in Bus with Retarder (리타더 장착 버스 하이포이드 기어의 스코링에 관한 연구)

  • Yang, J.H.;Kim, Y.J.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.102-109
    • /
    • 2009
  • A retarder, as a supplementary brake system that is not friction-based, is frequently used in heavy-duty vehicles generally to slow the vehicles down on inclines. The electric retarder mainly used in a heavy-duty bus is generally placed between the transmission and the axle. The rotor inside the retarder system is attached to the axle. The operation of the retarder within a driven vehicle generates reverse torque due to coast driving force on hypoid gears in the differential gear system. By the reverse torque, scoring or scuffing on the hypoid gear teeth may directly occur. The scoring may be generated due to excessive contact stresses on the tooth surface. In this study, tooth contact stresses and contact patterns were analysed in order to investigate on the tooth scoring phenomenon using a finite element analysis program T900 in which the Hertzian contact stress formula was taken. Backlash, wear and surface finish were considered in the finite element simulation on the scoring.

  • PDF

Optimal Capacitor Placement Considering Voltage-stability Margin with Hybrid Particle Swarm Optimization

  • Kim, Tae-Gyun;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.786-792
    • /
    • 2011
  • The present paper presents an optimal capacitor placement (OCP) algorithm for voltagestability enhancement. The OCP issue is represented using a mixed-integer problem and a highly nonlinear problem. The hybrid particle swarm optimization (HPSO) algorithm is proposed to solve the OCP problem. The HPSO algorithm combines the optimal power flow (OPF) with the primal-dual interior-point method (PDIPM) and ordinary PSO. It takes advantage of the global search ability of PSO and the very fast simulation running time of the OPF algorithm with PDIPM. In addition, OPF gives intelligence to PSO through the information provided by the dual variable of the OPF. Numerical results illustrate that the HPSO algorithm can improve the accuracy and reduce the simulation running time. Test results evaluated with the three-bus, New England 39-bus, and Korea Electric Power Corporation systems show the applicability of the proposed algorithm.

Clustering of transmission system using the electrical distance (전기적 거리를 이용한 송전계통 클러스터링)

  • Hwang, Ho-Yoon;Kim, Hyun-Hong;Won, Jong-Jip;Park, Jong-Bae;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.591_592
    • /
    • 2009
  • For a similar price signal to local consumer, a regional clustering is important that can transfer a equal sign to the bus which has each different price on the basis of bus. If you take LMP and local information this method into consideration at the same time, and you give weight on neither one side, buses on a borderline can move on arbitrary. For solving this problem, in this paper will propose a clustering method to have applied new concept called 'electric distance'.

  • PDF